Abstract
OBJECTIVE. This article describes the time course of lesion detection on digital mammograms using data about both eye position and decision time to compare performance between experienced mammographers and trainees. Research indicates that a longer decision time works against performance in the interpretation of chest radiographs because the likelihood of error is increased, particularly for trainees. Is this relation between decision time and performance also true for interpreting mammograms? Is there an optimal decision time—performance trade-off for detecting breast lesions?MATERIALS AND METHODS. Six radiology trainees (experience, 302-976 cases) and three mammographers (experience, 3000-5000 cases per year) reviewed 40 test cases. Each test case was represented by two mammograms that showed different views of the same breast. Twenty breasts contained suspicious lesions, and 20 were lesion-free. An interactive computer display system with an eye—head tracker measured the timing of decisions, where visu...

This publication has 11 references indexed in Scilit: