Eike Jakubowitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eike Jakubowitz has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Henning Windhagen
Department of Orthopedic Surgery, Laboratory for Biomechanics and Biomaterials (LBB), Hannover Medical School, Anna-von-Borries-Strasse 1-7, 30625, Hannover, Germany
7 shared publicationsChristof Hurschler
Hannover Medical School, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Anna von Borries Str. 1-7, 30625 Hannover, Germany
6 shared publicationsAnn-Kathrin Einfeldt
Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany
4 shared publicationsAlina Obermeier
Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany
3 shared publicationsMagnus Reulbach
Department of Orthopedic Surgery, Laboratory for Biomechanics and Biomaterials (LBB), Hannover Medical School, Anna-von-Borries-Strasse 1-7, 30625, Hannover, Germany
3 shared publications- Alexander Derksen
Department of Orthopaedic Surgery, Hannover Medical School, Diakovere Annastift, Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 26 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Exploratory in vitro study of inductive heating–assisted refixation in cemented hip stems
To avoid highly invasive cement extraction during revision of cemented hip stems, we investigated in vitro a concept for refixation of loosened cemented stems using induction heating. The thermoplastic polymeric bone cement is softened by heating the metallic stem above the cement’s glass transition temperature, possibly allowing refixation. In an exploratory study three simplified conical Co28Cr6Mo samples were corundum blasted to simulate the surface roughness of matt cemented stems. Three fixation states were produced by cementing the stem samples within a PMMA cavity: (1) initially implanted stem after cement polymerization; (2) loosened stem retained by taper self-locking; (3) refixated stem. The latter should be achieved by inductive surface heating to 95 °C and applying an axial force of 2 kN. Fixation quality was assessed from relative motions in the stem-cement interface, acoustic emissions during quasistatic torsional loading (7 Nm and 10 Nm), and axial pull-out forces of the stem from the cement mantle. Initial fixation yielded a pull-out force of F PO = 1.99 kN ± 0.26 kN, decreasing to 0.84 kN ± 0.38 kN after loosening. After refixation, pull-out forces reached 0.89 kN ± 0.50 kN. However, in one of the three samples, the pull-out force could be restored by refixation. Therefore, the induction-based refixation concept shows potential as a less invasive alternative to conventional revision surgery but requires further validation in more clinically relevant in vitro models.
- 26 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessExploratory in vitro study of inductive heating–assisted refixation in cemented hip stems
To avoid highly invasive cement extraction during revision of cemented hip stems, we investigated in vitro a concept for refixation of loosened cemented stems using induction heating. The thermoplastic polymeric bone cement is softened by heating the metallic stem above the cement’s glass transition temperature, possibly allowing refixation. In an exploratory study three simplified conical Co28Cr6Mo samples were corundum blasted to simulate the surface roughness of matt cemented stems. Three fixation states were produced by cementing the stem samples within a PMMA cavity: (1) initially implanted stem after cement polymerization; (2) loosened stem retained by taper self-locking; (3) refixated stem. The latter should be achieved by inductive surface heating to 95 °C and applying an axial force of 2 kN. Fixation quality was assessed from relative motions in the stem-cement interface, acoustic emissions during quasistatic torsional loading (7 Nm and 10 Nm), and axial pull-out forces of the stem from the cement mantle. Initial fixation yielded a pull-out force of F PO = 1.99 kN ± 0.26 kN, decreasing to 0.84 kN ± 0.38 kN after loosening. After refixation, pull-out forces reached 0.89 kN ± 0.50 kN. However, in one of the three samples, the pull-out force could be restored by refixation. Therefore, the induction-based refixation concept shows potential as a less invasive alternative to conventional revision surgery but requires further validation in more clinically relevant in vitro models.
- Open Access
- 14 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Six-degree-of-freedom knee motion during treadmill walking in mechanically and kinematically aligned TKA
The current literature remains inconclusive about whether kinematic alignment (KA) is superior to mechanical alignment (MA) in total knee arthroplasty (TKA). Therefore, this randomized controlled trial sought to provide further clarification. 39 MA patients, 33 KA patients, and 9 healthy controls were included. All participants underwent three-dimensional gait analysis on a treadmill one day before surgery and one year postoperatively. A preoperative range of motion (ROM) score was calculated and correlated with the postoperative Forgotten Joint Score (FJS). One year after surgery, no significant kinematic differences were observed between MA and KA. However, in Coronal Plane Alignment of the Knee (CPAK) type 1 patients, KA knees more closely reproduced the gait of healthy controls and showed higher walking speed. Correlation analysis revealed that patients with a higher preoperative ROM achieved better outcomes with KA, whereas female patients with lower ROM benefit more from MA. Although no kinematic differences were detected, the strong trend toward reduced joint space in MA compared to KA in CPAK type 1 patients may result from subtle deviations in joint-line restoration or postoperative soft-tissue tension. Both factors can affect load distribution and joint perception. The present findings support a patient-specific approach to alignment selection in TKA.
- 14 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessSix-degree-of-freedom knee motion during treadmill walking in mechanically and kinematically aligned TKA
The current literature remains inconclusive about whether kinematic alignment (KA) is superior to mechanical alignment (MA) in total knee arthroplasty (TKA). Therefore, this randomized controlled trial sought to provide further clarification. 39 MA patients, 33 KA patients, and 9 healthy controls were included. All participants underwent three-dimensional gait analysis on a treadmill one day before surgery and one year postoperatively. A preoperative range of motion (ROM) score was calculated and correlated with the postoperative Forgotten Joint Score (FJS). One year after surgery, no significant kinematic differences were observed between MA and KA. However, in Coronal Plane Alignment of the Knee (CPAK) type 1 patients, KA knees more closely reproduced the gait of healthy controls and showed higher walking speed. Correlation analysis revealed that patients with a higher preoperative ROM achieved better outcomes with KA, whereas female patients with lower ROM benefit more from MA. Although no kinematic differences were detected, the strong trend toward reduced joint space in MA compared to KA in CPAK type 1 patients may result from subtle deviations in joint-line restoration or postoperative soft-tissue tension. Both factors can affect load distribution and joint perception. The present findings support a patient-specific approach to alignment selection in TKA.
- Open Access
- 31 January 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 134, 106775
Predicting gait kinetics using 3-degrees of freedom acceleration data and artificial neural networks
- 31 January 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 134, 106775
Open AccessPredicting gait kinetics using 3-degrees of freedom acceleration data and artificial neural networks
- Open Access
- 13 December 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (1) , e70107
Load Management After Gluteal Tendon Repair: A Controlled Laboratory Study
Tendon lesions of the gluteus medius muscle require surgical repair if conservative treatment fails. Postoperatively, the success of the therapy is influenced by the loading conditions during follow‐up treatment. Excessive loading of the hip joint during walking after surgery – and consequently, potential overload of the repaired gluteal tendon – could jeopardize the success of the therapy. In this controlled laboratory study, six subjects performed an instrumented 3D gait analysis using optoelectronic motion capture under three different loading conditions: full weight‐bearing, partial weight‐bearing, and full unloading with crutches. Gait data were used in silico in an inverse dynamics multi‐body simulation to calculate tendon loading. Peak loads occurred on the gluteal tendons and the hip joint during the stance phase. The force on the gluteus medius tendon during full weight‐bearing amounted to F me = 12.0 ( ± 1.5) N/kg BW, while the force on the gluteus minimus tendon was F mi = 5.0 ( ± 1.6) N/kg BW. Partial weight‐bearing reduced these loads by ≈ 68%, whereas full unloading led to a ≈ 88% reduction compared to full weight‐bearing. In the hip joint, the average maximum load during full weight‐bearing reached F H = 39.8 ( ± 6.7) N/kg BW. To prevent muscle atrophy after gluteal tendon repair, the highest possible load should be applied without compromising suture integrity. Full unloading should be implemented if the tendon and/or bone integrity is compromised and suture stability is reduced. However, if stability is sufficient, partial weight‐bearing is recommended.
- 13 December 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (1) , e70107
Open AccessLoad Management After Gluteal Tendon Repair: A Controlled Laboratory Study
Tendon lesions of the gluteus medius muscle require surgical repair if conservative treatment fails. Postoperatively, the success of the therapy is influenced by the loading conditions during follow‐up treatment. Excessive loading of the hip joint during walking after surgery – and consequently, potential overload of the repaired gluteal tendon – could jeopardize the success of the therapy. In this controlled laboratory study, six subjects performed an instrumented 3D gait analysis using optoelectronic motion capture under three different loading conditions: full weight‐bearing, partial weight‐bearing, and full unloading with crutches. Gait data were used in silico in an inverse dynamics multi‐body simulation to calculate tendon loading. Peak loads occurred on the gluteal tendons and the hip joint during the stance phase. The force on the gluteus medius tendon during full weight‐bearing amounted to F me = 12.0 ( ± 1.5) N/kg BW, while the force on the gluteus minimus tendon was F mi = 5.0 ( ± 1.6) N/kg BW. Partial weight‐bearing reduced these loads by ≈ 68%, whereas full unloading led to a ≈ 88% reduction compared to full weight‐bearing. In the hip joint, the average maximum load during full weight‐bearing reached F H = 39.8 ( ± 6.7) N/kg BW. To prevent muscle atrophy after gluteal tendon repair, the highest possible load should be applied without compromising suture integrity. Full unloading should be implemented if the tendon and/or bone integrity is compromised and suture stability is reduced. However, if stability is sufficient, partial weight‐bearing is recommended.
- Open Access
- 16 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 984
The Influence of Reaming Velocity During Preparation of the Femoral Canal—An In Vitro Analysis of Two Straight Femoral Revision Stems with a Fluted Tapered Design
Background: The use of tapered fluted revision stems has been shown to be reliable and safe. Primary stability is mandatory for a long-lasting fixation between bone and a prosthesis. Nevertheless, aseptic loosening due to insufficient primary stability occurs and may be related to technically improper preparation of the femoral canal. Instructions of manufacturers are heterogeneous regarding preparation of implant beds. Questions/Purposes: Does speed or the design of the reamer influence the accuracy of the implant bed and, consecutively, primary stability? Materials and Methods: A test foam with an elastic moduli and pressure resistance similar to that of cancellous bone was used. The medullary canal was prepared with the use of reamers of two different straight and tapered femoral revision devices. Three different rotational speeds were used for preparation. After preparation, primary stability was measured and fixating characteristics were derived. Results: Sufficient primary stability was achievable by all three preparation methods but fixating characteristics were different. Significantly higher micro-motions were detected near the tip of the prosthesis compared to those at all more proximal measuring points. Reaming with high velocity resulted in significantly higher micro-motions compared to that with mid- or low-speed burring. Conclusions: Different preparation methods may be one explanation for the range of reported survivorship data of the two devices with aseptic loosening as the end point. The precision of the implant bed and fixating characteristics were best after reaming with lower velocity. Superior but not significantly better fixation characteristics were achieved with the monobloc stem compared to those with the modular device.
- 16 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 984
Open AccessThe Influence of Reaming Velocity During Preparation of the Femoral Canal—An In Vitro Analysis of Two Straight Femoral Revision Stems with a Fluted Tapered Design
Background: The use of tapered fluted revision stems has been shown to be reliable and safe. Primary stability is mandatory for a long-lasting fixation between bone and a prosthesis. Nevertheless, aseptic loosening due to insufficient primary stability occurs and may be related to technically improper preparation of the femoral canal. Instructions of manufacturers are heterogeneous regarding preparation of implant beds. Questions/Purposes: Does speed or the design of the reamer influence the accuracy of the implant bed and, consecutively, primary stability? Materials and Methods: A test foam with an elastic moduli and pressure resistance similar to that of cancellous bone was used. The medullary canal was prepared with the use of reamers of two different straight and tapered femoral revision devices. Three different rotational speeds were used for preparation. After preparation, primary stability was measured and fixating characteristics were derived. Results: Sufficient primary stability was achievable by all three preparation methods but fixating characteristics were different. Significantly higher micro-motions were detected near the tip of the prosthesis compared to those at all more proximal measuring points. Reaming with high velocity resulted in significantly higher micro-motions compared to that with mid- or low-speed burring. Conclusions: Different preparation methods may be one explanation for the range of reported survivorship data of the two devices with aseptic loosening as the end point. The precision of the implant bed and fixating characteristics were best after reaming with lower velocity. Superior but not significantly better fixation characteristics were achieved with the monobloc stem compared to those with the modular device.
- Open Access
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2140
Gait Characteristics of People with Hallux and Forefoot Amputations—A Case Series
Background/Objectives: Minor amputations are increasingly relevant due to a growing proportion of lower limb amputations but remain underrepresented in research. These amputations impair mobility due to altered gait, and biomimetic devices could potentially address this issue. Fundamental research is needed to better understand this pathological gait pattern. The aim of this study is to analyse the holistic gait characteristics of the lower extremity during barefoot walking in individuals with different levels of minor amputations for the first time. Methods: Eight young to middle-aged subjects with minor foot amputations (four × hallux; four × forefoot) underwent instrumented gait analysis. Kinematic and kinetic data were acquired barefoot at self-selected gait speeds. Individual gait characteristics were considered relative to the physiological gait represented by the 95% confidence interval of ten unimpaired volunteers. Results: Subjects with a minor amputation show reduced walking speed and shorter stride length compared to controls. Sagittal ankle moment and ankle power are lower, with greater deficits in subjects with a forefoot amputation. Proximal joints also show variability, notably reduced knee flexion in subjects with a forefoot amputation and a more flexed hip profile in six subjects. Single-subject frontal plane kinetics also vary. Conclusions: Although the subjects with a hallux amputation exhibit smaller deviations in ankle kinetics than the subjects with a forefoot amputation, proximal joint abnormalities are present across cases. These findings highlight the need for a broad range of care to adequately address individual needs.
- 21 March 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (7) , 2140
Open AccessGait Characteristics of People with Hallux and Forefoot Amputations—A Case Series
Background/Objectives: Minor amputations are increasingly relevant due to a growing proportion of lower limb amputations but remain underrepresented in research. These amputations impair mobility due to altered gait, and biomimetic devices could potentially address this issue. Fundamental research is needed to better understand this pathological gait pattern. The aim of this study is to analyse the holistic gait characteristics of the lower extremity during barefoot walking in individuals with different levels of minor amputations for the first time. Methods: Eight young to middle-aged subjects with minor foot amputations (four × hallux; four × forefoot) underwent instrumented gait analysis. Kinematic and kinetic data were acquired barefoot at self-selected gait speeds. Individual gait characteristics were considered relative to the physiological gait represented by the 95% confidence interval of ten unimpaired volunteers. Results: Subjects with a minor amputation show reduced walking speed and shorter stride length compared to controls. Sagittal ankle moment and ankle power are lower, with greater deficits in subjects with a forefoot amputation. Proximal joints also show variability, notably reduced knee flexion in subjects with a forefoot amputation and a more flexed hip profile in six subjects. Single-subject frontal plane kinetics also vary. Conclusions: Although the subjects with a hallux amputation exhibit smaller deviations in ankle kinetics than the subjects with a forefoot amputation, proximal joint abnormalities are present across cases. These findings highlight the need for a broad range of care to adequately address individual needs.
- 4 March 2025
- Published by Springer Nature in Die Unfallchirurgie
- Vol. 128 (4) , 270-277
Bewegungsanalyse in der orthopädietechnischen Forschung
Zusammenfassung Die instrumentierte Bewegungsanalyse spielt eine zentrale Rolle in der Orthopädietechnik und bietet einzigartige Möglichkeiten, biomechanische, muskuloskeletale und neurologische Prozesse zu analysieren und gezielt zu optimieren. Der Beitrag beleuchtet mehrere aktuelle Studien, die unter dem Einsatz der Bewegungsanalyse verschiedene Aspekte in den Bereichen der Prothesenentwicklung, -steuerung, -belastung und -sicherheit untersuchen. Die vorliegende Zusammenstellung verdeutlicht das mittlerweile essenzielle Potenzial der instrumentierten Bewegungsanalyse in der exoskeletalen Prothetik. Sie trägt nicht mehr nur allein nachhaltig zur Steigerung der Lebensqualität von Prothesennutzern bei, sondern ist mittlerweile unverzichtbar für die Funktionalität und Sicherheit aktueller und zukünftiger orthopädietechnischer Hilfsmittel.
- 4 March 2025
- Published by Springer Nature in Die Unfallchirurgie
- Vol. 128 (4) , 270-277
Bewegungsanalyse in der orthopädietechnischen Forschung
Zusammenfassung Die instrumentierte Bewegungsanalyse spielt eine zentrale Rolle in der Orthopädietechnik und bietet einzigartige Möglichkeiten, biomechanische, muskuloskeletale und neurologische Prozesse zu analysieren und gezielt zu optimieren. Der Beitrag beleuchtet mehrere aktuelle Studien, die unter dem Einsatz der Bewegungsanalyse verschiedene Aspekte in den Bereichen der Prothesenentwicklung, -steuerung, -belastung und -sicherheit untersuchen. Die vorliegende Zusammenstellung verdeutlicht das mittlerweile essenzielle Potenzial der instrumentierten Bewegungsanalyse in der exoskeletalen Prothetik. Sie trägt nicht mehr nur allein nachhaltig zur Steigerung der Lebensqualität von Prothesennutzern bei, sondern ist mittlerweile unverzichtbar für die Funktionalität und Sicherheit aktueller und zukünftiger orthopädietechnischer Hilfsmittel.
- Open Access
- 23 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 164, 106905
Soft tissue-like coupling materials for in vitro acoustic emission studies in total hip arthroplasty
- 23 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 164, 106905
Open AccessSoft tissue-like coupling materials for in vitro acoustic emission studies in total hip arthroplasty
- Open Access
- 26 November 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 134 (1) , 104266
Hearing the unheard: Fundamentals of acoustic emission signals as predictors of total hip arthroplasty implant loosening
Implant loosening remains a primary cause of failure of total hip arthroplasty1 (THA) and is often detected late, when pain occurs. Acoustic emission2 (AE) analysis is a promising method for early loosening detection, on the supposition that relative movements at the bone-implant interface induce detectable AE signals. To distinguish loosening-induced AE signals from those of stable THA components in vitro investigations are necessary. Substituting human with animal bone for such testing could enable simplified and cost-effective sample preparation. The aim of this study was to investigate whether AE signals differ between bone tissues of different species. AE signals generated by relative movements between TiAl6V4 and human, bovine, and porcine cortical bone were investigated. Per species, 125 movements were analyzed, with 26 AE features identified for each movement. The most important time and frequency features of AE signals from human bone differed significantly from those of both animal species. Signals of human origin were longer and exhibited higher rise time. The main frequency components of human AE signals were in a lower frequency range, with a centroid frequency of 113.7 kHz. Based on these differences, it is not advisable to replace human cortical bone with animal bone for AE-related in vitro studies.
- 26 November 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 134 (1) , 104266
Open AccessHearing the unheard: Fundamentals of acoustic emission signals as predictors of total hip arthroplasty implant loosening
Implant loosening remains a primary cause of failure of total hip arthroplasty1 (THA) and is often detected late, when pain occurs. Acoustic emission2 (AE) analysis is a promising method for early loosening detection, on the supposition that relative movements at the bone-implant interface induce detectable AE signals. To distinguish loosening-induced AE signals from those of stable THA components in vitro investigations are necessary. Substituting human with animal bone for such testing could enable simplified and cost-effective sample preparation. The aim of this study was to investigate whether AE signals differ between bone tissues of different species. AE signals generated by relative movements between TiAl6V4 and human, bovine, and porcine cortical bone were investigated. Per species, 125 movements were analyzed, with 26 AE features identified for each movement. The most important time and frequency features of AE signals from human bone differed significantly from those of both animal species. Signals of human origin were longer and exhibited higher rise time. The main frequency components of human AE signals were in a lower frequency range, with a centroid frequency of 113.7 kHz. Based on these differences, it is not advisable to replace human cortical bone with animal bone for AE-related in vitro studies.
- Open Access
- 5 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
A new method called MiKneeSoTA to minimize knee soft-tissue artifacts in kinematic analysis
The use of marker-based optical motion capture to estimate joint kinematics during gait is currently limited by errors associated with soft-tissue-induced motion artefacts (STIMA) and ambiguity in landmark palpation. This study therefore presents a novel protocol aiming to Minimize Knee Soft-Tissue Artefacts (MiKneeSoTA) and their effect on kinematic estimates. Relying on an augmented marker set and a new inverse kinematics approach, our method leverages frame-by-frame optimization to adjust best-fit cylinders that have been automatically generated based on the relative position of lower limb markers during an initial static trial. Tibiofemoral rotations and translations are then calculated along the anatomical joint axes based on the relative 3D motion of these cylinders. When compared against the conventional Helen-Hayes approach, in vivo assessment of fifteen healthy subjects revealed the MiKneeSoTA approach led to kinematic profiles with significantly lower standard deviations in joint rotations across trials, and even visibly reduced the presence of high frequency fluctuations presumably associated with e.g. soft-tissue vibration. In addition to agreeing with previously published bone pin and fluoroscopy datasets, our results illustrate MiKneeSoTA’s ability to abate the effect of STIMA induced by lateral knee ligaments. Our findings indicate that MiKneeSoTA is in fact a promising approach to mitigate knee joint STIMA and thus enable the previously unattainable accurate estimation of translational knee joint motion with an optoelectronic system.
- 5 September 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessA new method called MiKneeSoTA to minimize knee soft-tissue artifacts in kinematic analysis
The use of marker-based optical motion capture to estimate joint kinematics during gait is currently limited by errors associated with soft-tissue-induced motion artefacts (STIMA) and ambiguity in landmark palpation. This study therefore presents a novel protocol aiming to Minimize Knee Soft-Tissue Artefacts (MiKneeSoTA) and their effect on kinematic estimates. Relying on an augmented marker set and a new inverse kinematics approach, our method leverages frame-by-frame optimization to adjust best-fit cylinders that have been automatically generated based on the relative position of lower limb markers during an initial static trial. Tibiofemoral rotations and translations are then calculated along the anatomical joint axes based on the relative 3D motion of these cylinders. When compared against the conventional Helen-Hayes approach, in vivo assessment of fifteen healthy subjects revealed the MiKneeSoTA approach led to kinematic profiles with significantly lower standard deviations in joint rotations across trials, and even visibly reduced the presence of high frequency fluctuations presumably associated with e.g. soft-tissue vibration. In addition to agreeing with previously published bone pin and fluoroscopy datasets, our results illustrate MiKneeSoTA’s ability to abate the effect of STIMA induced by lateral knee ligaments. Our findings indicate that MiKneeSoTA is in fact a promising approach to mitigate knee joint STIMA and thus enable the previously unattainable accurate estimation of translational knee joint motion with an optoelectronic system.