The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?
Authors:
- 23 February 2018
- journal article
- review article
- Published by Springer Nature in Journal of Echocardiography
- Vol. 16 (3) , 130-138
Abstract
Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.Keywords
This publication has 28 references indexed in Scilit:
- Comparison of Left Ventricular Outflow Geometry and Aortic Valve Area in Patients With Aortic Stenosis by 2-Dimensional Versus 3-Dimensional EchocardiographyThe American Journal of Cardiology, 2012
- Integration of 3D Imaging Data in the Assessment of Aortic StenosisCirculation: Cardiovascular Imaging, 2011
- Comparison between cardiovascular magnetic resonance and transthoracic doppler echocardiography for the estimation of effective orifice area in aortic stenosisJournal of Cardiovascular Magnetic Resonance, 2011
- Validation of Conventional and Simplified Methods to Calculate Projected Valve Area at Normal Flow Rate in Patients With Low Flow, Low Gradient Aortic Stenosis: The Multicenter TOPAS (True or Pseudo Severe Aortic Stenosis) StudyJournal of the American Society of Echocardiography, 2010
- Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve stenosisInternational Journal of Cardiology, 2009
- Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CTThe International Journal of Cardiovascular Imaging, 2008
- Assessment of Left Ventricular Outflow Tract Geometry in Non-Stenotic and Stenotic Aortic Valves by Cardiovascular Magnetic ResonanceJournal of Cardiovascular Magnetic Resonance, 2006
- Low-Gradient Aortic StenosisCirculation, 2003
- Continuity equation and Gorlin formula compared with directly observed orifice area in native and prosthetic aortic valves.Heart, 1992
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IAmerican Heart Journal, 1951