Diagnosis-to-ablation time as a predictor of success: early choice for pulmonary vein isolation and long-term outcome in atrial fibrillation: results from the Middelheim-PVI Registry
Authors:
- 2 March 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (4) , 589-595
Abstract
The aim of the study is to define long-term outcome of pulmonary vein isolation (PVI) in atrial fibrillation (AF) and to determine whether time window between AF diagnosis and PVI affects outcome. Consecutive AF patients undergoing PVI (2006–14) were followed for 5 years. Primary outcome was clinical success, defined as freedom of documented AF without anti-arrhythmic drugs respecting a 1-month blanking period. A 1000 patients were included (age 60 ± 10 years, CHA2DS2-VASc score 1 ± 1). The cohort was divided in four quartiles (Q) according to the diagnosis-to-ablation time (DAT): Q1 DAT 0–11 months (N = 244), Q2 DAT 12–≤33 months (N = 254), Q3 DAT 34-≤70 months (N = 252) and Q4 DAT 71–360 months (N = 250). Mean follow-up was 44.3±21.0 months. At 5 years, clinical success was achieved in 45.2 ± 2.0% of patients. Independent predictors of clinical success were AF type (HR = 0.61; 95%CI 0.50–0.74; P < 0.0001), left atrial size (HR = 1.03; 95%CI 1.02–1.05; P < 0.0001), DAT (HR = 1.00; 95%CI 1.00–1.00; P = 0.001), ablation technique (P = 0.012), and year of ablation (HR = 0.93; 95%CI 0.86–1.00; P = 0.045) in multivariable-adjusted analysis. The highest clinical success was achieved when PVI was performed within the first year, and gradually declined with increasing DAT: 55.9 ± 4.6% for Q1, 46.9 ± 4.0% for Q2, 45.5 ± 3.6% for Q3, and 35.5 ± 3.6% for Q4 (P < 0.001). Long-term success rate of PVI is 45.2 ± 2.0%. Shorter diagnosis-to-ablation times are associated with better clinical success. Our data advocate for early PVI following diagnosis of AF.Keywords
This publication has 20 references indexed in Scilit:
- Impact of Radiofrequency Characteristics on Acute Pulmonary Vein Reconnection and Clinical Outcome After PVAC AblationJournal of Cardiovascular Electrophysiology, 2012
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEP Europace, 2012
- An Apparent Way of Achieving Proof of Pulmonary Vein Disconnection during Cryoballoon AblationPacing and Clinical Electrophysiology, 2011
- The magnetic navigation system allows safety and high efficacy for ablation of arrhythmiasEP Europace, 2011
- Guidelines for the management of atrial fibrillationEP Europace, 2010
- Pulmonary vein isolation with the 30 and 35 mm high-density mesh ablatorEP Europace, 2010
- Triggering Pulmonary Veins: A Paradoxical Predictor for Atrial Fibrillation Recurrence After PV IsolationJournal of Cardiovascular Electrophysiology, 2010
- Progression From Paroxysmal to Persistent Atrial FibrillationJACC, 2010
- Treatment of Atrial Fibrillation With Antiarrhythmic Drugs or Radiofrequency AblationCirculation: Arrhythmia and Electrophysiology, 2009
- Electrical, contractile and structural remodeling during atrial fibrillationCardiovascular Research, 2002