Masayuki Sasaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masayuki Sasaki has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Go Akamatsu
National Institutes for Quantum Science and Technology
12 shared publications Shingo Baba
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Higashi-ku
12 shared publicationsKazuhiko Himuro
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan; and
9 shared publicationsAkira Maebatake
Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
7 shared publications- Shingo Baba
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
7 shared publications Yuji Tsutsui
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan; and
7 shared publications
Latest Publications
- 19 April 2021
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 35 (6) , 735-743
Influences of radionuclides on left ventricular phase analysis of gated myocardial perfusion single-photon emission computed tomography images in ischemic heart disease
Objective Phase analysis is expected to improve the accuracy of myocardial ischemia diagnosis in conjunction with myocardial perfusion and wall motion imaging and quantification. Although previous studies have reported perfusion image disagreements in relation to radionuclides, a few reports have examined the influences of radionuclides on phase analysis. We evaluated the influences of different radionuclides on stress-induced left ventricular mechanical dyssynchrony by phase analysis using electrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) (MPS) imaging in patients with ischemic heart disease (IHD). Methods A total of 202 patients with suspected or known IHD were investigated retrospectively. All the patients underwent coronary arteriography and were subsequently classified into the following groups: 43 patients without any coronary lesion (0VD), 71 patients with single-vessel disease (1VD), 59 patients with two-vessel disease (2VD), and 29 patients with three-vessel disease (3VD). Both stress and rest gated-MPS were performed using 99mTc-methoxyisobutylisonitrile (MIBI)/tetrofosmin (TF) in 118 patients and with 201TlCl in 84 patients. Phase analysis was performed to obtain the peak phase, phase standard deviation (SD), and bandwidth. Finally, we investigated potential differences between the phase analysis indices and the respective radionuclides used. Results The peak phase did not exhibit any significant differences in the numbers of affected branches in either 99mTc-MPS or 201Tl-MPS during stress or rest MPS. Furthermore, both the phase SD and bandwidth demonstrated a tendency to increase in patients with increased numbers of affected branches. A significant difference was observed in the stress MPS when 99mTc-MIBI/TF was used (p < 0.05), but no significant difference was observed in the stress MPS when 201TlCl was used. Both the phase SD and bandwidth of all patients in 99mTc-MPS during stress were significantly larger than those at rest (p < 0.05). Conversely, both the phase SD and bandwidth of all patients in 201Tl-MPS at stress was significantly smaller than that at rest (p < 0.05). Conclusion Phase analysis using 99mTc-MPS was considered to be useful for the detection of stress-induced left ventricular mechanical dyssynchrony, although it is necessary to be careful when using 201Tl-MPS.
- 19 April 2021
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 35 (6) , 735-743
Influences of radionuclides on left ventricular phase analysis of gated myocardial perfusion single-photon emission computed tomography images in ischemic heart disease
Objective Phase analysis is expected to improve the accuracy of myocardial ischemia diagnosis in conjunction with myocardial perfusion and wall motion imaging and quantification. Although previous studies have reported perfusion image disagreements in relation to radionuclides, a few reports have examined the influences of radionuclides on phase analysis. We evaluated the influences of different radionuclides on stress-induced left ventricular mechanical dyssynchrony by phase analysis using electrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) (MPS) imaging in patients with ischemic heart disease (IHD). Methods A total of 202 patients with suspected or known IHD were investigated retrospectively. All the patients underwent coronary arteriography and were subsequently classified into the following groups: 43 patients without any coronary lesion (0VD), 71 patients with single-vessel disease (1VD), 59 patients with two-vessel disease (2VD), and 29 patients with three-vessel disease (3VD). Both stress and rest gated-MPS were performed using 99mTc-methoxyisobutylisonitrile (MIBI)/tetrofosmin (TF) in 118 patients and with 201TlCl in 84 patients. Phase analysis was performed to obtain the peak phase, phase standard deviation (SD), and bandwidth. Finally, we investigated potential differences between the phase analysis indices and the respective radionuclides used. Results The peak phase did not exhibit any significant differences in the numbers of affected branches in either 99mTc-MPS or 201Tl-MPS during stress or rest MPS. Furthermore, both the phase SD and bandwidth demonstrated a tendency to increase in patients with increased numbers of affected branches. A significant difference was observed in the stress MPS when 99mTc-MIBI/TF was used (p < 0.05), but no significant difference was observed in the stress MPS when 201TlCl was used. Both the phase SD and bandwidth of all patients in 99mTc-MPS during stress were significantly larger than those at rest (p < 0.05). Conversely, both the phase SD and bandwidth of all patients in 201Tl-MPS at stress was significantly smaller than that at rest (p < 0.05). Conclusion Phase analysis using 99mTc-MPS was considered to be useful for the detection of stress-induced left ventricular mechanical dyssynchrony, although it is necessary to be careful when using 201Tl-MPS.
- 5 April 2021
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 49 (3) , 256-261
Improved Accuracy of Amyloid PET Quantification with Adaptive Template–Based Anatomic Standardization
Amyloid positron emission tomography (PET) noninvasively visualizes amyloid-β (Aβ) accumulation in the brain. Visual binary reading is the standard method for interpreting amyloid PET, while objective quantitative evaluation is required in research and clinical trials. Anatomical standardization is important for quantitative analysis, and various standard templates are used for this purpose. To address the large differences in the radioactivity distribution between amyloid-positive and amyloid-negative participants, an adaptive template method has been proposed for the anatomical standardization of amyloid PET. In this study, we investigated the difference between the adaptive template method and the single template methods (use of a positive or a negative template) in amyloid PET quantitative evaluation, focusing on the accuracy in diagnosing Alzheimer’s disease (AD). Methods: A total of 166 participants (58 normal controls (NCs), 62 participants with mild cognitive impairment (MCI), and 46 patients with AD) who underwent [11C] Pittsburgh Compound B PET (11C-PiB) through the Japanese Alzheimer's Disease Neuroimaging Initiative study were examined. For the anatomical standardization of 11C-PiB PET images, we applied three methods a positive template-based method, a negative template-based method, and adaptive template-based method. The positive template was created by averaged four patients with AD and seven patients with MCI PET images. Conversely, the negative template was created by averaged eight participants of NC PET images. In the adaptive template-based method, either of the templates was used on the basis of the similarity (normalized cross-correlation (NCC)) between the individual standardized image and the corresponding template. Empirical PiB-prone region-of-interest was used to evaluate specific regions where Aβ accumulates. The reference region was the cerebellar cortex, whereas the evaluated regions were the posterior cingulate gyrus and precuneus as well as the frontal, lateral temporal, lateral parietal, and occipital lobes. The mean cortical standardized uptake value ratio (mcSUVR) was calculated for quantitative evaluation. Results: The NCCs of single template-based methods (the positive template or negative template) showed a significant difference between NC, MCI and AD (P < 0.05), whereas the NCC of the adaptive template-based method did not (P > 0.05). The mcSUVR exhibited significant differences between NC, MCI and AD in all methods (P < 0.05). The area under curve by receiver operating characteristic analysis between the positive group (MCI and AD) and NC was not significantly different in mcSUVR among all templates. With regard to diagnostic accuracy based on mcSUVR, the sensitivity of the negative and adaptive template-based methods was superior to that of the positive template-based method (P < 0.05); however, there was no significant difference in specificity between them. Conclusion: In the diagnostic accuracy for AD by amyloid PET quantitative evaluation, the adaptive template-based anatomical standardization method outperformed the single template-based methods.
- 5 April 2021
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 49 (3) , 256-261
Improved Accuracy of Amyloid PET Quantification with Adaptive Template–Based Anatomic Standardization
Amyloid positron emission tomography (PET) noninvasively visualizes amyloid-β (Aβ) accumulation in the brain. Visual binary reading is the standard method for interpreting amyloid PET, while objective quantitative evaluation is required in research and clinical trials. Anatomical standardization is important for quantitative analysis, and various standard templates are used for this purpose. To address the large differences in the radioactivity distribution between amyloid-positive and amyloid-negative participants, an adaptive template method has been proposed for the anatomical standardization of amyloid PET. In this study, we investigated the difference between the adaptive template method and the single template methods (use of a positive or a negative template) in amyloid PET quantitative evaluation, focusing on the accuracy in diagnosing Alzheimer’s disease (AD). Methods: A total of 166 participants (58 normal controls (NCs), 62 participants with mild cognitive impairment (MCI), and 46 patients with AD) who underwent [11C] Pittsburgh Compound B PET (11C-PiB) through the Japanese Alzheimer's Disease Neuroimaging Initiative study were examined. For the anatomical standardization of 11C-PiB PET images, we applied three methods a positive template-based method, a negative template-based method, and adaptive template-based method. The positive template was created by averaged four patients with AD and seven patients with MCI PET images. Conversely, the negative template was created by averaged eight participants of NC PET images. In the adaptive template-based method, either of the templates was used on the basis of the similarity (normalized cross-correlation (NCC)) between the individual standardized image and the corresponding template. Empirical PiB-prone region-of-interest was used to evaluate specific regions where Aβ accumulates. The reference region was the cerebellar cortex, whereas the evaluated regions were the posterior cingulate gyrus and precuneus as well as the frontal, lateral temporal, lateral parietal, and occipital lobes. The mean cortical standardized uptake value ratio (mcSUVR) was calculated for quantitative evaluation. Results: The NCCs of single template-based methods (the positive template or negative template) showed a significant difference between NC, MCI and AD (P < 0.05), whereas the NCC of the adaptive template-based method did not (P > 0.05). The mcSUVR exhibited significant differences between NC, MCI and AD in all methods (P < 0.05). The area under curve by receiver operating characteristic analysis between the positive group (MCI and AD) and NC was not significantly different in mcSUVR among all templates. With regard to diagnostic accuracy based on mcSUVR, the sensitivity of the negative and adaptive template-based methods was superior to that of the positive template-based method (P < 0.05); however, there was no significant difference in specificity between them. Conclusion: In the diagnostic accuracy for AD by amyloid PET quantitative evaluation, the adaptive template-based anatomical standardization method outperformed the single template-based methods.
- 1 April 2021
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 39 (4) , 387-394
Evaluation of a Monte Carlo-based algorithm for the influence of totally implantable venous access ports in external radiation therapy
Purpose This study aimed to assess whether a Monte Carlo (MC)-based algorithm reflects the influence of totally implantable venous access ports (TIVAPs) in external radiation therapy. Materials and Methods The present study comprised two steps: experimental measurements of depth doses and surface doses with and without TIVAPs and calculation with an MC-based algorithm. Results The TIVAP-associated maximum dose reduction compared with the dose at the same depths without TIVAPs was 7.8% at 4 MV, 6.9% at 6 MV, and 5.7% at 10 MV in measurement, and 7.4% at 4 MV, 6.6% at 6 MV, and 5.5% at 10 MV in calculation. Relative surface doses were higher with TIVAPs made of titanium, due to a higher fluence of backscattered electrons from the TIVAPs, than with plastic TIVAPs. There were no significant differences in the relative differences between the measured and calculated doses of the titanium TIVAP group and the plastic TIVAP group at 4 MV (p = 0.99), 6 MV (p = 0.67), and 10 MV (p = 0.54). Conclusion TIVAPs caused target dose reductions and dose increase near the TIVAP, especially when made of titanium. The influences are reflected in the MC-based algorithm.
- 1 April 2021
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 39 (4) , 387-394
Evaluation of a Monte Carlo-based algorithm for the influence of totally implantable venous access ports in external radiation therapy
Purpose This study aimed to assess whether a Monte Carlo (MC)-based algorithm reflects the influence of totally implantable venous access ports (TIVAPs) in external radiation therapy. Materials and Methods The present study comprised two steps: experimental measurements of depth doses and surface doses with and without TIVAPs and calculation with an MC-based algorithm. Results The TIVAP-associated maximum dose reduction compared with the dose at the same depths without TIVAPs was 7.8% at 4 MV, 6.9% at 6 MV, and 5.7% at 10 MV in measurement, and 7.4% at 4 MV, 6.6% at 6 MV, and 5.5% at 10 MV in calculation. Relative surface doses were higher with TIVAPs made of titanium, due to a higher fluence of backscattered electrons from the TIVAPs, than with plastic TIVAPs. There were no significant differences in the relative differences between the measured and calculated doses of the titanium TIVAP group and the plastic TIVAP group at 4 MV (p = 0.99), 6 MV (p = 0.67), and 10 MV (p = 0.54). Conclusion TIVAPs caused target dose reductions and dose increase near the TIVAP, especially when made of titanium. The influences are reflected in the MC-based algorithm.
- Open Access
- 29 September 2020
- Published by Springer Nature in EJNMMI Physics
- Vol. 7 (1) , 1-12
Development and evaluation of an automated quantification tool for amyloid PET images
Background: Quantitative evaluation of amyloid positron emission tomography (PET) with standardized uptake value ratio (SUVR) plays a key role in clinical studies of Alzheimer’s disease (AD). We have proposed a PET-only (MR-free) amyloid quantification method, although some commercial software packages are required. The aim of this study was to develop an automated quantification tool for amyloid PET without using commercial software. Methods: The quantification tool was created by combining four components: (1) anatomical standardization to positive and negative templates using NEUROSTAT stereo.exe; (2) similarity calculation between standardized images and respective templates based on normalized cross-correlation (selection of the image for SUVR measurement); (3) voxel value normalization by the mean value of reference regions (making an SUVR-scaled image); and (4) SUVR calculation based on pre-defined regions of interest (ROIs). We examined 166 subjects who underwent a [11C] Pittsburgh compound-B PET scan through the Japanese Alzheimer’s Disease Neuroimaging Initiative (J-ADNI) study. SUVRs in five ROIs (frontal lobe, temporal lobe, parietal lobe, occipital lobe, and posterior cingulate cortex and precuneus) were calculated with the cerebellar cortex as the reference region. The SUVRs obtained by our tool were compared with manual step-by-step processing and the conventional PMOD-based method (PMOD Technologies, Switzerland). Results: Compared with manual step-by-step processing, our developed automated quantification tool reduced processing time by 85%. The SUVRs obtained by the developed quantification tool were consistent with those obtained by manual processing. Compared with the conventional PMOD-based method, the developed quantification tool provided 1.5% lower SUVR values, on average. We determined that this bias is likely due to the difference in anatomical standardization methods. Conclusions: We developed an automated quantification tool for amyloid PET images. Using this tool, SUVR values can be quickly measured without individual MRI and without commercial software. This quantification tool may be useful for clinical studies of AD.
- 29 September 2020
- Published by Springer Nature in EJNMMI Physics
- Vol. 7 (1) , 1-12
Open AccessDevelopment and evaluation of an automated quantification tool for amyloid PET images
Background: Quantitative evaluation of amyloid positron emission tomography (PET) with standardized uptake value ratio (SUVR) plays a key role in clinical studies of Alzheimer’s disease (AD). We have proposed a PET-only (MR-free) amyloid quantification method, although some commercial software packages are required. The aim of this study was to develop an automated quantification tool for amyloid PET without using commercial software. Methods: The quantification tool was created by combining four components: (1) anatomical standardization to positive and negative templates using NEUROSTAT stereo.exe; (2) similarity calculation between standardized images and respective templates based on normalized cross-correlation (selection of the image for SUVR measurement); (3) voxel value normalization by the mean value of reference regions (making an SUVR-scaled image); and (4) SUVR calculation based on pre-defined regions of interest (ROIs). We examined 166 subjects who underwent a [11C] Pittsburgh compound-B PET scan through the Japanese Alzheimer’s Disease Neuroimaging Initiative (J-ADNI) study. SUVRs in five ROIs (frontal lobe, temporal lobe, parietal lobe, occipital lobe, and posterior cingulate cortex and precuneus) were calculated with the cerebellar cortex as the reference region. The SUVRs obtained by our tool were compared with manual step-by-step processing and the conventional PMOD-based method (PMOD Technologies, Switzerland). Results: Compared with manual step-by-step processing, our developed automated quantification tool reduced processing time by 85%. The SUVRs obtained by the developed quantification tool were consistent with those obtained by manual processing. Compared with the conventional PMOD-based method, the developed quantification tool provided 1.5% lower SUVR values, on average. We determined that this bias is likely due to the difference in anatomical standardization methods. Conclusions: We developed an automated quantification tool for amyloid PET images. Using this tool, SUVR values can be quickly measured without individual MRI and without commercial software. This quantification tool may be useful for clinical studies of AD.
- 13 June 2020
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (9) , 629-635
Feasibility study of a PET-only amyloid quantification method: a comparison with visual interpretation
Objective Visual evaluation is the standard for amyloid positron emission tomography (PET) examination, though the result depends upon the physician’s subjective review of the images. Therefore, it is expected that objective quantitative evaluation is useful for image interpretation. In this study, we examined the usefulness of the quantitative evaluation of amyloid PET using a PET-only quantification method in comparison with visual evaluation. Methods In this study we retrospectively investigated a total of 166 individuals, including 58 cognitively normal controls, 62 individuals with mild cognitive impairment, and 46 individuals with early Alzheimer’s disease. They underwent 11C-Pittsburgh compound-B (PiB) PET examination through the Japanese Alzheimer’s Disease Neuroimaging Initiative (J-ADNI). Amyloid accumulation in cerebral cortices was assessed using visual and quantitative methods. The quantitative evaluation was performed using the adaptive template method and empirically PiB-prone region of interest, and the standardized uptake value ratio (SUVR) in each area was obtained. Results Visual evaluation and SUVR were significantly correlated in the cerebral cortices (ρ = 0.85–0.87; p < 0.05). In visual evaluation, sensitivity, specificity, and accuracy were 78%, 76%, and 77%, respectively. Meanwhile, for quantitative evaluation, sensitivity, specificity, and accuracy were 77%, 79%, and 78% in mean cortical SUVR (mcSUVR) and 79%, 79%, and 79% in maximum SUVR (maxSUVR), respectively. Conclusion The PET-only quantification method provided a concordant result with visual evaluation and was considered useful for amyloid PET.
- 13 June 2020
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (9) , 629-635
Feasibility study of a PET-only amyloid quantification method: a comparison with visual interpretation
Objective Visual evaluation is the standard for amyloid positron emission tomography (PET) examination, though the result depends upon the physician’s subjective review of the images. Therefore, it is expected that objective quantitative evaluation is useful for image interpretation. In this study, we examined the usefulness of the quantitative evaluation of amyloid PET using a PET-only quantification method in comparison with visual evaluation. Methods In this study we retrospectively investigated a total of 166 individuals, including 58 cognitively normal controls, 62 individuals with mild cognitive impairment, and 46 individuals with early Alzheimer’s disease. They underwent 11C-Pittsburgh compound-B (PiB) PET examination through the Japanese Alzheimer’s Disease Neuroimaging Initiative (J-ADNI). Amyloid accumulation in cerebral cortices was assessed using visual and quantitative methods. The quantitative evaluation was performed using the adaptive template method and empirically PiB-prone region of interest, and the standardized uptake value ratio (SUVR) in each area was obtained. Results Visual evaluation and SUVR were significantly correlated in the cerebral cortices (ρ = 0.85–0.87; p < 0.05). In visual evaluation, sensitivity, specificity, and accuracy were 78%, 76%, and 77%, respectively. Meanwhile, for quantitative evaluation, sensitivity, specificity, and accuracy were 77%, 79%, and 78% in mean cortical SUVR (mcSUVR) and 79%, 79%, and 79% in maximum SUVR (maxSUVR), respectively. Conclusion The PET-only quantification method provided a concordant result with visual evaluation and was considered useful for amyloid PET.
- 11 June 2020
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (8) , 583-594
Accuracy of metabolic volume and total glycolysis among six threshold-based target segmentation algorithms
Objective This study aimed to evaluate the accuracy of six threshold-based segmentation methods with different target-to-background ratios (TBR), images with different voxel sizes and image noise, in measuring metabolic volume (MV) and total glycolysis (TG). Methods A standard body phantom consisting of six spheres (inner diameters of 37, 28, 22, 17, 13, and 10 mm) was filled with 18F-FDG solution. The background radioactivity level was 2.65 kBq/mL, and the TBRs were 4 and 8. PET data were acquired for 30 min with list mode. PET data for 30 and 3 min were reconstructed with a three-dimensional ordered subset expectation maximization algorithm plus time-of-flight information with images with 2 and 4 mm isotropic voxels. The six methods examined were absolute standardized uptake value (SUV) of 2.5 (SUV2.5), 41%, 50%, adaptive 41%, and adaptive 50% thresholds of maximum SUV (Th41, Th50, ThA41, and ThA50, respectively); and the contrast-oriented algorithm (ThCOA). Segmented MV and TG were compared with the actual inner volume and expressed as percentages (%MVseg and %TGseg, respectively). In addition, the segmented MV was converted to the diameter, and the differences of it from the reference diameter were compared among six methods. Results The ThCOA method yielded the most accurate measurements of %MVseg and %TGseg; the difference between %MVseg or %TGseg and its reference were smaller than 10% in 30-min and 15% in 3-min images, but the segmented contour was almost the same as the reference diameter. Measurements with Th50 and ThCOA were highly accurate for both %MVseg and %TGseg in the large spheres, and the adaptive threshold methods, including ThA41, ThA50, and ThCOA, were also highly accurate in the small spheres. The voxel sizes affected the accuracy of %MVseg and %TGseg with a TBR of 4 in any threshold-based methods. Conclusions Of the six threshold-based segmentation methods studied, ThCOA was the most accurate method for evaluating MV and TG and had only minor dependence on TBRs and sphere size. The small voxel sizes improved the variation of the accuracy in low TBR.
- 11 June 2020
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (8) , 583-594
Accuracy of metabolic volume and total glycolysis among six threshold-based target segmentation algorithms
Objective This study aimed to evaluate the accuracy of six threshold-based segmentation methods with different target-to-background ratios (TBR), images with different voxel sizes and image noise, in measuring metabolic volume (MV) and total glycolysis (TG). Methods A standard body phantom consisting of six spheres (inner diameters of 37, 28, 22, 17, 13, and 10 mm) was filled with 18F-FDG solution. The background radioactivity level was 2.65 kBq/mL, and the TBRs were 4 and 8. PET data were acquired for 30 min with list mode. PET data for 30 and 3 min were reconstructed with a three-dimensional ordered subset expectation maximization algorithm plus time-of-flight information with images with 2 and 4 mm isotropic voxels. The six methods examined were absolute standardized uptake value (SUV) of 2.5 (SUV2.5), 41%, 50%, adaptive 41%, and adaptive 50% thresholds of maximum SUV (Th41, Th50, ThA41, and ThA50, respectively); and the contrast-oriented algorithm (ThCOA). Segmented MV and TG were compared with the actual inner volume and expressed as percentages (%MVseg and %TGseg, respectively). In addition, the segmented MV was converted to the diameter, and the differences of it from the reference diameter were compared among six methods. Results The ThCOA method yielded the most accurate measurements of %MVseg and %TGseg; the difference between %MVseg or %TGseg and its reference were smaller than 10% in 30-min and 15% in 3-min images, but the segmented contour was almost the same as the reference diameter. Measurements with Th50 and ThCOA were highly accurate for both %MVseg and %TGseg in the large spheres, and the adaptive threshold methods, including ThA41, ThA50, and ThCOA, were also highly accurate in the small spheres. The voxel sizes affected the accuracy of %MVseg and %TGseg with a TBR of 4 in any threshold-based methods. Conclusions Of the six threshold-based segmentation methods studied, ThCOA was the most accurate method for evaluating MV and TG and had only minor dependence on TBRs and sphere size. The small voxel sizes improved the variation of the accuracy in low TBR.
- Open Access
- 18 February 2020
- Published by Springer Nature in Research Square
Feasibility study of amyloid PET-only quantification; a comparison with visual interpretation.
Objective Visual evaluation is the standard for amyloid positron emission tomography (PET) examination, though the result depends upon the physician’s subjective review of the images. Therefore, objective quantitative evaluation is expected to be useful for image interpretation. In this study, we examined the usefulness of the quantitative evaluation of amyloid PET using a PET-only quantification method in comparison with visual evaluation. Methods A total of 166 individuals, including 58 cognitively normal controls, 62 individuals with mild cognitive impairment, and 46 individuals with early Alzheimer’s disease, were retrospectively investigated. They underwent 11C-Pittsburgh compound-B (PiB) PET examination through the Japanese-Alzheimer’s disease neuroimaging initiative (J-ADNI). Amyloid accumulation in cerebral cortices was assessed using visual and quantitative methods. The quantitative evaluation was performed using the adaptive template method and empirically PiB-prone region of interest, and the standardized uptake value ratio (SUVR) in each area was obtained. Results Visual evaluation and SUVR were significantly correlated in the cerebral cortices (ρ = 0.85–0.87; p < 0.05). In visual evaluation, the sensitivity, specificity, and accuracy were 78%, 76%, and 77%, respectively. Meanwhile, for quantitative evaluation, the sensitivity, specificity, and accuracy were 78%, 76%, and 77%, in mean cortical SUVR (mcSUVR) and 79%, 79%, and 79% in maximum SUVR (maxSUVR), respectively. Conclusion The PET-only quantification method resulted in a concordant result with visual evaluation and was considered to be useful for amyloid PET.
- 18 February 2020
- Published by Springer Nature in Research Square
Open AccessFeasibility study of amyloid PET-only quantification; a comparison with visual interpretation.
Objective Visual evaluation is the standard for amyloid positron emission tomography (PET) examination, though the result depends upon the physician’s subjective review of the images. Therefore, objective quantitative evaluation is expected to be useful for image interpretation. In this study, we examined the usefulness of the quantitative evaluation of amyloid PET using a PET-only quantification method in comparison with visual evaluation. Methods A total of 166 individuals, including 58 cognitively normal controls, 62 individuals with mild cognitive impairment, and 46 individuals with early Alzheimer’s disease, were retrospectively investigated. They underwent 11C-Pittsburgh compound-B (PiB) PET examination through the Japanese-Alzheimer’s disease neuroimaging initiative (J-ADNI). Amyloid accumulation in cerebral cortices was assessed using visual and quantitative methods. The quantitative evaluation was performed using the adaptive template method and empirically PiB-prone region of interest, and the standardized uptake value ratio (SUVR) in each area was obtained. Results Visual evaluation and SUVR were significantly correlated in the cerebral cortices (ρ = 0.85–0.87; p < 0.05). In visual evaluation, the sensitivity, specificity, and accuracy were 78%, 76%, and 77%, respectively. Meanwhile, for quantitative evaluation, the sensitivity, specificity, and accuracy were 78%, 76%, and 77%, in mean cortical SUVR (mcSUVR) and 79%, 79%, and 79% in maximum SUVR (maxSUVR), respectively. Conclusion The PET-only quantification method resulted in a concordant result with visual evaluation and was considered to be useful for amyloid PET.
- 1 November 2019
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 40 (11) , 1166-1173
Differences in edge artifacts between 68Ga- and 18F-PET images reconstructed using point spread function correction
Objective: Edge artifacts have been reported on in relation to 18F-PET using point spread function correction algorithms. The positron range of 68Ga is longer than 18F, and this difference is thought to result in different edge artifacts. The purpose of this study is to clarify the difference in edge artifacts in PET images using point spread function correction in 68Ga- and 18F-PET. Methods: We used a National Electrical Manufacturers Association International Electrotechnical Commission body phantom. The phantom was filled severally with 68Ga and 18F solution. The PET data were obtained over a 90 minutes period using a True Point Biograph 16 scanner. The images were then reconstructed with the ordered subset expectation maximization with point spread function correction. The phantom image analyses were performed by a visual assessment of the PET images and profiles, and an absolute recovery coefficient, which was the ratio of the maximum radioactivity of any given hot sphere to its true radioactivity. Results: The ring-like edge artifacts of 68Ga-PET were less prominent than those in 18F-PET. The relative radioactivity profiles of 68Ga-PET showed low overshoots of the maximum radioactivity although high overshoots did appear in 18F-PET. The absolute recovery coefficients of 68Ga-PET were smaller than those of 18F-PET. Conclusion: The edge artifacts of 68Ga-PET were less prominent than those of 18F-PET, and their overshoots were smaller. The difference in the positron range between 68Ga and 18F may possibly result in the difference in edge artifacts of images reconstructed using the point spread function correction algorithm.
- 1 November 2019
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 40 (11) , 1166-1173
Differences in edge artifacts between 68Ga- and 18F-PET images reconstructed using point spread function correction
Objective: Edge artifacts have been reported on in relation to 18F-PET using point spread function correction algorithms. The positron range of 68Ga is longer than 18F, and this difference is thought to result in different edge artifacts. The purpose of this study is to clarify the difference in edge artifacts in PET images using point spread function correction in 68Ga- and 18F-PET. Methods: We used a National Electrical Manufacturers Association International Electrotechnical Commission body phantom. The phantom was filled severally with 68Ga and 18F solution. The PET data were obtained over a 90 minutes period using a True Point Biograph 16 scanner. The images were then reconstructed with the ordered subset expectation maximization with point spread function correction. The phantom image analyses were performed by a visual assessment of the PET images and profiles, and an absolute recovery coefficient, which was the ratio of the maximum radioactivity of any given hot sphere to its true radioactivity. Results: The ring-like edge artifacts of 68Ga-PET were less prominent than those in 18F-PET. The relative radioactivity profiles of 68Ga-PET showed low overshoots of the maximum radioactivity although high overshoots did appear in 18F-PET. The absolute recovery coefficients of 68Ga-PET were smaller than those of 18F-PET. Conclusion: The edge artifacts of 68Ga-PET were less prominent than those of 18F-PET, and their overshoots were smaller. The difference in the positron range between 68Ga and 18F may possibly result in the difference in edge artifacts of images reconstructed using the point spread function correction algorithm.
- 1 March 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 47 (1) , 55-59
The Influence of Minimal Misalignment on the Repeatability of PET Images Examined by the Repositioning of Point Sources
We aimed to evaluate the influence of minimal misalignment of a hot spot on the repeatability of PET images using repositioning of point sources. Methods: Point sources with an inner diameter of 1 mm were made with 1 mu L of F-18 solution. Seven point sources were placed on the x-axis in the field of view. For fixed-position imaging, PET data were acquired for 10 min 5 times serially. For variable-position imaging, PET data were acquired for 10 min each with the point sources placed at 0, +/- 0.5, and +/- 1.0 mm in the x-axis direction. The data were reconstructed using ordered-subsets expectation maximization (OSEM) and OSEM plus point-spread function (PSF). The image matrix was 128 x 128, 200 x 200, 256 x 256, 400 x 400, and 512 x 512 pixels. The normalized maximum count (rMax), the coefficient of variance (CVmax), and the full width at half maximum were analyzed. Results: The hot spots on OSEM images far from the center became faint and broad, whereas those on OSEM + PSF images became small and dense. Although rMax was overestimated at the 5-cm position on OSEM images, rMax at other positions was overestimated on OSEM + PSF images with a matrix of at least 256 x 256. rMax showed a similar pattern in fixed-and variable-position images. CVmax in fixed-position OSEM images was less than 2%, irrespective of matrix size. In contrast, CVmax in variable-position images was higher than in fixed-position images. CVmax was higher for OSEM + PSF images than for OSEM images. The full width at half maximum increased at positions far from the center on OSEM images but was stable at all positions on OSEM + PSF images. Conclusion: The repeatability of the small hot spot was affected by the minimal misalignment, especially on OSEM + PSF images. Precise positioning is necessary if PET is to be used as a biomarker. Professionals should recognize that PSF correction worsens the repeatability of the small hot spot although improving the spatial resolution of PET images.
- 1 March 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 47 (1) , 55-59
The Influence of Minimal Misalignment on the Repeatability of PET Images Examined by the Repositioning of Point Sources
We aimed to evaluate the influence of minimal misalignment of a hot spot on the repeatability of PET images using repositioning of point sources. Methods: Point sources with an inner diameter of 1 mm were made with 1 mu L of F-18 solution. Seven point sources were placed on the x-axis in the field of view. For fixed-position imaging, PET data were acquired for 10 min 5 times serially. For variable-position imaging, PET data were acquired for 10 min each with the point sources placed at 0, +/- 0.5, and +/- 1.0 mm in the x-axis direction. The data were reconstructed using ordered-subsets expectation maximization (OSEM) and OSEM plus point-spread function (PSF). The image matrix was 128 x 128, 200 x 200, 256 x 256, 400 x 400, and 512 x 512 pixels. The normalized maximum count (rMax), the coefficient of variance (CVmax), and the full width at half maximum were analyzed. Results: The hot spots on OSEM images far from the center became faint and broad, whereas those on OSEM + PSF images became small and dense. Although rMax was overestimated at the 5-cm position on OSEM images, rMax at other positions was overestimated on OSEM + PSF images with a matrix of at least 256 x 256. rMax showed a similar pattern in fixed-and variable-position images. CVmax in fixed-position OSEM images was less than 2%, irrespective of matrix size. In contrast, CVmax in variable-position images was higher than in fixed-position images. CVmax was higher for OSEM + PSF images than for OSEM images. The full width at half maximum increased at positions far from the center on OSEM images but was stable at all positions on OSEM + PSF images. Conclusion: The repeatability of the small hot spot was affected by the minimal misalignment, especially on OSEM + PSF images. Precise positioning is necessary if PET is to be used as a biomarker. Professionals should recognize that PSF correction worsens the repeatability of the small hot spot although improving the spatial resolution of PET images.
- 1 October 2018
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 39 (10) , 936-944
Validation of scatter limitation correction to eliminate scatter correction error in oxygen-15 gas-inhalation positron emission tomography images
High levels of radioactivity inside a facemask cause scatter correction (SC) errors that appear as photopenic artifacts on quantitative oxygen-15 (15O) gas-inhalation positron emission tomography (PET) images. The present study aimed to validate the ability of scatter limitation correction (SLC) to eliminate SC errors in 15O gas-inhalation PET images acquired from patients and a phantom. We analyzed the SC errors in phantom images and calculated parametric images of the cerebral blood flow (CBF), cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2). Phantoms comprised a cylinder and paper with radioactivity to simulate a facemask during (15O)O2 gas inhalation. Parametric images were calculated from 15O gas-inhalation PET images of ten participants. All PET data were reconstructed using conventional SC as model-based SC and SLC. Images acquired from the phantoms and parametric images were assessed visually and quantitatively in the presence and absence of SC error. SC error was evident in images derived from the paper phantom and at the slice level of the cerebellum in CBF, OEF, and CMRO2 images. The radioactivity concentration in the cylindrical phantom with the paper phantom significantly improved with SLC. The SLC also increased the quantitative indices of CBF, OEF, and CMRO2 by 23.8, 42.2, and 44.4%, respectively. SLC visually eliminated the SC error and increased the quantitative parameters on 15O gas-inhalation images derived from a phantom and from patients.
- 1 October 2018
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 39 (10) , 936-944
Validation of scatter limitation correction to eliminate scatter correction error in oxygen-15 gas-inhalation positron emission tomography images
High levels of radioactivity inside a facemask cause scatter correction (SC) errors that appear as photopenic artifacts on quantitative oxygen-15 (15O) gas-inhalation positron emission tomography (PET) images. The present study aimed to validate the ability of scatter limitation correction (SLC) to eliminate SC errors in 15O gas-inhalation PET images acquired from patients and a phantom. We analyzed the SC errors in phantom images and calculated parametric images of the cerebral blood flow (CBF), cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2). Phantoms comprised a cylinder and paper with radioactivity to simulate a facemask during (15O)O2 gas inhalation. Parametric images were calculated from 15O gas-inhalation PET images of ten participants. All PET data were reconstructed using conventional SC as model-based SC and SLC. Images acquired from the phantoms and parametric images were assessed visually and quantitatively in the presence and absence of SC error. SC error was evident in images derived from the paper phantom and at the slice level of the cerebellum in CBF, OEF, and CMRO2 images. The radioactivity concentration in the cylindrical phantom with the paper phantom significantly improved with SLC. The SLC also increased the quantitative indices of CBF, OEF, and CMRO2 by 23.8, 42.2, and 44.4%, respectively. SLC visually eliminated the SC error and increased the quantitative parameters on 15O gas-inhalation images derived from a phantom and from patients.