Mitigation of Grid-Current Distortion for LCL-Filtered Voltage-Source Inverter With Inverter-Current Feedback Control
- 17 August 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (7) , 6248-6261
Abstract
LCL filters feature low inductance; thus, the injected grid current from an LCL -filtered voltage-source inverter can be easily distorted by grid-voltage harmonics. This problem is especially tough for the control system with inverter-side current feedback (ICF), since the grid-current harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid-current distortion. Although this problem may be avoided using the grid-voltage feedforward scheme, the required differentiators may cause the noise amplification. In light of the above issue, this paper develops a simple method for the ICF control system to mitigate the grid-current harmonics without extra sensors. In the proposed method, resonant harmonic controllers and an additional compensation loop are adopted at the same time. The potential instability introduced by the compensation loop can be avoided through a special design of the compensation position. Finally, the effectiveness of the proposed method for harmonic rejection is verified by detailed experimental results.Keywords
Funding Information
- European Research Council (321149-Harmony)
This publication has 25 references indexed in Scilit:
- Improved Power Decoupling Scheme for a Single-Phase Grid-Connected Differential Inverter With Realistic Mismatch in Storage CapacitancesIEEE Transactions on Power Electronics, 2016
- Design of LCL Filters With LCL Resonance Frequencies Beyond the Nyquist Frequency for Grid-Connected ConvertersIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- Realization of Digital Differentiator Using Generalized Integrator For Power ConvertersIEEE Transactions on Power Electronics, 2015
- New Metric Recommended for IEEE Standard 1547 to Limit Harmonics Injected Into Distorted GridsIEEE Transactions on Power Delivery, 2015
- Delay-Dependent Stability of Single-Loop Controlled Grid-Connected Inverters with LCL FiltersIEEE Transactions on Power Electronics, 2015
- Inverter-side current control of a single-phase inverter grid connected trough an LCL filter2014
- Extended Application of D-${\bf Σ}$ Digital Control to a Single-Phase Bidirectional Inverter With an LCL FilterIEEE Transactions on Power Electronics, 2014
- Optimized Controller Design for $LCL$-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance VariationIEEE Transactions on Industrial Electronics, 2014
- Admittance Compensation in Current Loop Control for a Grid-Tie LCL Fuel Cell InverterIEEE Transactions on Power Electronics, 2008
- Suppression of Line Voltage Related Distortion in Current Controlled Grid Connected InvertersIEEE Transactions on Power Electronics, 2005