Assessment of flow pattern of right ventricle outflow and pulmonary arteries in surgically corrected tetralogy of Fallot patients by four-dimensional cardiac magnetic resonance flow
Open Access
- 7 September 2020
- journal article
- research article
- Published by Springer Nature in The Egyptian Heart Journal
- Vol. 72 (1) , 1-7
Abstract
Background: The most common post-surgical complication of tetralogy of Fallot (TOF) is pulmonary regurgitation (PR) which can lead to right ventricle (RV) dysfunction/failure. Cardiac magnetic resonance (CMR) is the imaging modality of choice to follow-up a repaired TOF. However, the conventional two-dimensional phase-contrast (2D-PC) flow usually underestimates PR as well as the pulmonary peak systolic velocity (PSV). Recently, four-dimensional (4D) CMR flow is introduced for more accurate quantitative flow assessment. This work aimed to compare between 4D-CMR and 2D-PC flow across the main (MPA), right (RPA), and left (LPA) pulmonary arteries (PAs) in surgically corrected TOF patients. Results: This study was conducted on 20 repaired TOF patients (range 3–9 years, 50% males). All patients had CMR exam on 1.5T scanner. 4D-CMR and 2D-PC flows were obtained at the proximal segments of the MPA, RPA, and LPA. The stroke volume index (SVI), regurgitation fraction (RF), and PSV measured by 4D-CMR were compared to 2D-PC flow. The SVI across the PAs was nearly similar between both methods (P = 0.179 for MPA, 0.218 for RPA, and 0.091 for LPA). However, the RF was significantly higher by 4D-CMR in comparison to 2D-PC flow (P = 0.027 for MPA, 0.039 for RPA, and 0.046 for LPA). The PSV as well was significantly higher by 4D-CMR flow (P = 0.003 for MPA, < 0.001 for RPA, and 0.002 for LPA). The Bland-Altman plots showed a good agreement between 4D-CMR and 2D-PC flow for the SVI, RF, and PSV across the pulmonary arteries. Conclusion: A good agreement existed between the two studied methods regarding pulmonary flow measurements. Because of its major advantage of performing a comprehensive flow assessment in a shorter time, 4D-CMR flow plays an important role in the assessment of patients with complex CHD especially in the pediatric group.Keywords
This publication has 16 references indexed in Scilit:
- Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteriesEuropean Radiology, 2013
- Intracardiac flow visualization: current status and future directionsEuropean Heart Journal - Cardiovascular Imaging, 2013
- 4-D MRI flow analysis in the course of interrupted aortic arch reveals complex morphology and quantifies amount of collateral blood flowPediatric Radiology, 2013
- Four‐dimensional velocity‐encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flowJournal of Magnetic Resonance Imaging, 2012
- Recommendations for cardiovascular magnetic resonance in adults with congenital heart disease from the respective working groups of the European Society of CardiologyEuropean Heart Journal, 2010
- Tetralogy of FallotThe Lancet, 2009
- Repaired tetralogy of Fallot in the adult: monitoring and managementHeart, 2008
- Time‐resolved 3D MR velocity mapping at 3T: Improved navigator‐gated assessment of vascular anatomy and blood flowJournal of Magnetic Resonance Imaging, 2007
- Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imagingJACC, 2002
- The First Open-Heart Repairs of Ventricular Septal Defect, Atrioventricular Communis, and Tetralogy of Fallot Using Extracorporeal Circulation by Cross-Circulation: A 30-Year Follow-upThe Annals of Thoracic Surgery, 1986