Development of aorta‐to‐right atrial fistula following closure of secundum atrial septal defect using the Amplatzer septal occluder
Authors:
- 27 January 2003
- journal article
- case report
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (2) , 246-251
Abstract
An aorta‐to‐right atrial fistula developed within 3 months after closure of an atrial septal defect using the Amplatzer septal occluder. Surgical correction was required. The cause of this complication appears to be erosion into the aorta by the right atrial disk. Cathet Cardiovasc Intervent 2003;58:246–251.Keywords
This publication has 8 references indexed in Scilit:
- Morphological Assessment of Left Ventricular Thrombus by Live Three‐Dimensional Transthoracic EchocardiographyEchocardiography, 2004
- Morphological variations of secundum‐type atrial septal defects: Feasibility for percutaneous closure using Amplatzer septal occludersCatheterization and Cardiovascular Interventions, 2001
- Percutaneous Closure of Large Atrial Septal Defects with the Amplatzer Septal Occluder: Technical Overkill or Recommendable Alternative Treatment?Journal of Interventional Cardiology, 2001
- Transvenous closure of moderate and large secundum atrial septal defects in adults using the Amplatzer septal occluderCatheterization and Cardiovascular Interventions, 2001
- Treatment of atrial septal defects in symptomatic children aged less than 2 years of age using the Amplatzer septal occluderCardiology in the Young, 2000
- Comparison of results and complications of surgical and amplatzer device closure of atrial septal defectsThe Journal of Thoracic and Cardiovascular Surgery, 1999
- Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experienceHeart, 1999
- Closure of Atrial Septal Defects With the Amplatzer Occlusion Device: Preliminary ResultsJACC, 1998