Steady‐state functional MRI using spoiled small‐tip fast recovery imaging
- 11 March 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 536-543
Abstract
Purpose: To determine whether a recently proposed steady‐state magnetic resonance imaging (MRI) sequence, “small‐tip fast recovery” (STFR), can be used for functional brain imaging. Compared to existing functional MRI (fMRI) based on ‐contrast and long echo time, STFR has the potential for high‐resolution imaging with reduced B0 artifacts such as geometric distortions, blurring, or local signal dropout.Methods: We used Monte Carlo Bloch simulations to calculate the voxel‐averaged steady‐state signal during rest and activation, for blood oxygen level dependent (BOLD) and STFR. STFR relies on a tailored “tip‐up” radiofrequency pulse to align the spins with the longitudinal axis after each data readout segment, and here we performed proof‐of‐concept in vivo STFR fMRI experiments using a tip‐up pulse tailored to a two‐dimensional region‐of‐interest in motor cortex. Experiments were performed on multiple subjects to test reliability of the functional activation maps.Results: Bloch simulations predict a detectable functional signal that depends mainly on intravoxel dephasing, and only weakly on spin diffusion. STFR produces similar activation maps and signal change as BOLD in finger‐tapping experiments, and shows reliability comparable to BOLD.Conclusion: STFR can produce functional contrast (even with short TE), and is a potential alternative to long‐TE ( ) fMRI. The functional contrast arises primarily from the interaction between ‐like dephasing and the tailored tip‐up pulse, and not from spin diffusion. Magn Reson Med 73:536–543, 2015. © 2014 Wiley Periodicals, Inc.Keywords
Funding Information
- National Institutes of Health (R21EB012674, R01NS058576)
This publication has 26 references indexed in Scilit:
- Small‐tip fast recovery imaging using non‐slice‐selective tailored tip‐up pulses and radiofrequency‐spoilingMagnetic Resonance in Medicine, 2012
- Analysis of the BOLD characteristics in pass‐band bSSFP fMRIInternational Journal of Imaging Systems and Technology, 2012
- Layer‐specific functional and anatomical MRI of the retina with passband balanced SSFPMagnetic Resonance in Medicine, 2011
- Modeling SSFP functional MRI contrast in the brainMagnetic Resonance in Medicine, 2008
- Full‐brain coverage and high‐resolution imaging capabilities of passband b‐SSFP fMRI at 3TMagnetic Resonance in Medicine, 2008
- Modelling vascular reactivity to investigate the basis of the relationship between cerebral blood volume and flow under CO2 manipulationNeuroImage, 2008
- Signal and noise characteristics of SSFP FMRI: A comparison with GRE at multiple field strengthsNeuroImage, 2007
- Systematic investigation of balanced steady‐state free precession for functional MRI in the human visual cortex at 3 TeslaMagnetic Resonance in Medicine, 2006
- Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging.Proceedings of the National Academy of Sciences, 1992
- Spoiling of transverse magnetization in steady‐state sequencesMagnetic Resonance in Medicine, 1991