Victoria M. Hitchins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Victoria M. Hitchins has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Anne D. Lucas
U.S. Food and Drug Administration, Silver Spring, Maryland
2 shared publications Edward A. Gordon
2 shared publicationsAnne D. Lucas
1 shared publication- Elaine Daniell1 shared publication
- Joyce M. Hansen
Joyce M Hansen, BS, MBA, is vice president of microbiological quality & sterility assurance at Johnson & Johnson in Raritan, NJ, and chair of the 2022 Kilmer Conference
1 shared publication - Kathryn M. Gold
Division of Biology, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD
1 shared publication
Latest Publications
- 8 April 2016
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (5) , 1210-1215
Bacterial endotoxin detection in hyaluronic acid-based medical devices
A simple and rapid method has been developed for testing bacterial endotoxin in hyaluronic acid (HA)-based medical devices. High-molecular-weight HA (HMW HA) in solution or HA-based medical devices was digested by the enzyme hyaluronidase to reduce solution viscosity by truncating the long chains of HA and to test for bacterial endotoxin. The bacterial endotoxin level was detected and measured by kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The method was applied to two different ophthalmic viscosurgical devices (OVDs) and one dermal filler, and may easily be adapted to use with up to 3% HA solutions and other HA-based medical devices. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. J Biomed Mater Res Part B: Appl Biomater, 2016. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1210–1215, 2017.
- 8 April 2016
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 105 (5) , 1210-1215
Bacterial endotoxin detection in hyaluronic acid-based medical devices
A simple and rapid method has been developed for testing bacterial endotoxin in hyaluronic acid (HA)-based medical devices. High-molecular-weight HA (HMW HA) in solution or HA-based medical devices was digested by the enzyme hyaluronidase to reduce solution viscosity by truncating the long chains of HA and to test for bacterial endotoxin. The bacterial endotoxin level was detected and measured by kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The method was applied to two different ophthalmic viscosurgical devices (OVDs) and one dermal filler, and may easily be adapted to use with up to 3% HA solutions and other HA-based medical devices. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. J Biomed Mater Res Part B: Appl Biomater, 2016. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1210–1215, 2017.
- 2 April 2016
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 50 (s3) , 35-43
Product Sterility Testing . . . To Test or Not to Test? That Is the Question
The applications for sterility testing in the validation and routine control of sterilization of medical devices have changed dramatically over the years. As the definition of sterility assurance has evolved, so has the state of the science associated with product sterility testing. Historically, product sterility testing has been applied to such things as sterilization validation, sterilization lot release, packaging qualification, aseptic processing qualification, and determination of shelf life for the packaged medical device. In most of these cases, however, the results obtained from performing sterility testing on products do not provide the desired confirmation and assurance. Utilizing sterility testing on fully processed finished product is not appropriate for determination of sterilization process effectiveness, sterility assurance level, package integrity, or shelf life. The industry has developed more robust methods for validation of these applications to assure sterility and package pe...
- 2 April 2016
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 50 (s3) , 35-43
Product Sterility Testing . . . To Test or Not to Test? That Is the Question
The applications for sterility testing in the validation and routine control of sterilization of medical devices have changed dramatically over the years. As the definition of sterility assurance has evolved, so has the state of the science associated with product sterility testing. Historically, product sterility testing has been applied to such things as sterilization validation, sterilization lot release, packaging qualification, aseptic processing qualification, and determination of shelf life for the packaged medical device. In most of these cases, however, the results obtained from performing sterility testing on products do not provide the desired confirmation and assurance. Utilizing sterility testing on fully processed finished product is not appropriate for determination of sterilization process effectiveness, sterility assurance level, package integrity, or shelf life. The industry has developed more robust methods for validation of these applications to assure sterility and package pe...
- 2 October 2015
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 49 (5) , 354-362
Evaluating Device Design and Cleanability of Orthopedic Device Models Contaminated with a Clinically Relevant Bone Test Soil
Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. Methods: The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. Results: The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained signi...
- 2 October 2015
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 49 (5) , 354-362
Evaluating Device Design and Cleanability of Orthopedic Device Models Contaminated with a Clinically Relevant Bone Test Soil
Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. Methods: The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. Results: The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained signi...
- 1 July 2013
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 47 (4) , 343-346
Lack of Correlation between Age and/or Gender with the Force Utilized in Cleaning an Anesthesia Machine
Several human factors influence the cleaning of reusable medical devices and equipment. This study evaluated whether a correlation exists between age and/or gender of a person cleaning, with the force applied to remove artificial blood soil on the surface of an anesthesia machine. The findings from this study may be used to increase our understanding of human factors in the cleaning of reusable medical equipment and suggest improvements in equipment design to address issues of concern.
- 1 July 2013
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 47 (4) , 343-346
Lack of Correlation between Age and/or Gender with the Force Utilized in Cleaning an Anesthesia Machine
Several human factors influence the cleaning of reusable medical devices and equipment. This study evaluated whether a correlation exists between age and/or gender of a person cleaning, with the force applied to remove artificial blood soil on the surface of an anesthesia machine. The findings from this study may be used to increase our understanding of human factors in the cleaning of reusable medical equipment and suggest improvements in equipment design to address issues of concern.
- 1 January 2012
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 46 (sp12) , 61-67
Quantification by Mass Of Residual Debris in Reusable Medical Devices
- 1 January 2012
- Published by Association for the Advancement of Medical Instrumentation (AAMI) in Biomedical Instrumentation & Technology
- Vol. 46 (sp12) , 61-67
Quantification by Mass Of Residual Debris in Reusable Medical Devices
- 4 December 2008
- Published by Springer Nature in Biomedical Microdevices
- Vol. 12 (4) , 569-573
What we know and don’t know about the bioeffects of nanoparticles: developing experimental approaches for safety assessment
The Center for Devices and Radiological Health (CDRH) of the US Food and Drug Administration (FDA) regulates nano-based medical products and therefore is required to address the safety and biological effects of nano-scale materials used in these products. Both in vitro and in vivo toxicological research studies are being conducted at the FDA to help determine the risks versus benefits of these new products. This article will briefly summarize some of the initial research findings from FDA-CDRH studies using TiO2, polystyrene, and silicon nanoparticles.
- 4 December 2008
- Published by Springer Nature in Biomedical Microdevices
- Vol. 12 (4) , 569-573
What we know and don’t know about the bioeffects of nanoparticles: developing experimental approaches for safety assessment
The Center for Devices and Radiological Health (CDRH) of the US Food and Drug Administration (FDA) regulates nano-based medical products and therefore is required to address the safety and biological effects of nano-scale materials used in these products. Both in vitro and in vivo toxicological research studies are being conducted at the FDA to help determine the risks versus benefits of these new products. This article will briefly summarize some of the initial research findings from FDA-CDRH studies using TiO2, polystyrene, and silicon nanoparticles.
- 5 September 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 89B (1) , 172-176
Residual total protein and total organic carbon levels on reprocessed gastrointestinal (GI) biopsy forceps
Many single‐use (disposable) devices are reprocessed between patient uses. In the past, a visual determination was considered the endpoint of “clean” for cleaned reusable devices. In this report, we measured quantitative endpoints by measuring residual total protein and residual total organic carbon before and after cleaning with commercially available cleaners for medical devices on 15 single‐use gastrointestinal biopsy forceps inoculated with a three‐protein test soil before and after cleaning. Each device was extracted separately and tested using Bradford's reagent for total protein and a direct digestion method for total organic carbon. Data for pre‐ and post‐cleaned devices were generated for all five cleaning cycles. The highest amounts of residual total protein and total organic carbon found on precleaned devices were 61.8 μg/cm2 and 39.1 μg/cm2, respectively, on the outer surfaces. The highest amounts of residual total protein and total organic carbon on postcleaned device extracts were 4.0 μg/cm2 and 2.2 μg/cm2, respectively, on the outer surfaces. All postcleaned devices were visually clean. Our results provide quantitative total protein and total organic carbon levels for cleaned single‐use biopsy forceps. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
- 5 September 2008
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 89B (1) , 172-176
Residual total protein and total organic carbon levels on reprocessed gastrointestinal (GI) biopsy forceps
Many single‐use (disposable) devices are reprocessed between patient uses. In the past, a visual determination was considered the endpoint of “clean” for cleaned reusable devices. In this report, we measured quantitative endpoints by measuring residual total protein and residual total organic carbon before and after cleaning with commercially available cleaners for medical devices on 15 single‐use gastrointestinal biopsy forceps inoculated with a three‐protein test soil before and after cleaning. Each device was extracted separately and tested using Bradford's reagent for total protein and a direct digestion method for total organic carbon. Data for pre‐ and post‐cleaned devices were generated for all five cleaning cycles. The highest amounts of residual total protein and total organic carbon found on precleaned devices were 61.8 μg/cm2 and 39.1 μg/cm2, respectively, on the outer surfaces. The highest amounts of residual total protein and total organic carbon on postcleaned device extracts were 4.0 μg/cm2 and 2.2 μg/cm2, respectively, on the outer surfaces. All postcleaned devices were visually clean. Our results provide quantitative total protein and total organic carbon levels for cleaned single‐use biopsy forceps. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009