Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation
Authors:
- Yeoun Sook ChunYCYeoun Sook Chun
- In Ki ParkIPIn Ki Park
- Hyeon Il LeeHLHyeon Il Lee
- Jong Ho LeeJLJong Ho Lee
- Jae Chan KimJKJae Chan Kim
- 1 September 2006
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 32 (9) , 1452-1458
Abstract
To evaluate the changes in laser iridotomies, intraocular pressure (IOP), angle structures, and pupil diameter after implantable contact lens (ICL) (Version 4 Staar Surgical) implantation in myopic Asian eyes. Department of Ophthalmology, Chung-Ang University Yongsan Hospital, Seoul, Korea. The ICL was implanted in 81 eyes of 43 patients with spherical equivalent greater than -6.00 diopters. Gonioscopy examination was performed 1 day after laser iridotomy and 6 and 12 months after ICL implantation. The changes in laser iridotomy sites, IOP, and pupil diameter were also evaluated. Ten eyes (12.3%) had occlusion or narrowing of the laser iridotomy sites. The angle width was more than 30 degrees in all cases preoperatively but narrowed to less than 20 degrees in 16 eyes (19.8%) 6 months postoperatively. The mean pigment, measured by the semiquantitative method (grade 0 to 4), was 2.03 in the inferior angle, 0.18 in the nasal angle, 0.12 in the temporal angle, and 0.00 in the superior angle 12 months postoperatively. The pigment in all quadrants increased temporally as a result of the laser iridotomy or iris rubbing by the ICL; however, the pigments absorbed gradually and decreased to values before laser iridotomy 12 months postoperatively. There was a temporary increase in IOP from the instillation of steroid eyedrops 1 week and 1 month postoperatively; IOP returned to the preoperative level and remained there 12 months postoperatively. There was a significant decrease in pupil diameter 1 and 3 months postoperatively; the diameter returned to the preoperative size at 6 and 12 months. Pigment dispersion syndrome and pigmentary glaucoma were not seen. Implantation of the ICL narrowed the angle width but did not increase trabecular pigmentation compared with values after laser iridotomy, indicating ICL implantation is safe regardless of the pigmentary changes in the trabecular meshwork.Keywords
This publication has 21 references indexed in Scilit:
- Position of angle-supported, iris-fixated, and ciliary sulcus–implanted myopic phakic intraocular lenses evaluated by Scheimpflug photographyAmerican Journal of Ophthalmology, 2004
- Pupillary block glaucoma secondary to posterior chamber phakic intraocular lens implantation for high myopiaJournal of Cataract & Refractive Surgery, 2004
- Ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for myopiaJournal of Cataract & Refractive Surgery, 2003
- Implantable contact lens for moderate to high myopiaJournal of Cataract & Refractive Surgery, 2003
- U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopiaOphthalmology, 2003
- Collamer intraocular contact lens to correct high myopiaJournal of Cataract & Refractive Surgery, 1996
- Effectiveness of intraocular lens calculation in high ametropiaJournal of Cataract & Refractive Surgery, 1989
- Pigment dispersion syndrome: a clinical study.British Journal of Ophthalmology, 1981
- Pigmentary dispersion.British Journal of Ophthalmology, 1981
- Pigmentary Dispersion and GlaucomaArchives of Ophthalmology (1950), 1979