YLYoung Lee

Young Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Young Lee has a total of 217 co-authors. Here are the top co-authors by number of shared publications:

  • Arjun Sahgal

    Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada

    26 shared publications
  • Hany Soliman

    Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada

    14 shared publications
  • Chia-Lin Tseng

    Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Canada

    13 shared publications
  • Mark Ruschin

    Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada

    12 shared publications
  • Sten Myrehaug

    Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, University of Toronto, Toronto, ON, Canada

    12 shared publications
  • Mark Ruschin

    Sunnybrook Health Sciences Centre, Odette Cancer Centre

    10 shared publications

Latest Publications

  • Open Access

    Pregnancy, cancer, and radiation—a modern refresher

    by Kelly Kisling, Sandra M Meyers, Rebecca Milman, Susan Richardson, Christina Chapman, Justine Dupere, Grace Eliason, Suzanne Evans, Titania Juang, Young Lee, et al.

    Cancer occurs in ∼1 per 1000 pregnancies; thousands of patients may require radiation procedures for diagnosis and treatment each year in the United States alone. This rare but high-risk scenario, coupled with fear of radiation, has created ambiguity in the ideal management of pregnant patients. Without a comprehensive guide for the use of radiation in imaging and treatment for pregnant cancer patients, it is difficult for providers to offer optimal patient-centered care without introducing disparities. The goal of this paper is to provide guidance on the use of radiation for screening, diagnosis, staging, and treatment of cancer, while highlighting gaps in existing knowledge and guidelines. The intention is that physicians, medical physicists, and patients could use this document as a resource for shared decision-making, ensuring safe and effective practice. A team of physicians and medical physicists with expertise in imaging, radiotherapy, and maternal fetal medicine was assembled, along with a patient advocate and lawyer. Existing guidelines and recent literature were reviewed. Authors also drew from their experience where published guidance was lacking. The resulting document discusses best practice to guide use of radiation for cancer, as well as patient-centered care management and legal considerations. Overall, it is possible to safely and effectively deliver radiation to pregnant patients in numerous circumstances. Use of radiation or other modalities should be discussed through shared decision-making with the physician and patient, contextualizing the maternal and fetal risk from treatments. Healthcare providers should support wide access to reproductive healthcare to allow equitable, evidence-based, patient-centered healthcare.


  • Open Access

    Quantifying the Sensitivity of Target Dose on Intrafraction Displacement in Intracranial Stereotactic Radiosurgery

    by Jannie Schasfoort, Mark Ruschin, Arjun Sahgal, R. Lee MacDonald, Young Lee, Carola van Pul, Patrick Langenhuizen, Patrick Hanssens, Guus Beute, Frits Wittkamper, et al.


  • Open Access

    A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment

    by Jiwon Lee, Younggeun Cho, Han-Sung Kim, Hee Jung Kang, Miyoung Kim, Young Kyung Lee

    We evaluated the capacity of the XN-350 instrument to analyze 3 different types of body fluid samples under “body fluid mode.” The performance of XN-350 was evaluated in terms of precision, carryover, limit of blank, limit of detection, limit of quantification, and linearity. Cell enumeration and differential data produced by the XN-350 were compared to manual chamber counting results in 63 cerebrospinal fluid (CSF), 51 ascitic fluid, and 51 pleural fluid (PF) samples. Comparisons between XN-350 versus Cytospin data were also performed in PF samples. The precision, carry-over, limit of blank, and linearity of the XN-350 were acceptable. The limits of detection for white blood cells (WBCs) and red blood cells were 1.0/μL, and 1,000.0/μL, respectively; the corresponding limits of quantitation (LOQs) were 5.0/μL and 2,000.0/μL, respectively. The XN-350's cell enumeration and differential counting correlated well with those of manual chamber counting for all 3 sample types (except for differential counting in CSF samples), particularly parameters involving monocytes (r = 0.33) and mononuclear cells (MO- body fluid [BF]; r = 0.26), as well as total cell (TC-BF) enumeration (r = 0.50) and WBC-BF (r = 0.50) in PF samples. The MO-BF in CSF samples differed significantly from manual chamber counting results, but neither TC-BF nor WBC-BF in PF samples did. The XN-350 also showed good correlations with Cytospin analyses for differential counting of neutrophils, lymphocytes, and monocytes in PF samples. The differential counting of eosinophils via the XN-350 and Cytospin were not significantly correlated, but the difference between them was not significant. The XN-350 is an acceptable alternative to manual fluid analysis. Samples with low cellularity around the LOQ should be checked manually. Moreover, manual differential counting should be performed on CSF samples, particularity those with low cell numbers.


  • Dosimetric comparison of two treatment planning systems for spine SBRT

    by Young Kyung Lee, Iram Munawar, Shahram Mashouf, Arjun Sahgal, Mark Ruschin


  • Open Access

    Technical Principles of Dual-Energy Cone Beam Computed Tomography and Clinical Applications for Radiation Therapy

    by Shailaja Sajja, Young Lee, Markus Eriksson, Håkan Nordström, Arjun Sahgal, Masoud Hashemi, James G. Mainprize, Mark Ruschin


  • Open Access

    Improved dosimetric accuracy with semi‐automatic contour propagation of organs‐at‐risk in glioblastoma patients undergoing chemoradiation

    by Sangjune Lee, James Stewart, Young Lee, Sten Myrehaug, Arjun Sahgal, Mark Ruschin, Chia‐Lin Tseng

    Background: We study the changes in organs‐at‐risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non‐deformable OAR changes and the accuracy and feasibility of semi‐automatic OAR contour propagation are investigated.Methods: Fourteen GBM patients who were treated with adjuvant CRT for GBM prospectively underwent MRIs on fractions 0 (i.e., planning), 10, 20, and 1 month post last fraction of CRT. Three sets of OAR contours — (a) manual, (b) rigidly registered (static), and (c) semi‐automatically propagated — were compared using Dice similarity coefficient (DSC) and Hausdorff distance (HD). Dosimetric impact was determined by comparing the minimum dose to the 0.03 cc receiving the highest dose (D0.03 cc) on a clinically approved reference, non‐adapted radiation therapy plan.Results: The DSC between the manual contours and the static contours decreased significantly over time (fraction 10: [mean ± 1 SD] 0.78 ± 0.17, post 1 month: 0.76 ± 0.17, P = 0.02) while the HD (P = 0.74) and the difference in D0.03cc did not change significantly (P = 0.51). Using the manual contours as reference, compared to static contours, propagated contours have a significantly higher DSC (propagated: [mean ± 1 SD] 0.81 ± 0.15, static: 0.77 ± 0.17, P < 0.001), lower HD (propagated: 3.77 ± 1.8 mm, static: 3.96 ± 1.6 mm, P = 0.002), and a significantly lower absolute difference in D0.03cc (propagated: 101 ± 159 cGy, static: 136 ± 243 cGy, P = 0.019).Conclusions: Nonrigid changes in OARs over time lead to different maximum doses than planned. By using semi‐automatic OAR contour propagation, OARs are more accurately delineated on subsequent fractions, with corresponding improved accuracy of the reported dose to the OARs.


  • Open Access

    Single-Fraction Stereotactic Radiosurgery Versus Hippocampal-Avoidance Whole Brain Radiation Therapy for Patients With 10 to 30 Brain Metastases: A Dosimetric Analysis

    by Timothy K. Nguyen, Arjun Sahgal, Jay Detsky, Hany Soliman, Sten Myrehaug, Chia-Lin Tseng, Zain A. Husain, Anne Carty, Sunit Das, Victor Yang, et al.


  • Postoperative Stereotactic Body Radiotherapy for Spinal Metastases and the Impact of Epidural Disease Grade

    by Majed Alghamdi, Arjun Sahgal, Hany Soliman, Sten Myrehaug, Victor X D Yang, Sunit Das, Jefferson Wilson, Mikki Campbell, Young K Lee, Monica Cawricz, et al.

    BACKGROUND: Postoperative stereotactic body radiotherapy (pSBRT) is an emerging indication for spinal metastases (SM). OBJECTIVE: To report our experience with pSBRT for SM. METHODS: A retrospective chart review was performed for prospectively collected data of patients treated between September 2008 to December 2015 with pSBRT and followed with serial spinal MRIs every 2 to 3 mo until death or last follow-up. Univariate and multivariable analyses were performed to identify predictive factors. RESULTS: A total of 83 spinal segments in 47 patients treated with a median dose of 24 Gy in 2 fractions were included, with mostly lung and breast primaries. A total of 59.3% had preoperative high-grade epidural disease (ED) and 39.7% were unstable. The 12-mo cumulative incidence of local failure was 17% for all segments, and 33.3%, 21.8%, and 0% in segments with postoperative high-grade, low-grade, and no ED, respectively. Downgrading preoperative ED was predictive of better local control (P = .03). The grade of postoperative ED was also predictive for local control (P < .0001), as was a longer interval between prior radiotherapy and pSBRT in those previously irradiated (P = .004). The 12-mo overall survival rate was 55%. One case of radiculopathy, 3 vertebral compression fractures, and no cases of myelopathy, hardware failure, or skin breakdown were observed. CONCLUSION: pSBRT is an effective and safe treatment. The association between downgrading preoperative ED and better local control following pSBRT is confirmed and supports the concept of separation surgery.


  • Open Access

    Tissue segmentation‐based electron density mapping for MR‐only radiotherapy treatment planning of brain using conventional T1‐weighted MR images

    by Huan Yu, Michael Oliver, Konrad Leszczynski, Young Lee, Irene Karam, Arjun Sahgal

    Purpose: Magnetic resonance imaging (MRI) is the primary modality for targeting brain tumors in radiotherapy treatment planning (RTP). MRI is not directly used for dose calculation since image voxel intensities of MRI are not associated with EDs of tissues as those of computed tomography (CT). The purpose of the present study is to develop and evaluate a tissue segmentation‐based method to generate a synthetic‐CT (sCT) by mapping EDs to corresponding tissues using only T1‐weighted MR images for MR‐only RTP.Methods: Air regions were contoured in several slices. Then, air, bone, brain, cerebrospinal fluid (CSF), and other soft tissues were automatically segmented with an in‐house algorithm based on edge detection and anatomical information and relative intensity distribution. The intensities of voxels in each segmented tissue were mapped into their CT number range to generate a sCT. Twenty‐five stereotactic radiosurgery and stereotactic ablative radiotherapy patients’ T1‐weighted MRI and coregistered CT images from two centers were retrospectively evaluated. The CT was used as ground truth. Distances between bone contours of the external skull of sCT and CT were measured. The mean error (ME) and mean absolute error (MAE) of electron density represented by standardized CT number was calculated in HU.Results: The average distance between the contour of the external skull in sCT and the contour in coregistered CT is 1.0 ± 0.2 mm (mean ± 1SD). The ME and MAE differences for air, soft tissue and whole body voxels within external body contours are −4 HU/24 HU, 2 HU/26 HU, and −2 HU/125 HU, respectively.Conclusions: A MR‐sCT generation technique was developed based on tissue segmentation and voxel‐based tissue ED mapping. The generated sCT is comparable to real CT in terms of anatomical position of tissues and similarity to the ED assignment. This method provides a feasible method to generate sCT for MR‐only radiotherapy treatment planning.