An Intraoperative $\beta ^{-}$ Detecting Probe for Radio-Guided Surgery in Tumour Resection
- 24 August 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 63 (5) , 2533-2539
Abstract
The development of the β - based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. To validate the technique, prototypes of the intraoperative β - probe have been developed. This paper discusses the design details of one of the prototypes and its tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The tests showed that the prototype under study has 70% efficiency on electrons with an energy threshold at 540 keV, a point-like resolution of 2.8±0.1 mm, and a sensitivity to photons lower than 1%. The tests also demonstrated, with an innovative technique to produce specific phantoms, that 0.5 ml residuals can be safely identified in 1 s with tumor-non-tumor ratio equal to 10.Keywords
All Related Versions
This publication has 13 references indexed in Scilit:
- Time Evolution of DOTATOC Uptake in Neuroendocrine Tumors in View of a Possible Application of Radioguided Surgery with β− DecayJournal of Nuclear Medicine, 2015
- Toward Radioguided Surgery with β− Decays: Uptake of a Somatostatin Analogue, DOTATOC, in Meningioma and High-Grade GliomaJournal of Nuclear Medicine, 2014
- The ArduSiPM a compact trasportable Software/Hardware Data Acquisition system for SiPM detector2014
- Properties of para-Terphenyl as a Detector for $\alpha $, $\beta $ and $\gamma $ RadiationIEEE Transactions on Nuclear Science, 2014
- A novel radioguided surgery technique exploiting β− decaysScientific Reports, 2014
- Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applicationsPhysica Medica, 2013
- A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imagingPhysics in Medicine & Biology, 2012
- Clinical results of radionuclide therapy of neuroendocrine tumours with 90Y-DOTATATE and tandem 90Y/177Lu-DOTATATE: which is a better therapy option?European Journal of Nuclear Medicine and Molecular Imaging, 2011
- A comprehensive overview of radioguided surgery using gamma detection probe technologyWorld Journal of Surgical Oncology, 2009
- Intraoperative beta probe: A device for detecting tissue labeled with positron or electron emitting isotopes during surgeryMedical Physics, 1994