Improved dosimetric accuracy with semi‐automatic contour propagation of organs‐at‐risk in glioblastoma patients undergoing chemoradiation
Open Access
- 31 October 2019
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (12) , 45-53
Abstract
Background: We study the changes in organs‐at‐risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non‐deformable OAR changes and the accuracy and feasibility of semi‐automatic OAR contour propagation are investigated.Methods: Fourteen GBM patients who were treated with adjuvant CRT for GBM prospectively underwent MRIs on fractions 0 (i.e., planning), 10, 20, and 1 month post last fraction of CRT. Three sets of OAR contours — (a) manual, (b) rigidly registered (static), and (c) semi‐automatically propagated — were compared using Dice similarity coefficient (DSC) and Hausdorff distance (HD). Dosimetric impact was determined by comparing the minimum dose to the 0.03 cc receiving the highest dose (D0.03 cc) on a clinically approved reference, non‐adapted radiation therapy plan.Results: The DSC between the manual contours and the static contours decreased significantly over time (fraction 10: [mean ± 1 SD] 0.78 ± 0.17, post 1 month: 0.76 ± 0.17, P = 0.02) while the HD (P = 0.74) and the difference in D0.03cc did not change significantly (P = 0.51). Using the manual contours as reference, compared to static contours, propagated contours have a significantly higher DSC (propagated: [mean ± 1 SD] 0.81 ± 0.15, static: 0.77 ± 0.17, P < 0.001), lower HD (propagated: 3.77 ± 1.8 mm, static: 3.96 ± 1.6 mm, P = 0.002), and a significantly lower absolute difference in D0.03cc (propagated: 101 ± 159 cGy, static: 136 ± 243 cGy, P = 0.019).Conclusions: Nonrigid changes in OARs over time lead to different maximum doses than planned. By using semi‐automatic OAR contour propagation, OARs are more accurately delineated on subsequent fractions, with corresponding improved accuracy of the reported dose to the OARs.Keywords
Funding Information
- Elekta
This publication has 24 references indexed in Scilit:
- Patterns of failure for glioblastoma multiforme following limited-margin radiation and concurrent temozolomideRadiation Oncology, 2014
- Vision 20/20: Perspectives on automated image segmentation for radiotherapyMedical Physics, 2014
- State of the art survey on MRI brain tumor segmentationMagnetic Resonance Imaging, 2013
- Atlas-based automatic segmentation of head and neck organs at risk and nodal target volumes: a clinical validationRadiation Oncology, 2013
- Interfractional Variation of Radiation Target and Adaptive Radiotherapy for Totally Resected GlioblastomaJournal of Korean Medical Science, 2013
- Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Tumor regrowth between surgery and initiation of adjuvant therapy in patients with newly diagnosed glioblastomaNeuro-Oncology, 2009
- Atlas-Based Auto-segmentation of Head and Neck CT Images2008
- Evaluating changes in tumor volume using magnetic resonance imaging during the course of radiotherapy treatment of high-grade gliomas: Implications for conformal dose-escalation studiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Radiotherapy plus Concomitant and Adjuvant Temozolomide for GlioblastomaNew England Journal of Medicine, 2005