A DC-connectable multi-channel biomedical data acquisition ASIC with mains frequency cancellation
- 1 September 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19308833,p. 149-152
Abstract
This paper presents an 8-channel biomedical data acquisition ASIC achieving 108dB of dynamic range (DR). Each channel includes a 13bit DAC to compensate differential input offset of up to ±300mV, preventing saturation of the high-gain instrumentation amplifier. Chopper stabilization and DAC-noise low-pass filtering lead to an input-referred noise of 0.8μV RMS . Data processing algorithms, implemented on an FPGA, are employed to remove artefacts due to sudden DAC-switching and to cancel 50/60Hz mains interference including its harmonics. The chip is fabricated in 130nm CMOS, occupying an active area of 2.2mm 2 and consuming 15mW from 1.2V and 3.3V supplies.Keywords
This publication has 4 references indexed in Scilit:
- A 0.013 ${\hbox {mm}}^{2}$, 5 $\mu\hbox{W}$, DC-Coupled Neural Signal Acquisition IC With 0.5 V SupplyIEEE Journal of Solid-State Circuits, 2011
- A Biomedical Sensor Interface With a sinc Filter and Interference CancellationIEEE Journal of Solid-State Circuits, 2011
- A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG SystemsIEEE Journal of Solid-State Circuits, 2008
- Powerline interference suppression in high-resolution ECG2003