Computer‐aided detection of clustered microcalcifications in multiscale bilateral filtering regularized reconstructed digital breast tomosynthesis volume
- 10 January 2014
- journal article
- radiation imaging-physics
- Published by Wiley in Medical Physics
- Vol. 41 (2) , 021901
Abstract
Purpose:: Develop a computer‐aided detection (CADe) system for clustered microcalcifications in digital breast tomosynthesis (DBT) volume enhanced with multiscale bilateral filtering (MSBF) regularization.Methods:: With Institutional Review Board approval and written informed consent, two‐view DBT of 154 breasts, of which 116 had biopsy‐proven microcalcification (MC) clusters and 38 were free of MCs, was imaged with a General Electric GEN2 prototype DBT system. The DBT volumes were reconstructed with MSBF‐regularized simultaneous algebraic reconstruction technique (SART) that was designed to enhance MCs and reduce background noise while preserving the quality of other tissue structures. The contrast‐to‐noise ratio (CNR) of MCs was further improved with enhancement‐modulated calcification response (EMCR) preprocessing, which combined multiscale Hessian response to enhance MCs by shape and bandpass filtering to remove the low‐frequency structured background. MC candidates were then located in the EMCR volume using iterative thresholding and segmented by adaptive region growing. Two sets of potential MC objects, cluster centroid objects and MC seed objects, were generated and the CNR of each object was calculated. The number of candidates in each set was controlled based on the breast volume. Dynamic clustering around the centroid objects grouped the MC candidates to form clusters. Adaptive criteria were designed to reduce false positive (FP) clusters based on the size, CNR values and the number of MCs in the cluster, cluster shape, and cluster based maximum intensity projection. Free‐response receiver operating characteristic (FROC) and jackknife alternative FROC (JAFROC) analyses were used to assess the performance and compare with that of a previous study.Results:: Unpaired two‐tailedt‐test showed a significant increase (p < 0.0001) in the ratio of CNRs for MCs with and without MSBF regularization compared to similar ratios for FPs. For view‐based detection, a sensitivity of 85% was achieved at an FP rate of 2.16 per DBT volume. For case‐based detection, a sensitivity of 85% was achieved at an FP rate of 0.85 per DBT volume. JAFROC analysis showed a significant improvement in the performance of the current CADe system compared to that of our previous system (p = 0.003).Conclusions:: MBSF regularized SART reconstruction enhances MCs. The enhancement in the signals, in combination with properly designed adaptive threshold criteria, effective MC feature analysis, and false positive reduction techniques, leads to a significant improvement in the detection of clustered MCs in DBT.Keywords
Funding Information
- U.S. Public Health Service (RO1 CA151443)
- U.S. Public Health Service (RO1 CA151443)
- Biomedical Research Partnership (CA91713)
This publication has 28 references indexed in Scilit:
- Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracyBritish Journal of Radiology, 2012
- Digital breast tomosynthesis (DBT): initial experience in a clinical settingActa Radiologica, 2012
- High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x‐ray source arrayMedical Physics, 2012
- Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: A 3D approachMedical Physics, 2011
- Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributionsMedical Physics, 2011
- Calcifications in the Breast and Digital Breast TomosynthesisThe Breast Journal, 2011
- Variability in Interpretive Performance at Screening Mammography and Radiologists’ Characteristics Associated with AccuracyRadiology, 2009
- Validation and Statistical Power Comparison of Methods for Analyzing Free-response Observer Performance StudiesAcademic Radiology, 2008
- Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: A preliminary studyMedical Physics, 2008
- The Laplacian Pyramid as a Compact Image CodeIEEE Transactions on Communications, 1983