Abstract
Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the Σ − Δ noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 ppm Hz − 1 / 2 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the Σ − Δ actuation improves AC amplitude stability from 8 ppm Hz − 1 / 2 in the open loop design to 1 ppm Hz − 1 / 2 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.
Funding Information
  • National Natural Science Foundation of China (Grant No. 41874217)
  • National Key Research and Development Program of China (Project No.2020YFC2200800)

This publication has 22 references indexed in Scilit: