Optimization of iterative reconstruction parameters with 3-dimensional resolution recovery, scatter and attenuation correction in 123I-FP-CIT SPECT
- 22 May 2015
- journal article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 29 (7) , 636-642
Abstract
The aim of this study was to determine the optimal reconstruction parameters on ordered-subset expectation maximization iterative reconstruction with resolution recovery, scatter and attenuation correction (OSEMRRSCAC) on 123I-FP-CIT SPECT in terms of the image quality, quantification and diagnostic ability. We evaluated the quality and quantification in 123I-FP-CIT SPECT images obtained by different reconstruction parameters using the anthropomorphic striatal phantom. The phantom images were acquired using a SPECT/CT system equipped with a low- and medium-energy general-purpose collimator and then were reconstructed using OSEMRRSCAC with various update numbers and the full width at half maximum (FWHM) of the Gaussian filter. The count ratio of the striatum, the coefficient of variation (CV) on the background and the specific binding ratio (SBR) were calculated to determine the optimal reconstruction parameters. Then, 42 consecutive patients who underwent 123I-FP-CIT SPECT were selected for clinical study. The patients were grouped into potentially decreasing group (20 with Parkinson’s disease, 5 with parkinsonian syndrome and 5 with dementia with Lewy bodies) and potentially normal binding group (4 with Alzheimer disease and 8 with essential tremor). Clinical images were reconstructed using OSEMRRSCAC and FBP with Chang’s AC (FBPAC). The performance of OSEMRRSCAC with the optimal reconstruction parameters was evaluated according to the receiver operating characteristic analysis and visual assessment. The count ratio increased with an increasing update number and converged uniformly with an update number over 90. The CV continuously increased with the update number. The SBR also increased with an increasing update number and converged uniformly with an update number of 90 or larger. The FWHM of the Gaussian filter influenced the image quality and quantification. In the clinical study, the area under curve (AUC) for the OSEMRRSCAC and FBPAC were 0.9812 and 0.9759, respectively. The quality of the SPECT images of OSEMRRSCAC (3.8 ± 0.8) was significantly superior to that of FBPAC (2.2 ± 0.7). We determined that the optimal reconstruction parameter for OSEMRRSCAC was 90 update numbers with 6.6 mm FWHM of the Gaussian filter. Our results suggested that the optimal reconstruction parameters have a potential to improve the performance and the image quality of 123I-FP-CIT SPECT in comparison with the FBP reconstruction.Keywords
This publication has 15 references indexed in Scilit:
- Comparison between visual assessment of dopaminergic degeneration pattern and semi-quantitative ratio calculations in patients with Parkinson’s disease and Atypical Parkinsonian syndromes using DaTSCAN® SPECTAnnals of Nuclear Medicine, 2014
- Image Quality and Data Quantification in Dopamine Transporter SPECTClinical Nuclear Medicine, 2012
- SNM Practice Guideline for Dopamine Transporter Imaging with 123I-Ioflupane SPECT 1.0Journal of Nuclear Medicine, 2011
- EANM procedure guidelines for brain neurotransmission SPECT using 123I-labelled dopamine transporter ligands, version 2European Journal of Nuclear Medicine and Molecular Imaging, 2009
- The impact of reconstruction method on the quantification of DaTSCAN imagesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- Quantification of [123I]FP-CIT SPECT brain images: an accurate technique for measurement of the specific binding ratioEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Iterative reconstruction with correction of the spatially variant fan-beam collimator response in neurotransmission SPET imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: The [123I]-FP-CIT study groupMovement Disorders, 2000
- Striatal Dopamine Transporter Binding Assessed by [I-123]IPT and Single Photon Emission Computed Tomography in Patients With Early Parkinson's DiseaseArchives of Neurology, 2000
- [123I]FP-CIT SPECT shows a pronounced decline of striatal dopamine transporter labelling in early and advanced Parkinson's disease.Journal of Neurology, Neurosurgery & Psychiatry, 1997