JJJohannes P. Janssen

Johannes P. Janssen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Johannes P. Janssen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Gerhard Koning

    Division of Image Processing (LKEB), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

    3 shared publications
  • Joan C. Tuinenburg

    Division of Image Processing (LKEB), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

    3 shared publications
  • Johan H. C. Reiber

    Division of Image Processing (LKEB), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

    2 shared publications
  • Alexandra J. Lansky

    Columbia University Medical Center and Cardiovascular Research Foundation, New York, USA

    1 shared publication
  • Andrei Rares

    Division of Image Processing (LKEB), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

    1 shared publication
  • Gerhard Koning

    Leiden University Medical Center

    1 shared publication

Latest Publications

  • Open Access

    New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis

    by Johannes P. Janssen, Andrei Rares, Joan C. Tuinenburg, Gerhard Koning, Alexandra J. Lansky, Johan H. C. Reiber

    This paper presents new approaches for the assessment of the arterial and reference diameters in (cardio-)vascular X-ray images, designed to overcome the problems experienced in conventional quantitative coronary and vascular angiography approaches. In single or “straight” vessel segments, the arterial and reference diameter directions were made independent of each other in order to be able to measure the minimal lumen diameter (MLD) more accurately, especially in curved vessel segments. For ostial segments, an extension of this approach was used, to allow measurement of ostial lesions in sidebranches more proximal than using conventional methods. Furthermore, two new bifurcation approaches were developed. The validation study shows that the straight segment approach results in significant smaller MLDs (on average 0.032 mm) and the ostial approach achieves on average an increase in %DS of 3.8% and an increase in lesion length of 0.59 mm due to loosening the directional constraint. The validation of our new bifurcation approaches in phantom data as well as clinical data shows only small differences between pre- and post-intervention measurements of the reference diameters outside the bifurcation core (errors smaller than 0.06 mm) and the bifurcation core area (errors smaller than 1.4% for phantom data). In summary, these new approaches have led to further improvements in the quantitative analyses of (cardio-)vascular X-ray angiographies.


  • A New Approach to Contour Detection in X-Ray Arteriograms

    by Johannes P. Janssen, Gerhard Koning, Patrick J. H. de Koning, Johan G. Bosch, Joan C. Tuinenburg, Johan H. C. Reiber

    We sought to develop a novel approach (the Wavecontour) for the detection of contours in vascular x-ray images, designed to eliminate any systematic underestimation or overestimation for vessel sizes in the range of 0.5 to 15 mm and further minimize the influence of the user-defined start points and end points. This method is based on the Wavefront Propagation principle in a 2-stage approach. Two validation experiments were performed: a Plexiglas phantom study (tube sizes ranging from 0.51 to 9.9 mm) and an in vivo patient study (114 patients with various degrees of stenosis). The phantom study demonstrated an accuracy of 0.007 mm and a precision of 0.072 mm. The patient study showed a high similarity between the detected and the expert-drawn contours: 93% for a threshold of 1.0 pixel and 81% for a threshold of 0.5 pixels. Furthermore, the contours are robust in complex lesions and are almost independent in the middle part of the segment from the user-defined start point and end point. A variation of only 0.6 pixels exists in the middle 60% of the contours. Our new Wavecontour approach performs very well on phantom images as well as on clinical data over the whole range of 0.5 to 15 mm and results in more robust QCA/QVA analyses.


  • Validation of a New Method for the Detection of Pathlines in Vascular X-ray Images

    by Johannes P. Janssen, Gerhard Koning, Patrick J. H. de Koning, Joan C. Tuinenburg, Johan H. C. Reiber

    This article presents the validation of a new pathline approach, based on the wavefront propagation principle, on a large variety of vascular images. The purpose of the novel approach, called wavepath, was to minimize the variability of the measurements in the quantitative vascular analysis by reducing the variability that is introduced by manually placing the start and end points of the vessel segment. This results in a robust and reproducible pathline detection that is subsequently used in the analysis and lesion quantification. The validation study that was performed concerned a large variety of vessel segments and showed that the approach results in a pathline that is totally constant in its middle part. This holds not only for the straight segment version but also for the bifurcation version and ostial version of the algorithm. Moreover, the average number of additional points per pathline needed to guide the wavepath through the correct vessel is minimized to 0 for the straight segments, 0.06 for aortic bifurcations, 0.25 for carotid bifurcations, and 0.08 for the ostial segments. In conclusion, our new approach performs very well in all types of vascular x-ray images, resulting in a stable and robust pathline detection.


  • A novel approach for the detection of pathlines in X-Ray angiograms: the wavefront propagation algorithm

    by Johannes P. Janssen, Gerhard Koning, Patrick J.H. de Koning, Joan C. Tuinenburg, Johan H.C. Reiber

    This article presents a new pathline approach, based on the wavefront propagation principle, and developed in order to reduce the variability in the outcomes of the quantitative coronary artery...