David O'DOnnell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David O'DOnnell has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- John Pius Bourke
Department of Cardiology, Freeman Hospital, Newcastle upon Tyne, UK
7 shared publications Steve S. Furniss
Freeman Hospital
4 shared publicationsKyungmoo Ryu
Abbott Sylmar California USA
3 shared publicationsBernard Thibault
Montreal Heart Institute, Montréal, Canada
2 shared publicationsCarlo Pappone
Department of Arrhythmology, I.R.C.C.S. Policlinico San Donato, San Donato Milanese, Italy
2 shared publicationsJan O. Mangual
Abbott Sylmar California USA
2 shared publications
Latest Publications
- 12 September 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (9)
Cover Image, Volume 32, Issue 9
- 12 September 2021
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (9)
Cover Image, Volume 32, Issue 9
- 28 July 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (10) , 1663-1670
Ventricular activation patterns during intrinsic conduction and right ventricular pacing in cardiac resynchronization therapy patients
Background: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV‐LV conduction is typically measured in intrinsic rhythm. The differences in RV‐LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood.Methods: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing.Results: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV‐LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra‐LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%.Conclusions: Differences in RV‐LV conduction time, intra‐LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.
- 28 July 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (10) , 1663-1670
Ventricular activation patterns during intrinsic conduction and right ventricular pacing in cardiac resynchronization therapy patients
Background: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV‐LV conduction is typically measured in intrinsic rhythm. The differences in RV‐LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood.Methods: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing.Results: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV‐LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra‐LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%.Conclusions: Differences in RV‐LV conduction time, intra‐LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.
- 1 August 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 61 (3) , 453-460
Electrical synchronization achieved by multipoint pacing combined with dynamic atrioventricular delay
Purpose Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study. Methods Patients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests. Results One hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV). Conclusion SyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.
- 1 August 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 61 (3) , 453-460
Electrical synchronization achieved by multipoint pacing combined with dynamic atrioventricular delay
Purpose Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed. The objective was to evaluate the improvement in electrical synchrony achieved by SyncAV combined with MPP in an international, multicenter study. Methods Patients with LBBB undergoing CRT implant with a quadripolar lead (Abbott Quartet™) were prospectively enrolled. QRS duration (QRSd) was measured by blinded observers from 12-lead ECG during: intrinsic conduction, BiV pacing (conventional biventricular pacing, nominal static AVD), MPP (2 LV cathodes maximally spaced, nominal static AVD), BiV + SyncAV, and MPP + SyncAV. All SyncAV offsets were individualized for each patient to yield the narrowest QRSd during BiV pacing. QRSd changes were compared by ANOVA and post hoc Tukey-Kramer tests. Results One hundred and three patients were enrolled (65.7 ± 12.1 years, 67% male, 37% ischemic, EF 26.4 ± 6.5%, PR 190.3 ± 39.1 ms). Relative to intrinsic conduction (QRSd of 165 ± 16 ms), BiV reduced QRSd by 11.9% to 145 ± 18 ms (P < 0.001 vs intrinsic), and MPP reduced QRSd by 13.3% to 142 ± 19 ms (P < 0.001 vs intrinsic). However, enabling SyncAV with a patient-optimized offset nearly doubled this QRSd reduction. BiV + SyncAV reduced QRSd by 22.0% to 128 ± 13 ms (P < 0.001 vs BiV), while MPP + SyncAV reduced QRSd further by 25.6% to 122 ± 14 ms (P < 0.05 vs BiV + SyncAV). Conclusion SyncAV can significantly improve acute electrical synchrony beyond conventional CRT, with further improvement achieved by superimposing MPP.
- 21 March 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (4) , euw039-595
Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents
Aims The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). Methods and results A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. Conclusion The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.
- 21 March 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 19 (4) , euw039-595
Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents
Aims The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). Methods and results A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. Conclusion The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.
- 10 September 2013
- Published by Wiley in Internal Medicine Journal
- Vol. 43 (11) , 1216-1223
Long-term clinical response to cardiac resynchronisation therapy under a multidisciplinary model
Background Cardiac resynchronisation therapy (CRT) is established in the management of cardiac failure in patients with systolic dysfunction. Clinical response to CRT is not uniform, and response has been difficult to predict. Aim Patient management within a high volume, multidisciplinary service focused on optimal delivery of CRT would improve response rates. Methods Four hundred and thirty‐five consecutive patients who underwent CRT under a multidisciplinary heart failure service were enrolled prospectively over a 5‐year period. Medically optimised, symptomatic patients with an ejection fraction (EF) 10% and an improvement in EF >5%. Results With a mean follow up of 53 ± 11 months, response rate to CRT was 81%. Mean EF improved from 26 ± 10% to 37 ± 11%, and mean left ventricular end‐diastolic diameter reduced from 68.6 ± 9.2 mm to 57.8 ± 9.3 mm. Predictors of response were sinus rhythm, high dyssynchrony index and intrinsic electrical dyssynchrony >80ms. Successful LV lead implantation at initial procedure was achieved in 99.1%, and at latest follow up 94.6% of initial LV leads were still active. Conclusion CRT undertaken with a unit focus on optimal LV lead positioning and device optimisation, along with a multidisciplinary follow‐up model, results in an excellent response rate to CRT.
- 10 September 2013
- Published by Wiley in Internal Medicine Journal
- Vol. 43 (11) , 1216-1223
Long-term clinical response to cardiac resynchronisation therapy under a multidisciplinary model
Background Cardiac resynchronisation therapy (CRT) is established in the management of cardiac failure in patients with systolic dysfunction. Clinical response to CRT is not uniform, and response has been difficult to predict. Aim Patient management within a high volume, multidisciplinary service focused on optimal delivery of CRT would improve response rates. Methods Four hundred and thirty‐five consecutive patients who underwent CRT under a multidisciplinary heart failure service were enrolled prospectively over a 5‐year period. Medically optimised, symptomatic patients with an ejection fraction (EF) 10% and an improvement in EF >5%. Results With a mean follow up of 53 ± 11 months, response rate to CRT was 81%. Mean EF improved from 26 ± 10% to 37 ± 11%, and mean left ventricular end‐diastolic diameter reduced from 68.6 ± 9.2 mm to 57.8 ± 9.3 mm. Predictors of response were sinus rhythm, high dyssynchrony index and intrinsic electrical dyssynchrony >80ms. Successful LV lead implantation at initial procedure was achieved in 99.1%, and at latest follow up 94.6% of initial LV leads were still active. Conclusion CRT undertaken with a unit focus on optimal LV lead positioning and device optimisation, along with a multidisciplinary follow‐up model, results in an excellent response rate to CRT.
- 1 January 2012
- Published by Wolters Kluwer Health in Current Opinion in Cardiology
- Vol. 27 (1) , 29-35
How much training is required to implant and manage CRT?
The number of patients receiving cardiac resynchronization therapies (CRTs) is increasing at a substantial rate. The implant, however, is not always performed effectively and the complication rates are considerable. The training and accreditation to perform CRT need to be evaluated to optimize procedural and patient outcomes. The relationship between higher procedural volumes and reduced procedural complications is evident and consistent across a range of surgical specialties and procedures. Present guidelines recommend that training in CRT can be achieved with five to 25 cases. The limited studies in this area suggest that this is inadequate, with complication rates of CRT reducing significantly with procedural experience well beyond 100 cases.There is increasing evidence that the development of procedural skills is dependent not only on cognitive factors, but also on a number of intrinsic visuospatial factors and fine motor dexterity. These factors can be tested objectively and the validity of adopting these techniques for the selection and training of operators is being evaluated. Ongoing evaluation of the training requirements and accreditation is required to optimize the implantation of CRT.
- 1 January 2012
- Published by Wolters Kluwer Health in Current Opinion in Cardiology
- Vol. 27 (1) , 29-35
How much training is required to implant and manage CRT?
The number of patients receiving cardiac resynchronization therapies (CRTs) is increasing at a substantial rate. The implant, however, is not always performed effectively and the complication rates are considerable. The training and accreditation to perform CRT need to be evaluated to optimize procedural and patient outcomes. The relationship between higher procedural volumes and reduced procedural complications is evident and consistent across a range of surgical specialties and procedures. Present guidelines recommend that training in CRT can be achieved with five to 25 cases. The limited studies in this area suggest that this is inadequate, with complication rates of CRT reducing significantly with procedural experience well beyond 100 cases.There is increasing evidence that the development of procedural skills is dependent not only on cognitive factors, but also on a number of intrinsic visuospatial factors and fine motor dexterity. These factors can be tested objectively and the validity of adopting these techniques for the selection and training of operators is being evaluated. Ongoing evaluation of the training requirements and accreditation is required to optimize the implantation of CRT.
- 31 January 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (s1) , S27-S30
Bifocal Right Ventricular Cardiac Resynchronization Therapies in Patients with Unsuccessful Percutaneous Lateral Left Ventricular Venous Access
Biventricular cardiac resynchronization therapy (CRT) with a lateral left ventricular (LV) lead cannot always be achieved. We report a single center experience of CRT utilizing a protocol that specifically required the implantation of a bifocal right ventricular (RV) lead system when lateral LV pacing could not be achieved. Consecutive candidates for CRT were included in the study. If strict criteria for lateral LV pacing were not met, they underwent implantation of a bifocal RV lead system with two 7F, active fixation leads, one placed septally at the apex, and the other in the high septal outflow tract. All patients were followed for 12 months and the two groups were compared. A biventricular (BiV) stimulation system was implanted in 44 patients, and a bifocal RV system in six. The demographic characteristics of the two groups were similar. Both groups experienced a similar improvement in functional capacity, increase in 6 minutes walking distance, and decreased need for hospitalizations. The mean increase in LV ejection fraction was 11% in the bifocal RV group versus 10% in the BiV group. Though the tissue Doppler indices of LV synchrony improved earlier in the BiV group, (19% vs 10%) the improvement was similar in both groups at 6 months (23% vs 20%). The clinical improvements conferred by CRT can be matched by a bifocal RV system in selected patients. This alternate approach should be considered when implantation of a LV lateral lead was unsuccessful.
- 31 January 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (s1) , S27-S30
Bifocal Right Ventricular Cardiac Resynchronization Therapies in Patients with Unsuccessful Percutaneous Lateral Left Ventricular Venous Access
Biventricular cardiac resynchronization therapy (CRT) with a lateral left ventricular (LV) lead cannot always be achieved. We report a single center experience of CRT utilizing a protocol that specifically required the implantation of a bifocal right ventricular (RV) lead system when lateral LV pacing could not be achieved. Consecutive candidates for CRT were included in the study. If strict criteria for lateral LV pacing were not met, they underwent implantation of a bifocal RV lead system with two 7F, active fixation leads, one placed septally at the apex, and the other in the high septal outflow tract. All patients were followed for 12 months and the two groups were compared. A biventricular (BiV) stimulation system was implanted in 44 patients, and a bifocal RV system in six. The demographic characteristics of the two groups were similar. Both groups experienced a similar improvement in functional capacity, increase in 6 minutes walking distance, and decreased need for hospitalizations. The mean increase in LV ejection fraction was 11% in the bifocal RV group versus 10% in the BiV group. Though the tissue Doppler indices of LV synchrony improved earlier in the BiV group, (19% vs 10%) the improvement was similar in both groups at 6 months (23% vs 20%). The clinical improvements conferred by CRT can be matched by a bifocal RV system in selected patients. This alternate approach should be considered when implantation of a LV lateral lead was unsuccessful.
- Open Access
- 1 April 2004
- Vol. 4 (2) , 63-72
Radiofrequency Ablation for Post Infarction Ventricular Tachycardia
Radiofrequency ablation has an important role in the management of post infarction ventricular tachycardia. The mapping and ablation of ventricular tachycardia (VT) is complex and technically challenging. In the era of implantable cardioverter defibrillators, the role of radiofrequency ablation is most commonly reserved as an adjunctive treatment for patients with frequent, symptomatic episodes of ventricular tachycardia. In this setting the procedure has a success rate of around 70-80% and a low complication rate. With improved ability to predict recurrent VT and improvements in mapping and ablation techniques and technologies, the role of radiofrequency ablation should expand further.
- 1 April 2004
- Vol. 4 (2) , 63-72
Open AccessRadiofrequency Ablation for Post Infarction Ventricular Tachycardia
Radiofrequency ablation has an important role in the management of post infarction ventricular tachycardia. The mapping and ablation of ventricular tachycardia (VT) is complex and technically challenging. In the era of implantable cardioverter defibrillators, the role of radiofrequency ablation is most commonly reserved as an adjunctive treatment for patients with frequent, symptomatic episodes of ventricular tachycardia. In this setting the procedure has a success rate of around 70-80% and a low complication rate. With improved ability to predict recurrent VT and improvements in mapping and ablation techniques and technologies, the role of radiofrequency ablation should expand further.
- 1 May 2003
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 24 (9) , 801-810
Clinical and electrophysiological differences between patients with arrhythmogenic right ventricular dysplasia and right ventricular outflow tract tachycardia
Radiofrequency catheter ablation is considered first line treatment for symptomatic patients with right ventricular outflow tract tachycardia (RVOT). The role of ablation in arrhythmogenic right ventricular dysplasia (ARVD) is more limited. As such, differentiating between the two conditions is essential. This study compared non-invasive findings, magnetic resonance images (MRI), invasive electrophysiological characteristics, results of ablation and long-term outcome in 50 consecutive patients with RVOT (33) or ARVD (17). Structural abnormalities were uniform in the ARVD group; in addition 18 (54%) of the RVOT tachycardia group had MRI abnormalities. At electrophysiological study the tachycardia in the ARVD group displayed features of re-entry in over 80%, but behaved with a triggered automatic basis in 97% with RVOT. Ablation was complete or partial success in 12 (71%) patients with ARVD and ventricular tachycardia (VT) recurred in eight (48%). In the RVOT patients, ablation was a complete success in 97% with recurrent VT in 6%. Long-term success in the RVOT patients was 95% in both patients with and without MRI abnormalities. Electrophysiological characterization can differentiate ARVD from RVOT. The finding of abnormalities on MRI does not have any bearing on arrhythmia mechanism, acute or long-term success of RFA.
- 1 May 2003
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 24 (9) , 801-810
Clinical and electrophysiological differences between patients with arrhythmogenic right ventricular dysplasia and right ventricular outflow tract tachycardia
Radiofrequency catheter ablation is considered first line treatment for symptomatic patients with right ventricular outflow tract tachycardia (RVOT). The role of ablation in arrhythmogenic right ventricular dysplasia (ARVD) is more limited. As such, differentiating between the two conditions is essential. This study compared non-invasive findings, magnetic resonance images (MRI), invasive electrophysiological characteristics, results of ablation and long-term outcome in 50 consecutive patients with RVOT (33) or ARVD (17). Structural abnormalities were uniform in the ARVD group; in addition 18 (54%) of the RVOT tachycardia group had MRI abnormalities. At electrophysiological study the tachycardia in the ARVD group displayed features of re-entry in over 80%, but behaved with a triggered automatic basis in 97% with RVOT. Ablation was complete or partial success in 12 (71%) patients with ARVD and ventricular tachycardia (VT) recurred in eight (48%). In the RVOT patients, ablation was a complete success in 97% with recurrent VT in 6%. Long-term success in the RVOT patients was 95% in both patients with and without MRI abnormalities. Electrophysiological characterization can differentiate ARVD from RVOT. The finding of abnormalities on MRI does not have any bearing on arrhythmia mechanism, acute or long-term success of RFA.
- 1 February 2003
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 8 (1) , 37-40
Dynamic Alterations in Right Atrial Activation During Atrial Fibrillation
Atrial fibrillation (AF) is usually considered to be a disorganized rhythm. However, several reports have described areas of organized right atrial (RA) activation during AF. We describe a patient...
- 1 February 2003
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 8 (1) , 37-40
Dynamic Alterations in Right Atrial Activation During Atrial Fibrillation
Atrial fibrillation (AF) is usually considered to be a disorganized rhythm. However, several reports have described areas of organized right atrial (RA) activation during AF. We describe a patient...