Ebraham Alskaf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ebraham Alskaf has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Attila Kardos
Milton Keynes University Hospital, Standing Way, Eaglestone, Milton Keynes, UK
1 shared publication
Latest Publications
- 23 February 2018
- Published by Springer Nature in Journal of Echocardiography
- Vol. 16 (3) , 130-138
The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?
Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.
- 23 February 2018
- Published by Springer Nature in Journal of Echocardiography
- Vol. 16 (3) , 130-138
The mystery of defining aortic valve area: what have we learnt from three-dimensional imaging modalities?
Aortic valve area is one of the main criteria used by echocardiography to determine the degree of valvular aortic stenosis, and it is calculated using the continuity equation which assumes that the flow volume of blood is equal at two points, the aortic valve area and the left ventricular outflow tract (LVOT). The main fallacy of this equation is the assumption that the LVOT area which is used to calculate the flow volume at the LVOT level is circular, where it is often an ellipse and sometimes irregular. The aim of this review is to explain the physiology of the continuity equation, the different sources of errors, the added benefits of using three-dimensional imaging modalities to measure LVOT area, the latest recommendations related to valvular aortic stenosis, and to introduce future perspectives. A literature review of studies comparing aortic valve area and LVOT area, after using three-dimensional data, has shown underestimation of both measurements when using the continuity equation. This has more impact on patients with discordant echocardiographic measurements when aortic valve area is disproportionate to haemodynamic measurements in assessing the degree of aortic stenosis. Although fusion imaging modalities of LVOT area can help in certain group of patients to address the issue of aortic valve area underestimation, further research on introducing a correction factor to the conventional continuity equation might be more rewarding, saving patients additional tests and potential radiation, with no clear evidence of cost-effectiveness.