Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting
- 24 February 2016
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (6) , 894-901
Abstract
Introduction Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Materials and Methods Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings. Results The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Conclusion Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.Keywords
Funding Information
- Nagase Landauer, LTD
This publication has 24 references indexed in Scilit:
- Radiation exposure in CT-guided interventionsEuropean Journal of Radiology, 2013
- Comparing Radiation Exposure Between Ablative Therapies for Small Renal MassesJournal of Endourology, 2013
- Technique for Creation of Artificial Pneumothorax for Pain Relief during Radiofrequency Ablation of Peripheral Lung Tumors: Report of Seven CasesJournal of Vascular and Interventional Radiology, 2011
- Hydrodisplacement in the Percutaneous Cryoablation of 50 Renal TumorsAmerican Journal of Roentgenology, 2010
- A survey of radiation dose to patients and operators during radiofrequency ablation using computed tomographyBiomedical Imaging and Intervention Journal, 2010
- CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and OperatorJournal of Vascular and Interventional Radiology, 2006
- Radiation Exposure to Operators during VertebroplastyJournal of Vascular and Interventional Radiology, 2005
- EVALUATION OF PATIENT AND STAFF DOSES DURING VARIOUS CT FLUOROSCOPY GUIDED INTERVENTIONSHealth Physics, 2003
- Patient and Personnel Exposure during CT Fluoroscopy-guided Interventional ProceduresRadiology, 2000
- Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance.American Journal of Roentgenology, 1999