HFHongyi Fu

Hongyi Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongyi Fu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Ming Hu

    Huazhong University of Science and Technology

    3 shared publications
  • Zebing Zhou

    Huazhong University of Science and Technology

    3 shared publications
  • Chaoli Ouyang

    National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China

    2 shared publications
  • Jinfeng Lu

    National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China

    2 shared publications
  • Junjie Zhou

    National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and technology, Wuhan 430074, People’s Republic of China

    2 shared publications
  • Yanzheng Bai

    Huazhong University of Science and Technology

    2 shared publications

Latest Publications

  • Enhancing stray voltage measurement accuracy via continuous in-orbit compensation for inertial sensors

    by Jiayuan Geng, Junjie Zhou, Ming Hu, Hongyi Fu, Jingfeng Lu, Chaoli Ouyang, Yanzheng Bai, Zebing Zhou

  • Investigation of capacitive sensing crosstalk caused by field coupling through differential transformer in space gravitational reference sensors

    by Wendong Yu, Yanzheng Bai, Hongyi Fu, Ming Hu, Cheng Ma, Shaobo Qu, Chengrui Wang, Zebing Zhou

    The differential transformer is the core component of the capacitive displacement sensing system in high-precision gravitational reference sensors (GRS) used for space gravitational wave detection. However, sensing crosstalk between the different degrees of freedom within a compact space will be caused by the transformers. In this paper, a crosstalk model based on magnetic multipole expansion for capacitive sensing caused by transformer field coupling is proposed and established. A physics-based simulation method is established to evaluate transformer coupling effects, revealing that the coupling coefficient is related to radial higher-order terms and angle between transformers. Experimental and simulation results indicate that the selected transformer coupling coefficient is at the order of 10 −4 when the transformer axes are aligned and the spacing is approximately 28 mm. Based on the crosstalk model, the coupling contribution of the GRS acceleration noise from non-sensitive direction to sensitive direction introduced by capacitive sensing is less than 1.3 × 10 −19 m s −2 Hz −1/2 . These results provide theoretical guidance for the transformer layout in future integrated electronic engineering systems.

  • Improving actuation stability with sigma-delta noise shaping technique for space gravitational reference system

    by Jinfeng Lu, Yiyan Jiang, Junjie Zhou, Ming Hu, Xiaotian Yang, Duo Li, Chaoli Ouyang, Hongyi Fu, Chujie Zhang, Yanzheng Bai, et al.

    Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the Σ − Δ noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 ppm Hz − 1 / 2 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the Σ − Δ actuation improves AC amplitude stability from 8 ppm Hz − 1 / 2 in the open loop design to 1 ppm Hz − 1 / 2 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.