Mark H. Hoyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark H. Hoyer has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Kali A. Hopkins
Department of Pediatrics, Section of Pediatric Cardiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois
2 shared publications- Nicholas B. Zaban
Division of Pediatric Cardiology, Department of Pediatrics, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, IN, USA
2 shared publications W. Aaron Kay
Department of Pediatrics, Division of Pediatric Cardiology, Indiana University School of Medicine, Indianapolis, Indiana
2 shared publications- Aditya P. Desai
Indiana University School of Medicine, Indianapolis, Indianapolis, USA
1 shared publication Ahmad Moustapha
Section of Cardiovascular Surgery, Department of Surgery, Indiana University School of Medicine, Indianapolis, Indiana
1 shared publicationAshley A. Detzner
Indiana University School of Medicine, Indianapolis, Indiana
1 shared publication
Latest Publications
- 27 May 2023
- Published by Springer Nature in Pediatric Cardiology
- Vol. 45 (7) , 1455-1460
Coarctation Angioplasty in Young Children: Does IMPACT Registry Data Accurately Reflect Clinical Outcomes?
Balloon angioplasty for recoarctation of the aorta is routinely performed in young children and is considered successful when the systolic gradient is reduced to < 10 mmHg. IMPACT defines acute procedural success solely based on a final gradient of < 10 mmHg and stratifies participating institutions based on these acute outcomes. Between February 2012 and December 2020, IMPACT data was analyzed for 110 coarctation interventions. Electronic medical records were reviewed, and primary endpoints were one of the following: (1) final analysis end date (June 2021), (2) patient death, or (3) most recent transcatheter or surgical reintervention. 64 (58.2%) interventions had a post-procedure CA gradient < 10 mmHg. Comparison of clinical patient outcome for acute success demonstrated no significant relationship using IMPACT (p = 0.70) criteria. There was no statistically significant difference between clinical success and failure for: pre- and post-treatment systolic gradients; absolute or percent change in systolic gradient; and pre-treatment aorta diameter. Clinical outcome and patient age did show a significant difference (p = 0.0093) with better clinical outcomes in older patients. Our analysis did not reveal a statistically significant difference between IMPACT criteria for successful treatment of CA and clinical outcome. These findings underscore a need to identify other clinical metrics that better predict outcome following CA balloon angioplasty treatment.
- 27 May 2023
- Published by Springer Nature in Pediatric Cardiology
- Vol. 45 (7) , 1455-1460
Coarctation Angioplasty in Young Children: Does IMPACT Registry Data Accurately Reflect Clinical Outcomes?
Balloon angioplasty for recoarctation of the aorta is routinely performed in young children and is considered successful when the systolic gradient is reduced to < 10 mmHg. IMPACT defines acute procedural success solely based on a final gradient of < 10 mmHg and stratifies participating institutions based on these acute outcomes. Between February 2012 and December 2020, IMPACT data was analyzed for 110 coarctation interventions. Electronic medical records were reviewed, and primary endpoints were one of the following: (1) final analysis end date (June 2021), (2) patient death, or (3) most recent transcatheter or surgical reintervention. 64 (58.2%) interventions had a post-procedure CA gradient < 10 mmHg. Comparison of clinical patient outcome for acute success demonstrated no significant relationship using IMPACT (p = 0.70) criteria. There was no statistically significant difference between clinical success and failure for: pre- and post-treatment systolic gradients; absolute or percent change in systolic gradient; and pre-treatment aorta diameter. Clinical outcome and patient age did show a significant difference (p = 0.0093) with better clinical outcomes in older patients. Our analysis did not reveal a statistically significant difference between IMPACT criteria for successful treatment of CA and clinical outcome. These findings underscore a need to identify other clinical metrics that better predict outcome following CA balloon angioplasty treatment.
- 1 April 2020
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 30 (4) , 489-492
Short- and intermediate-term results of balloon aortic valvuloplasty and surgical aortic valvotomy in neonates
Background: Balloon aortic valvuloplasty and open surgical valvotomy are procedures to treat neonatal aortic stenosis, and there is controversy as to which method has superior outcomes. Methods: We reviewed the records of patients at our institution since 2000 who had a balloon aortic valvuloplasty or surgical valvotomy via an open commissurotomy prior to 2 months of age. Results: Forty patients had balloon aortic valvuloplasty and 15 patients had surgical valvotomy via an open commissurotomy. There was no difference in post-procedure mean gradient by transthoracic echocardiogram, which were 25.8 mmHg for balloon aortic valvuloplasty and 26.2 mmHg for surgical valvotomy, p = 0.87. Post-procedure, 15% of balloon aortic valvuloplasty patients had moderate aortic insufficiency and 2.5% of patients had severe aortic insufficiency, while no surgical valvotomy patients had moderate or severe aortic insufficiency. The average number of post-procedure hospital days was 14.2 for balloon aortic valvuloplasty and 19.8 for surgical valvotomy (p = 0.52). Freedom from re-intervention was 69% for balloon aortic valvuloplasty and 67% for surgical valvotomy at 1 year, and 43% for balloon aortic valvuloplasty and 67% for surgical valvotomy at 5 years (p = 0.60). Conclusions: Balloon aortic valvuloplasty and surgical valvotomy provide similar short-term reduction in valve gradient. Balloon aortic valvuloplasty has a slightly shorter but not statistically significant hospital stay. Freedom from re-intervention is similar at 1 year. At 5 years, it is slightly higher in surgical valvotomy, though not statistically different. Balloon aortic valvuloplasty had a higher incidence of significant aortic insufficiency. Long-term comparisons cannot be made given the lack of long-term follow-up with surgical valvotomy.
- 1 April 2020
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 30 (4) , 489-492
Short- and intermediate-term results of balloon aortic valvuloplasty and surgical aortic valvotomy in neonates
Background: Balloon aortic valvuloplasty and open surgical valvotomy are procedures to treat neonatal aortic stenosis, and there is controversy as to which method has superior outcomes. Methods: We reviewed the records of patients at our institution since 2000 who had a balloon aortic valvuloplasty or surgical valvotomy via an open commissurotomy prior to 2 months of age. Results: Forty patients had balloon aortic valvuloplasty and 15 patients had surgical valvotomy via an open commissurotomy. There was no difference in post-procedure mean gradient by transthoracic echocardiogram, which were 25.8 mmHg for balloon aortic valvuloplasty and 26.2 mmHg for surgical valvotomy, p = 0.87. Post-procedure, 15% of balloon aortic valvuloplasty patients had moderate aortic insufficiency and 2.5% of patients had severe aortic insufficiency, while no surgical valvotomy patients had moderate or severe aortic insufficiency. The average number of post-procedure hospital days was 14.2 for balloon aortic valvuloplasty and 19.8 for surgical valvotomy (p = 0.52). Freedom from re-intervention was 69% for balloon aortic valvuloplasty and 67% for surgical valvotomy at 1 year, and 43% for balloon aortic valvuloplasty and 67% for surgical valvotomy at 5 years (p = 0.60). Conclusions: Balloon aortic valvuloplasty and surgical valvotomy provide similar short-term reduction in valve gradient. Balloon aortic valvuloplasty has a slightly shorter but not statistically significant hospital stay. Freedom from re-intervention is similar at 1 year. At 5 years, it is slightly higher in surgical valvotomy, though not statistically different. Balloon aortic valvuloplasty had a higher incidence of significant aortic insufficiency. Long-term comparisons cannot be made given the lack of long-term follow-up with surgical valvotomy.
- Open Access
- 1 January 2020
- Published by Elsevier in JACC: Case Reports
- Vol. 2 (1) , 135-138
Successful TPV Implantation in a Pregnant Patient With Right Ventricle to Pulmonary Artery Conduit Obstruction
- 1 January 2020
- Published by Elsevier in JACC: Case Reports
- Vol. 2 (1) , 135-138
Open AccessSuccessful TPV Implantation in a Pregnant Patient With Right Ventricle to Pulmonary Artery Conduit Obstruction
- Open Access
- 1 January 2020
- Published by Elsevier in JACC: Case Reports
- Vol. 2 (1) , 116-119
Management of Severe Coarctation of the Aorta During Pregnancy
- 1 January 2020
- Published by Elsevier in JACC: Case Reports
- Vol. 2 (1) , 116-119
Open AccessManagement of Severe Coarctation of the Aorta During Pregnancy
- 10 September 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (11) , 1407-1409
Early and late presentation of coronary artery fistula: a possible natural progression?
We present two patients, one 10 years old and another 43 years old, who both had successful transcatheter closure of left main coronary artery to right atrium fistulas. The older patient had a larger fistula as well as more symptoms and a complicated post-procedure course. Closure of medium or large coronary artery fistulas should be considered at younger ages to minimise future complications.
- 10 September 2019
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 29 (11) , 1407-1409
Early and late presentation of coronary artery fistula: a possible natural progression?
We present two patients, one 10 years old and another 43 years old, who both had successful transcatheter closure of left main coronary artery to right atrium fistulas. The older patient had a larger fistula as well as more symptoms and a complicated post-procedure course. Closure of medium or large coronary artery fistulas should be considered at younger ages to minimise future complications.
- 16 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (4) , 531-537
Single pediatric center experience with multiple device implantation for complex secundum atrial septal defects
Objectives: We analyzed the efficacy and complications of placing multiple transcatheter devices to correct complex ASD in a primarily pediatric population. Background: Limited pediatric information exists regarding the safety and efficacy of using multiple devices for secundum atrial septal defects (ASD) when multiple defects are present. Methods: Cath lab, echo, and clinical data were reviewed for 238 patients who underwent device closure of secundum ASD from 2000 to 2007 at a single pediatric center. Of those requiring multiple devices (n = 15), residual shunting and complications were assessed. Results: 238 patients (mean age 12 yrs; 80% < 16 yrs) underwent transcatheter ASD closure. 34 (14%) had multiple ASD, but only 15 received multiple devices (2 devices in 14 and 3 devices in 1). The mean age and weight (12 yrs; 35 kg) represent a younger population than previously reported. Only 3 were > 15 yrs, with a median age of 10.8 yrs (range 2–31). There was no compromise or obstruction to surrounding structures, and no device embolization or erosion was noted. A tiny thrombus was observed on the right sided screw of one device with no clinical sequelae. One patient (age 31 yrs) died at home 30 days post procedure from cardiac tamponade. Autopsy revealed the 3 intact devices in stable position without evidence of erosion. Latest available echo follow-up for the group revealed functional resolution of atrial level shunting in all patients. Conclusion: Multiple devices can safely and effectively be implanted in the pediatric population to close complex ASD.
- 16 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (4) , 531-537
Single pediatric center experience with multiple device implantation for complex secundum atrial septal defects
Objectives: We analyzed the efficacy and complications of placing multiple transcatheter devices to correct complex ASD in a primarily pediatric population. Background: Limited pediatric information exists regarding the safety and efficacy of using multiple devices for secundum atrial septal defects (ASD) when multiple defects are present. Methods: Cath lab, echo, and clinical data were reviewed for 238 patients who underwent device closure of secundum ASD from 2000 to 2007 at a single pediatric center. Of those requiring multiple devices (n = 15), residual shunting and complications were assessed. Results: 238 patients (mean age 12 yrs; 80% < 16 yrs) underwent transcatheter ASD closure. 34 (14%) had multiple ASD, but only 15 received multiple devices (2 devices in 14 and 3 devices in 1). The mean age and weight (12 yrs; 35 kg) represent a younger population than previously reported. Only 3 were > 15 yrs, with a median age of 10.8 yrs (range 2–31). There was no compromise or obstruction to surrounding structures, and no device embolization or erosion was noted. A tiny thrombus was observed on the right sided screw of one device with no clinical sequelae. One patient (age 31 yrs) died at home 30 days post procedure from cardiac tamponade. Autopsy revealed the 3 intact devices in stable position without evidence of erosion. Latest available echo follow-up for the group revealed functional resolution of atrial level shunting in all patients. Conclusion: Multiple devices can safely and effectively be implanted in the pediatric population to close complex ASD.
- 8 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (1) , 162-164
Delivery sheath tear after modification for ASD closure
During transcatheter closure of an atrial septal defect with insufficient aortic rim, a standard delivery sheath was modified by cutting a bevel at the distal tip to improve device orientation. The sheath split longitudinally when attempting to recapture the closure device. Troubleshooting allowed a device to be implanted successfully. Pitfalls regarding our sheath modification and methods to overcome prolapse of the left atrial disk into the right atrium are discussed.
- 8 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (1) , 162-164
Delivery sheath tear after modification for ASD closure
During transcatheter closure of an atrial septal defect with insufficient aortic rim, a standard delivery sheath was modified by cutting a bevel at the distal tip to improve device orientation. The sheath split longitudinally when attempting to recapture the closure device. Troubleshooting allowed a device to be implanted successfully. Pitfalls regarding our sheath modification and methods to overcome prolapse of the left atrial disk into the right atrium are discussed.
- 1 August 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 65 (4) , 577-580
Novel use of the Amplatzer plug for closure of a patent ductus arteriosus
We report the novel use of an Amplatzer vascular plug for closure of a large tubular patent ductus arteriosus in a small child.
- 1 August 2005
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 65 (4) , 577-580
Novel use of the Amplatzer plug for closure of a patent ductus arteriosus
We report the novel use of an Amplatzer vascular plug for closure of a large tubular patent ductus arteriosus in a small child.
- 27 January 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (2) , 246-251
Development of aorta‐to‐right atrial fistula following closure of secundum atrial septal defect using the Amplatzer septal occluder
An aorta‐to‐right atrial fistula developed within 3 months after closure of an atrial septal defect using the Amplatzer septal occluder. Surgical correction was required. The cause of this complication appears to be erosion into the aorta by the right atrial disk. Cathet Cardiovasc Intervent 2003;58:246–251.
- 27 January 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (2) , 246-251
Development of aorta‐to‐right atrial fistula following closure of secundum atrial septal defect using the Amplatzer septal occluder
An aorta‐to‐right atrial fistula developed within 3 months after closure of an atrial septal defect using the Amplatzer septal occluder. Surgical correction was required. The cause of this complication appears to be erosion into the aorta by the right atrial disk. Cathet Cardiovasc Intervent 2003;58:246–251.