Optimized Controller Design for $LCL$-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance Variation
Authors:
- 22 July 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 62 (3) , 1537-1547
Abstract
Capacitor-current-feedback active damping is an effective method to suppress the LCL-filter resonance in grid-connected inverters. However, due to the variation of grid impedance, the LCL-filter resonance frequency will vary in a wide range, which challenges the design of the capacitor-current-feedback coefficient. Moreover, if the resonance frequency is equal to one-sixth of the sampling frequency (f s /6), the digitally controlled LCL-type grid-connected inverter can be hardly stable no matter how much the capacitor-current-feedback coefficient is. In this paper, the optimal design of the capacitor-current-feedback coefficient is presented to deal with the wide-range variation of grid impedance. First, the gain margin requirements for system stability are derived under various resonance frequencies. By evaluating the effect of grid impedance on gain margins, an optimal capacitor-current-feedback coefficient is obtained. With this feedback coefficient, stable operations will be retained for all resonance frequencies except (f s /6). Second, in order to improve system stability for a resonance frequency of (f s /6), a phase-lag compensation for the loop gain is proposed. Finally, a 6-kW prototype is tested to verify the proposed design procedure.Keywords
Funding Information
- National Natural Science Foundation of China (50837003, 51007027)
- Jiangsu Province 333 Program for Excellent Talents (BRA2012141)
- Fundamental Research Funds for the Central Universities (YAH12012)
This publication has 24 references indexed in Scilit:
- Two Degrees of Freedom Active Damping Technique for $LCL$ Filter-Based Grid Connected PV SystemsIEEE Transactions on Industrial Electronics, 2013
- Regions of Active Damping Control for LCL FiltersIEEE Transactions on Industry Applications, 2013
- Direct Grid Current Control of LCL-Filtered Grid-Connected Inverter Mitigating Grid Voltage DisturbanceIEEE Transactions on Power Electronics, 2013
- Full-Feedforward Schemes of Grid Voltages for a Three-Phase $LCL$-Type Grid-Connected InverterIEEE Transactions on Industrial Electronics, 2012
- Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With $LCL$ filtersIEEE Transactions on Industrial Electronics, 2012
- Generalized Design of High Performance Shunt Active Power Filter With Output LCL FilterIEEE Transactions on Industrial Electronics, 2011
- Active Damping of Output $LC$ Filter Resonance for Vector-Controlled VSI-Fed AC Motor DrivesIEEE Transactions on Industrial Electronics, 2011
- Effects of Discretization Methods on the Performance of Resonant ControllersIEEE Transactions on Power Electronics, 2010
- Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL FilterIEEE Transactions on Power Electronics, 2009
- Overview of Control and Grid Synchronization for Distributed Power Generation SystemsIEEE Transactions on Industrial Electronics, 2006