To avoid highly invasive cement extraction during revision of cemented hip stems, we investigated in vitro a concept for refixation of loosened cemented stems using induction heating. The thermoplastic polymeric bone cement is softened by heating the metallic stem above the cement’s glass transition temperature, possibly allowing refixation. In an exploratory study three simplified conical Co28Cr6Mo samples were corundum blasted to simulate the surface roughness of matt cemented stems. Three fixation states were produced by cementing the stem samples within a PMMA cavity: (1) initially implanted stem after cement polymerization; (2) loosened stem retained by taper self-locking; (3) refixated stem. The latter should be achieved by inductive surface heating to 95 °C and applying an axial force of 2 kN. Fixation quality was assessed from relative motions in the stem-cement interface, acoustic emissions during quasistatic torsional loading (7 Nm and 10 Nm), and axial pull-out forces of the stem from the cement mantle. Initial fixation yielded a pull-out force of F PO = 1.99 kN ± 0.26 kN, decreasing to 0.84 kN ± 0.38 kN after loosening. After refixation, pull-out forces reached 0.89 kN ± 0.50 kN. However, in one of the three samples, the pull-out force could be restored by refixation. Therefore, the induction-based refixation concept shows potential as a less invasive alternative to conventional revision surgery but requires further validation in more clinically relevant in vitro models.Keywords
Funding Information
- Medizinische Hochschule Hannover (MHH)
This publication has 33 references indexed in Scilit:
- Diagnosis and Detection of Subtle Aseptic Loosening in Total Hip ArthroplastyThe Journal of Arthroplasty, 2022
- Collarless Taper Slip and Collared Composite Beam Stems Differ in Failure Modes and Reoperation RatesThe Journal of Arthroplasty, 2022
- Surgical Technique of a Cement-On-Cement Removal System for Hip and Knee Arthroplasty Revision SurgeryArthroplasty Today, 2021
- On stabilization of loosened hip stems via cement injection into osteolytic cavitiesClinical Biomechanics, 2012
- Effect of cementing technique and cement type on thermal necrosis in hip resurfacing arthroplasty—a numerical studyJournal of Orthopaedic Research, 2011
- Mixed-mode failure strength of implant–cement interface specimens with varying surface roughnessJournal of Biomechanics, 2011
- Influence of femoral stem surface finish on the apparent static shear strength at the stem–cement interfaceJournal of the Mechanical Behavior of Biomedical Materials, 2008
- Cement-in-cement revision hip arthroplasty: an analysis of clinical and biomechanical literatureArchives of orthopaedic and trauma surgery, 2007
- Shear Properties of Bilaminar Polymethylmethacrylate Cement Mantles in Revision Hip Joint ArthroplastyThe Journal of Arthroplasty, 2007
- High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplastyInternational Orthopaedics, 2006