Accuracy of Glycemic Measurements in the Critically Ill
- 1 June 2008
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 10 (3) , 169-177
Abstract
Background: Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there were differences in blood glucose values measured by whole blood capillary and arterial samples using three different bedside blood glucose meters and a blood gas analyzer as compared to a reference blood glucose analyzer. Methods: Sixty subjects were recruited from a university hospital medical/surgical intensive care unit. Matching capillary and arterial samples were analyzed by a clinical blood glucose reference analyzer (YSI®, Yellow Springs Instrument, Yellow Springs, OH) and three blood glucose meters (Lifescan [Milpitas, CA] SureStepFlexx®, Roche [Indianapolis, IN] Accu-Chek Inform®, and Abbott [Alameda, CA] FreeStyle®). Additionally, the arterial samples were analyzed by a point-of-care blood gas analyzer (Chiron 865®, Bayer, Tarrytown, NY). Results: Data analysis included repeated-measures analysis of variance, Consensus Error Grid analysis, Bland-Altman plots, and numerical estimates of inaccuracy. With capillary samples there were high numbers of errors as compared to the reference instrument. Measurement of blood glucose with arterial samples demonstrates a higher degree of accuracy. With arterial samples, the Abbott FreeStyle blood glucose meter and the blood gas analyzer glucose exhibited the lowest median and mean relative absolute deviation. Conclusion: In critically ill adult patients, measurement of blood glucose using arterial samples is recommended. Using arterial blood, the Abbott FreeStyle blood glucose meter and the point-of-care blood gas analyzer (Bayer Chiron 865) were shown to be highly accurate instruments to measure arterial blood glucose.Keywords
This publication has 14 references indexed in Scilit:
- Intensive Insulin Therapy in the Medical ICUNew England Journal of Medicine, 2006
- Intensive Insulin in Intensive CareNew England Journal of Medicine, 2006
- Reliability of point-of-care testing for glucose measurement in critically ill adults*Critical Care Medicine, 2005
- Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemiaEuropean Journal of Endocrinology, 2005
- Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patientsIntensive Care Medicine, 2004
- Standardization of intravenous insulin therapy improves the efficiency and safety of blood glucose control in critically ill adultsIntensive Care Medicine, 2004
- Association Between Hyperglycemia and Increased Hospital Mortality in a Heterogeneous Population of Critically Ill PatientsMayo Clinic Proceedings, 2003
- Performance Evaluation of Blood Glucose Monitoring DevicesDiabetes Technology & Therapeutics, 2003
- Outcome benefit of intensive insulin therapy in the critically ill: Insulin dose versus glycemic control*Critical Care Medicine, 2003
- Intensive Insulin Therapy in Critically Ill PatientsNew England Journal of Medicine, 2001