Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance
Authors:
- Sami I. BashourSBSami I. Bashour
- Asad KhanAKAsad Khan
- Juhee SongJSJuhee Song
- Gouthami ChintalapaniGCGouthami Chintalapani
- Gerhard KleinszigGKGerhard Kleinszig
- Bruce F. SabathBruce F. Sabath
- Julie LinJLJulie Lin
- Horiana B. GrosuHGHoriana B. Grosu
- Carlos A. JimenezCJCarlos A. Jimenez
- Georgie A. EapenGEGeorgie A. Eapen
- David E. OstDODavid E. Ost
- Mona SarkissMSMona Sarkiss
Open Access
- 4 September 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1955
Abstract
Background: Computed tomography to body divergence (CTBD) is one of the main barriers to bronchoscopic techniques for the diagnosis of peripherally located lung nodules. Cone-beam CT (CBCT) guidance is being rapidly adopted to correct for this phenomenon and to potentially increase diagnostic outcomes. In this trial, we hypothesized that the addition of mobile CBCT (m-CBCT) could improve the rate of tool in lesion (TIL) and the diagnostic yield of shape-sensing robotic-assisted bronchoscopy (SS-RAB). Methods: This was a prospective, single-arm study, which enrolled patients with peripheral lung nodules of 1–3 cm and compared the rate of TIL and the diagnostic yield of SS-RAB alone and combined with mCBCT. Results: A total of 67 subjects were enrolled, the median nodule size was 1.7 cm (range, 0.9–3 cm). TIL was achieved in 23 patients (34.3%) with SS-RAB alone, and 66 patients (98.6%) with the addition of mCBCT (p < 0.0001). The diagnostic yield of SS-RAB alone was 29.9% (95% CI, 29.3–42.3%) and it was 86.6% (95% CI, 76–93.7%) with the addition of mCBCT (p < 0.0001). There were no pneumothoraxes or any bronchoscopy-related complications, and the median total dose–area product (DAP) was 50.5 Gy-cm2. Conclusions: The addition of mCBCT guidance to SS-RAB allows bronchoscopists to compensate for CTBD, leading to an increase in TIL and diagnostic yield, with acceptable radiation exposure.Keywords
Funding Information
- Siemens (P30 CA016672)
- National Computational Infrastructure (P30 CA016672)
This publication has 27 references indexed in Scilit:
- Diagnostic Yield vs Diagnostic Accuracy for Peripheral Lung Biopsy EvaluationChest, 2023
- Guided Bronchoscopy for the Evaluation of Pulmonary LesionsChest, 2023
- Ventilatory Strategy to Prevent Atelectasis During Bronchoscopy Under General AnesthesiaChest, 2022
- Combining Shape-Sensing Robotic Bronchoscopy With Mobile Three-Dimensional Imaging to Verify Tool-in-Lesion and Overcome Divergence: A Pilot StudyMayo Clinic Proceedings: Innovations, Quality & Outcomes, 2022
- Robotic-Assisted Navigation Bronchoscopy as a Paradigm Shift in Peripheral Lung AccessLung, 2021
- Incidence and Location of Atelectasis Developed During Bronchoscopy Under General AnesthesiaChest, 2020
- Sensitivity of Radial Endobronchial Ultrasound-Guided Bronchoscopy for Lung Cancer in Patients With Peripheral Pulmonary LesionsChest, 2020
- Standard Bronchoscopy With Fluoroscopy vs Thin Bronchoscopy and Radial Endobronchial Ultrasound for Biopsy of Pulmonary LesionsChest, 2018
- Feasibility and Safety of the Transbronchial Access Tool for Peripheral Pulmonary Nodule and MassThe Annals of Thoracic Surgery, 2017
- Hybrid DynaCT-guided electromagnetic navigational bronchoscopic biopsyEuropean Journal of Cardio-Thoracic Surgery, 2015