Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation
Open Access
- 24 October 2021
- journal article
- research article
- Published by Springer Nature in Eye and Vision
- Vol. 8 (1) , 1-8
Abstract
Purpose: To dynamically assess variations in pupil diameter induced by changes in brightness in myopic eyes implanted with an implantable collamer lens (ICL, STAAR Surgical) with a central port. Methods: This prospective, observational single-center case series study comprised 65 eyes from 65 consecutive patients undergoing ICL implant. A modified commercially available swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) device was used for imaging and performing dynamic pupillometry under changing light conditions before and after a mean follow-up interval of four months after surgery. Results: Preoperative mean pupil size under photopic conditions was 3.38 ± 0.64 mm; after surgery, this increased to 3.48 ± 0.61 mm. Mean pupil size under scotopic light conditions was 5.72 ± 0.79 mm before surgery and 5.84 ± 0.77 mm postoperatively. The differences between preoperative and postoperative pupil diameter in miosis and mydriasis were 0.10 ± 0.44 mm (P = 0.078) and 0.12 ± 0.58 mm (P = 0.098), respectively. The scotopic pupil exceeded the optic zone of the implanted lens in 39 eyes (60%). The mean central vault value was 412 ± 177 μm under maximum miosis and 506 ± 190 μm under maximum mydriasis. We found a positive correlation between vault and differences in pupil diameter under all light conditions (P < 0.05). Conclusion: Dynamic AS-OCT enables a very precise determination of the pupillary diameter in the iris plane. The changes in the pupil diameter under different light conditions after the implantation of an ICL are related to the postoperative vault.Keywords
This publication has 22 references indexed in Scilit:
- Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic AstigmatismMedicine, 2016
- Pupil Diameter Changes in High Myopes after Collamer Lens ImplantationOptometry and Vision Science, 2015
- Ghost-image analysis in phakic intraocular lenses with central hole as a potential cause of dysphotopsiaJournal of Cataract & Refractive Surgery, 2015
- Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatismJournal of Cataract & Refractive Surgery, 2015
- Risk Factors Associated With Night Vision Disturbances After Phakic Intraocular Lens ImplantationAmerican Journal of Ophthalmology, 2014
- Evaluation of pupil diameter after posterior chamber phakic intraocular lens implantationEye, 2009
- Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2006
- Pupil diameter changes and reaction after posterior chamber phakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2002
- Colvard Pupillometer Measurement of Scotopic Pupil Diameter in Emmetropes and MyopesJapanese Journal of Ophthalmology, 2002
- Blendempfindlichkeit und Halos nach "phakic IOL"-Operation zur Behandlung einer hohen MyopieDer Ophthalmologe, 2001