Abstract
Purpose Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study. Methods Patients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests. Results One hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV). Conclusion SyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.Keywords
This publication has 27 references indexed in Scilit:
- Electrocardiographic versus Echocardiographic Optimization of the Interventricular Pacing Delay in Patients Undergoing Cardiac Resynchronization TherapyJournal of Cardiovascular Electrophysiology, 2011
- The QRS Narrowing Index Predicts Reverse Left Ventricular Remodeling Following Cardiac Resynchronization TherapyPacing and Clinical Electrophysiology, 2011
- Agreement Is Poor Among Current Criteria Used to Define Response to Cardiac Resynchronization TherapyCirculation, 2010
- Midterm 'super-response' to cardiac resynchronization therapy by biventricular pacing with fusion: insights from electro-anatomical mappingEP Europace, 2009
- AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the ElectrocardiogramCirculation, 2009
- Clinical and electrocardiographic predictors of a positive response to cardiac resynchronization therapy in advanced heart failureEuropean Heart Journal, 2005
- QRS Duration and Shortening to Predict Clinical Response to Cardiac Resynchronization Therapy in Patients with End‐Stage Heart FailurePacing and Clinical Electrophysiology, 2004
- Effect of Cardiac Resynchronization Therapy on Left Ventricular Size and Function in Chronic Heart FailureCirculation, 2003
- Cardiac Resynchronization in Chronic Heart FailureThe New England journal of medicine, 2002
- Effects of Multisite Biventricular Pacing in Patients with Heart Failure and Intraventricular Conduction DelayThe New England journal of medicine, 2001