Quantitative PET Imaging Using a Comprehensive Monte Carlo System Model
- 29 July 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2286-2295
Abstract
We present the complete image generation methodology developed for the RatCAP PET scanner, which can be extended to other PET systems for which a Monte Carlo-based system model is feasible. The miniature RatCAP presents a unique set of advantages as well as challenges for image processing, and a combination of conventional methods and novel ideas developed specifically for this tomograph have been implemented. The crux of our approach is a low-noise Monte Carlo-generated probability matrix with integrated corrections for all physical effects that impact PET image quality. The generation and optimization of this matrix are discussed in detail, along with the estimation of correction factors and their incorporation into the reconstruction framework. Phantom studies and Monte Carlo simulations are used to evaluate the reconstruction as well as individual corrections for random coincidences, photon scatter, attenuation, and detector efficiency variations in terms of bias and noise. Finally, a realistic rat brain phantom study reconstructed using this methodology is shown to recover >; 90% of the contrast for hot as well as cold regions. The goal has been to realize the potential of quantitative neuroreceptor imaging with the RatCAP.Keywords
This publication has 57 references indexed in Scilit:
- Simultaneous assessment of rodent behavior and neurochemistry using a miniature positron emission tomographNature Methods, 2011
- FIRST: Fast Iterative Reconstruction Software for (PET) tomographyPhysics in Medicine & Biology, 2006
- Rat‐PET study without anesthesia: Anesthetics modify the dopamine D1 receptor binding in rat brainSynapse, 2004
- A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolutionIEEE Transactions on Medical Imaging, 2003
- Statistically regulated and adaptive EM reconstruction for emission computed tomographyIEEE Transactions on Nuclear Science, 2001
- The potential of high-resolution positron emission tomography to monitor striatal dopaminergic function in rat models of disease.Journal of Neuroscience Methods, 1996
- Model-based scatter correction for fully 3D PETPhysics in Medicine & Biology, 1996
- Triple energy window scatter correction technique in PETIEEE Transactions on Medical Imaging, 1994
- Parallelization of the EM algorithm for 3-D PET image reconstructionIEEE Transactions on Medical Imaging, 1991
- PET system calibrations and corrections for quantitative and spatially accurate imagesIEEE Transactions on Nuclear Science, 1989