GKGerhard Kleinszig

Gerhard Kleinszig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gerhard Kleinszig has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance

    by Sami I. Bashour, Asad Khan, Juhee Song, Gouthami Chintalapani, Gerhard Kleinszig, Bruce F. Sabath, Julie Lin, Horiana B. Grosu, Carlos A. Jimenez, Georgie A. Eapen, et al.

    Background: Computed tomography to body divergence (CTBD) is one of the main barriers to bronchoscopic techniques for the diagnosis of peripherally located lung nodules. Cone-beam CT (CBCT) guidance is being rapidly adopted to correct for this phenomenon and to potentially increase diagnostic outcomes. In this trial, we hypothesized that the addition of mobile CBCT (m-CBCT) could improve the rate of tool in lesion (TIL) and the diagnostic yield of shape-sensing robotic-assisted bronchoscopy (SS-RAB). Methods: This was a prospective, single-arm study, which enrolled patients with peripheral lung nodules of 1–3 cm and compared the rate of TIL and the diagnostic yield of SS-RAB alone and combined with mCBCT. Results: A total of 67 subjects were enrolled, the median nodule size was 1.7 cm (range, 0.9–3 cm). TIL was achieved in 23 patients (34.3%) with SS-RAB alone, and 66 patients (98.6%) with the addition of mCBCT (p < 0.0001). The diagnostic yield of SS-RAB alone was 29.9% (95% CI, 29.3–42.3%) and it was 86.6% (95% CI, 76–93.7%) with the addition of mCBCT (p < 0.0001). There were no pneumothoraxes or any bronchoscopy-related complications, and the median total dose–area product (DAP) was 50.5 Gy-cm2. Conclusions: The addition of mCBCT guidance to SS-RAB allows bronchoscopists to compensate for CTBD, leading to an increase in TIL and diagnostic yield, with acceptable radiation exposure.


  • Open Access

    Mobile Cone-Beam CT-Assisted Bronchoscopy for Peripheral Lung Lesions

    by Moiz Salahuddin, Sami I. Bashour, Asad Khan, Gouthami Chintalapani, Gerhard Kleinszig, Roberto F. Casal

    Peripheral bronchoscopy with the use of thin/ultrathin bronchoscopes and radial-probe endobronchial ultrasound (RP-EBUS) has been associated with a fair diagnostic yield. Mobile cone-beam CT (m-CBCT) could potentially improve the performance of these readily available technologies. We retrospectively reviewed the records of patients undergoing bronchoscopy for peripheral lung lesions with thin/ultrathin scope, RP-EBUS, and m-CBCT guidance. We studied the performance (diagnostic yield and sensitivity for malignancy) and safety (complications, radiation exposure) of this combined approach. A total of 51 patients were studied. The mean target size was 2.6 cm (SD, 1.3 cm) and the mean distance to the pleura was 1.5 cm (SD, 1.4 cm). The diagnostic yield was 78.4% (95 CI, 67.1–89.7%), and the sensitivity for malignancy was 77.4% (95 CI, 62.7–92.1%). The only complication was one pneumothorax. The median fluoroscopy time was 11.2 min (range, 2.9–42.1) and the median number of CT spins was 1 (range, 1–5). The mean Dose Area Product from the total exposure was 41.92 Gy·cm2 (SD, 11.35 Gy·cm2). Mobile CBCT guidance may increase the performance of thin/ultrathin bronchoscopy for peripheral lung lesions in a safe manner. Further prospective studies are needed to corroborate these findings.


  • Development of a fluoroscopically guided robotic assistant for instrument placement in pelvic trauma surgery

    by Rohan C. Vijayan, Runze Han, Pengwei Wu, Niral M. Sheth, Michael D. Ketcha, Prasad Vagdargi, Sebastian Vogt, Gerhard Kleinszig, Greg M. Osgood, Jeffrey H. Siewerdsen, et al.

    Purpose: A method for fluoroscopic guidance of a robotic assistant is presented for instrument placement in pelvic trauma surgery. The solution uses fluoroscopic images acquired in standard clinical workflow and helps avoid repeat fluoroscopy commonly performed during implant guidance. Approach: Images acquired from a mobile C-arm are used to perform 3D–2D registration of both the patient (via patient CT) and the robot (via CAD model of a surgical instrument attached to its end effector, e.g; a drill guide), guiding the robot to target trajectories defined in the patient CT. The proposed approach avoids C-arm gantry motion, instead manipulating the robot to acquire disparate views of the instrument. Phantom and cadaver studies were performed to determine operating parameters and assess the accuracy of the proposed approach in aligning a standard drill guide instrument. Results: The proposed approach achieved average drill guide tip placement accuracy of 1.57 ± 0.47 mm and angular alignment of 0.35 ± 0.32 deg in phantom studies. The errors remained within 2 mm and 1 deg in cadaver experiments, comparable to the margins of errors provided by surgical trackers (but operating without the need for external tracking). Conclusions: By operating at a fixed fluoroscopic perspective and eliminating the need for encoded C-arm gantry movement, the proposed approach simplifies and expedites the registration of image-guided robotic assistants and can be used with simple, non-calibrated, non-encoded, and non-isocentric C-arm systems to accurately guide a robotic device in a manner that is compatible with the surgical workflow.


  • Evaluation of image quality and task performance for a mobile C-arm with a complementary metal–oxide semiconductor detector

    by Godwin O. Abiola, Niral M. Sheth, Wojciech Zbijewski, Matthew W. Jacobson, Christopher Bailey, John Filtes, Gerhard Kleinszig, Sebastian K. Vogt, Stefan Söllradl, Jens Bialkowski, et al.

    We assessed interventional radiologists’ task-based image quality preferences for two- and three-dimensional images obtained with a complementary metal–oxide semiconductor (CMOS) flat-panel detector versus a hydrogenated amorphous silicon (a-Si:H) flat-panel detector. CMOS and a-Si:H detectors were implemented on identical mobile C-arms to acquire radiographic, fluoroscopic, and cone-beam computed tomography (CBCT) images of cadavers undergoing simulated interventional procedures using low- and high-dose settings. Images from both systems were displayed side by side on calibrated, diagnostic-quality displays, and three interventional radiologists evaluated task performance relevant to each image and ranked their preferences based on visibility of pertinent anatomy and interventional devices. Overall, CMOS images were preferred in fluoroscopy (p = 0.002) and CBCT (p = 0.004), at low-dose settings (p = 0.001), and for tasks associated with high levels of spatial resolution [e.g., fine anatomical details (p = 0.006) and assessment of interventional devices (p = 0.015)]. No significant difference was found for fluoroscopic imaging tasks emphasizing temporal resolution (p = 0.072), for radiography tasks (p = 0.825), when using high-dose settings (p = 0.360), or tasks involving general anatomy (p = 0.174). The image quality preferences are consistent with reported technical advantages of CMOS regarding finer pixel size and reduced electronic noise.


  • Learning-based deformable image registration: effect of statistical mismatch between train and test images

    by Michael D. Ketcha, Tharindu S. De Silva, Runze Han, Ali Uneri, Sebastian Vogt, Gerhard Kleinszig, Jeffrey H. Siewerdsen

    Convolutional neural networks (CNNs) offer a promising means to achieve fast deformable image registration with accuracy comparable to conventional, physics-based methods. A persistent question with CNN methods, however, is whether they will be able to generalize to data outside of the training set. We investigated this question of mismatch between train and test data with respect to first- and second-order image statistics (e.g., spatial resolution, image noise, and power spectrum). A UNet-based architecture was built and trained on simulated CT images for various conditions of image noise (dose), spatial resolution, and deformation magnitude. Target registration error was measured as a function of the difference in statistical properties between the test and training data. Generally, registration error is minimized when the training data exactly match the statistics of the test data; however, networks trained with data exhibiting a diversity in statistical characteristics generalized well across the range of statistical conditions considered. Furthermore, networks trained on simulated image content with first- and second-order statistics selected to match that of real anatomical data were shown to provide reasonable registration performance on real anatomical content, offering potential new means for data augmentation. Characterizing the behavior of a CNN in the presence of statistical mismatch is an important step in understanding how these networks behave when deployed on new, unobserved data. Such characterization can inform decisions on whether retraining is necessary and can guide the data collection and/or augmentation process for training.