A New Approach to Contour Detection in X-Ray Arteriograms
- 1 August 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 40 (8) , 514-520
Abstract
We sought to develop a novel approach (the Wavecontour) for the detection of contours in vascular x-ray images, designed to eliminate any systematic underestimation or overestimation for vessel sizes in the range of 0.5 to 15 mm and further minimize the influence of the user-defined start points and end points. This method is based on the Wavefront Propagation principle in a 2-stage approach. Two validation experiments were performed: a Plexiglas phantom study (tube sizes ranging from 0.51 to 9.9 mm) and an in vivo patient study (114 patients with various degrees of stenosis). The phantom study demonstrated an accuracy of 0.007 mm and a precision of 0.072 mm. The patient study showed a high similarity between the detected and the expert-drawn contours: 93% for a threshold of 1.0 pixel and 81% for a threshold of 0.5 pixels. Furthermore, the contours are robust in complex lesions and are almost independent in the middle part of the segment from the user-defined start point and end point. A variation of only 0.6 pixels exists in the middle 60% of the contours. Our new Wavecontour approach performs very well on phantom images as well as on clinical data over the whole range of 0.5 to 15 mm and results in more robust QCA/QVA analyses.Keywords
This publication has 21 references indexed in Scilit:
- Quantitative Assessment of the Morphology of Renal Arteries from X-ray ImagesInvestigative Radiology, 2004
- Fuzzy vector median-based surface smoothingIEEE Transactions on Visualization and Computer Graphics, 2004
- A new model-based technique for enhanced small-vessel measurements in X-ray cine-angiogramsIEEE Transactions on Medical Imaging, 2000
- Derivation of optimal filters for the detection of coronary arteriesIEEE Transactions on Medical Imaging, 1998
- A new approach for the quantification of complex lesion morphology: The gradient field transform; Basic principles and validation resultsJACC, 1994
- In‐vivo validation of on‐line and off‐line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteriesCatheterization and Cardiovascular Diagnosis, 1992
- Absolute diameter measurements of coronary arteries based on the first zero crossing of the Fourier spectrumMedical Physics, 1989
- Cross-Sectional Area Measurements by Digital Subtraction VideodensitometryInvestigative Radiology, 1986
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devicesMedical Physics, 1981