Hiroyasu Fujiwara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroyasu Fujiwara has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hideo Gobara
Division of Medical Informatics, Okayama University Hospital, Okayama, Japan
14 shared publications - Susumu Kanazawa
Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
14 shared publications - Takao Hiraki
Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
14 shared publications - Toshihiro Iguchi
Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Okayama, Japan
12 shared publications - Yusuke Matsui
Okayama University Medical School
8 shared publications - Shinichi Toyooka
Okayama University Medical School
5 shared publications
Latest Publications
- 1 October 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (10) , 591-597
Short hookwire placement under imaging guidance before thoracic surgery: A review
- 1 October 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (10) , 591-597
Short hookwire placement under imaging guidance before thoracic surgery: A review
- 1 February 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (2) , 91-97
CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses
- 1 February 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (2) , 91-97
CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses
- 2 August 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (1) , 283-290
CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure
To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy.
- 2 August 2017
- Published by Springer Nature in European Radiology
- Vol. 28 (1) , 283-290
CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure
To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy.
- 1 July 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (7-8) , 535-541
Radiofrequency ablation of pulmonary tumors near the diaphragm
- 1 July 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (7-8) , 535-541
Radiofrequency ablation of pulmonary tumors near the diaphragm
- 1 November 2016
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 97 (11) , 1159-1164
Simultaneous biopsy and radiofrequency ablation of T1a renal cell carcinoma
- 1 November 2016
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 97 (11) , 1159-1164
Simultaneous biopsy and radiofrequency ablation of T1a renal cell carcinoma
- 24 February 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (6) , 894-901
Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting
Introduction Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Materials and Methods Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings. Results The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Conclusion Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.
- 24 February 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (6) , 894-901
Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting
Introduction Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Materials and Methods Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings. Results The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Conclusion Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.
- 1 November 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (11) , 2202-2209
Fever after lung radiofrequency ablation: Prospective evaluation of its incidence and associated factors
- 1 November 2015
- Published by Elsevier in European Journal of Radiology
- Vol. 84 (11) , 2202-2209
Fever after lung radiofrequency ablation: Prospective evaluation of its incidence and associated factors
- 20 May 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (1) , 114-121
CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax
To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P = 0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. • Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. • Complications are usually minor and asymptomatic. • A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.
- 20 May 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (1) , 114-121
CT fluoroscopy-guided preoperative short hook wire placement for small pulmonary lesions: evaluation of safety and identification of risk factors for pneumothorax
To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P = 0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. • Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. • Complications are usually minor and asymptomatic. • A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.
- 15 May 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1346-1348
Tension Pneumopericardium as a Complication of Preoperative Localization of a Small Pulmonary Metastasis Using a Short Hook Wire and Suture System
- 15 May 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1346-1348
Tension Pneumopericardium as a Complication of Preoperative Localization of a Small Pulmonary Metastasis Using a Short Hook Wire and Suture System
- 21 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1376-1379
Retained Short Hook Wires Used for Preoperative Localization of Small Pulmonary Lesions During Video-Assisted Thoracoscopic Surgery: A Report of 2 Cases
- 21 March 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (5) , 1376-1379
Retained Short Hook Wires Used for Preoperative Localization of Small Pulmonary Lesions During Video-Assisted Thoracoscopic Surgery: A Report of 2 Cases