  • Reduced Rating Active Phase Converter for Three-Phase Induction Generator Based Single Phase Grid-Tied Systems

    by Anil K. Adapa, Vinod John

    The distribution systems and microgrids in remote and rural areas are often of single-phase nature due to economic viability. Fixed frequency three-phase induction generators are popular in such applications due to their competitive performance features and utility. This paper proposes a control approach for injecting power to a single-phase grid from an active phase converter (APC) assisted three-phase IG. The presented approach ensures balanced operation of the IG even with variable generation. This work proposes a method of using an ac auxiliary capacitor that reduces the APC pole currents and improves the converter efficiency. Closed-form expression of the grid current and converter pole currents for a given operating point of the IG are derived. Based on the analysis and the converter current expressions, a procedure to find the optimal auxiliary capacitance for a given operating point of the IG is presented. Experimental results are provided to validate the theoretical framework and APC control approach. The experimental results demonstrate injection of 2.4 kW real power into the single-phase grid at near unity power factor and validate the proposed control of APC - IG system.


  • Eigenvalue Analysis and Behavioural Common-Mode Equivalent Circuit for an Asymmetric Active Phase Converter

    by Anil K. Adapa, Vinod John

    A common-mode (CM) filter for a reduced switch active phase converter (APC) is proposed in this article for mitigation of switching frequency, and higher order CM current (CMC) injected into the grid. Due to asymmetry of the APC topology, a mixed-mode analysis of the differential-mode (DM) and CM components becomes essential. The presented state-space approach for the converter analysis captures the mixed-mode behavior of the APC. The eigenvalue analysis of the system shows that the inclusion of the proposed CM filter does not affect the existing DM APC system poles. Hence, the CM filter does not affect the APC control structure. This work also introduces an equivalent behavioral circuit which simplifies the CM filter component selection. This article provides a design methodology for the selection of the CM filter components by identifying the range of CM resonance frequencies. This design method results in active damping of the CM resonance without any additional control loop. The simulation results validate the behavioral CM equivalent circuit. The experimental validation is carried out on a laboratory APC prototype feeding a three-phase 3 hp induction motor from a single-phase grid. The measured CM voltages and currents validate the efficacy of the proposed CM filter for the APC.


  • Low-Frequency DC-Link Capacitor Current Mitigation in Reduced Switch Count Single-Phase to Three-Phase Converter

    by Anil K. Adapa, Sujata Bhowmick, Vinod John

    This work proposes an approach to mitigate the dc-link double-frequency ripple current in a 3-leg single-phase to three-phase converter. This work is based on an economical Active Phase Converter (APC) utilizing a fewer number of switches. The presented approach does not demand either bulky dc side passive ripple filter or additional semiconductor switches typically employed in active dc-link ripple filters. The proposed method introduces an appropriately selected ac capacitor into the APC circuit, also known as AC-APC, which mitigates the dc-link double-frequency ripple. Reduction of power loss in the Equivalent Series Resistor (ESR) of the dc-bus capacitor associated with the dc-link double-frequency ripple current enhances the lifetime of electrolytic capacitor typically employed in the APC. At full load, the dc-link current at double-fundamental frequency is reduced by more than 50% and the temperature rise in the dc-bus electrolytic capacitors is reduced by more than 30%. The proposed method is validated experimentally using a laboratory prototype APC. Theoretical and simulation results of the dc-link double-frequency current are in close agreement with the experimental findings.


  • An Auxiliary-Capacitor-Based Active Phase Converter With Reduced Device Current Stress

    by Anil K Adapa, Vinod John

    Reduced switch active phase converters (APC) are cost-effective solutions for running three-phase loads from single-phase grids. This paper proposes a novel auxiliary capacitor based active phase converter (AC-APC) for this application. The combination of the topological location of the auxiliary capacitor and the control of AC-APC reduces current stress on the semiconductor devices. In this work, a selection criterion for the optimal auxiliary capacitor value is formulated to reduce the device currents in such a way that the overall efficiency is enhanced. This paper presents a comparative analysis of converter VA and device power loss for conventional H-bridge active front end and inverter based topology, APC, and AC-APC. To evaluate the efficacy of proposed AC-APC, an experimental study is conducted on APC and AC-APC feeding a 3hp three-phase induction motor. At a full load of 2.5 kW and 0.8pf, measured maximum efficiency of the AC-APC is 2% higher than that of the APC. Analytical evaluation of converter currents and device power loss are in close agreement with experimental observations.


  • Active-Phase Converter for Operation of Three-Phase Induction Motors on Single-Phase Grid

    by Anil K. Adapa, Vinod John

    The operation of a three-phase induction machine on single-phase supply has been an approach used for electromechanical energy conversion in rural communities with limited or no access to the three-phase grid. Such single-phase to three-phase conversion can be achieved by passive and active means. In passive methods, fixed capacitors are used for starting and running the motor. Single-phase to three-phase conversion with reduced switch count is desirable, as this leads to a lower cost. However, it is a challenge to start an induction motor using such a power converter and to maintain balanced three-phase voltage under all loading conditions. It is shown in this work that balanced excitation cannot be achieved under all conditions with variable capacitor emulation method. An active phase-converter configuration and its control that ensures balanced three-phase power supply at the motor terminals under all operating conditions is proposed. Also, this approach has the ability to soft-start the motor. It is shown that this can be done without drawing excessive currents from the power converter or from the single-phase grid. A design methodology is presented for the selection of the autotransformer taps to limit startup transient currents to the desired level, based on the analytical results. Simulation and experimental results are presented that validate the proposed topology and control.


  • Design and comparative study of discrete and module-based IGBT power converters

    by D Venkatramanan, Anil Kumar Adapa, Vinod John


  • Single phase to three phase power conversion using reduced rated inverters

    by Anil K Adapa, Vinod John

    An attractive feature of grid interactive single-phase to three-phase converters is the ability to deliver a fraction of total load power directly from the source. A fixed frequency single-phase to three-phase converter is explored in this paper which reduces the size and cost of the system, and results in better efficiency. This paper proposes control strategy for a three leg single-phase to three-phase converter with active front end converter that leads to reduced converter rating and improved the dc bus utilization. The proposed approach reduces the current rating required by the front end converter by 50%. The results are validated on a laboratory power converter prototype.