Residual total protein and total organic carbon levels on reprocessed gastrointestinal (GI) biopsy forceps
- 5 September 2008
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 89B (1) , 172-176
Abstract
Many single‐use (disposable) devices are reprocessed between patient uses. In the past, a visual determination was considered the endpoint of “clean” for cleaned reusable devices. In this report, we measured quantitative endpoints by measuring residual total protein and residual total organic carbon before and after cleaning with commercially available cleaners for medical devices on 15 single‐use gastrointestinal biopsy forceps inoculated with a three‐protein test soil before and after cleaning. Each device was extracted separately and tested using Bradford's reagent for total protein and a direct digestion method for total organic carbon. Data for pre‐ and post‐cleaned devices were generated for all five cleaning cycles. The highest amounts of residual total protein and total organic carbon found on precleaned devices were 61.8 μg/cm2 and 39.1 μg/cm2, respectively, on the outer surfaces. The highest amounts of residual total protein and total organic carbon on postcleaned device extracts were 4.0 μg/cm2 and 2.2 μg/cm2, respectively, on the outer surfaces. All postcleaned devices were visually clean. Our results provide quantitative total protein and total organic carbon levels for cleaned single‐use biopsy forceps. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009Keywords
This publication has 19 references indexed in Scilit:
- Assessment of Reprocessed Arthroscopic Shaver BladesArthroscopy, 2006
- Nosocomial outbreak of Pseudomonas aeruginosa infections related to a flexible bronchoscopeJournal of Hospital Infection, 2006
- Surface decontamination of surgical instruments: an ongoing dilemmaJournal of Hospital Infection, 2006
- Quantitative analysis of residual protein contamination on reprocessed surgical instrumentsJournal of Hospital Infection, 2006
- Rapid method for the sensitive detection of protein contamination on surgical instrumentsJournal of Hospital Infection, 2006
- Decontaminated Single-Use Devices: An Oxymoron That May Be Placing Patients at Risk for Cross-ContaminationInfection Control & Hospital Epidemiology, 2001
- Worst-case soiling levels for patient-used flexible endoscopes before and after cleaningAmerican Journal of Infection Control, 1999
- Disinfection of Endoscopes: Review of New Chemical Sterilants Used for High-Level DisinfectionInfection Control & Hospital Epidemiology, 1999
- What standards should we use for the disinfection of large equipment?Journal of Hospital Infection, 1991
- A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye bindingAnalytical Biochemistry, 1976