Abstract
Reduced switch active phase converters (APC) are cost-effective solutions for running three-phase loads from single-phase grids. This paper proposes a novel auxiliary capacitor based active phase converter (AC-APC) for this application. The combination of the topological location of the auxiliary capacitor and the control of AC-APC reduces current stress on the semiconductor devices. In this work, a selection criterion for the optimal auxiliary capacitor value is formulated to reduce the device currents in such a way that the overall efficiency is enhanced. This paper presents a comparative analysis of converter VA and device power loss for conventional H-bridge active front end and inverter based topology, APC, and AC-APC. To evaluate the efficacy of proposed AC-APC, an experimental study is conducted on APC and AC-APC feeding a 3hp three-phase induction motor. At a full load of 2.5 kW and 0.8pf, measured maximum efficiency of the AC-APC is 2% higher than that of the APC. Analytical evaluation of converter currents and device power loss are in close agreement with experimental observations.
Funding Information
  • Central Power Research Institute
  • Ministry of Power
  • Power Conversion, Control, and Protection Technologies for Microgrid

This publication has 23 references indexed in Scilit: