Full receiver operating characteristic curve estimation using two alternative forced choice studies
- 1 January 2016
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 3 (1) , 011010
Abstract
Task-based medical image quality is typically measured by the degree to which a human observer can perform a diagnostic task in a psychophysical human observer study. During a typical study, an observer is asked to provide a numerical score quantifying his confidence as to whether an image contains a diagnostic marker or not. Such scores are then used to measure the observers’ diagnostic accuracy, summarized by the receiver operating characteristic (ROC) curve and the area under ROC curve. These types of human studies are difficult to arrange, costly, and time consuming. In addition, human observers involved in this type of study should be experts on the image genre to avoid inconsistent scoring through the lengthy study. In two-alternative forced choice (2AFC) studies, known to be faster, two images are compared simultaneously and a single indicator is given. Unfortunately, the 2AFC approach cannot lead to a full ROC curve or a set of image scores. The aim of this work is to propose a methodology in which multiple rounds of the 2AFC studies are used to re-estimate an image confidence score (a.k.a. rating, ranking) and generate the full ROC curve. In the proposed approach, we treat image confidence score as an unknown rating that needs to be estimated and 2AFC as a two-player match game. To achieve this, we use the ELO rating system, which is used for calculating the relative skill levels of players in competitor-versus-competitor games such as chess. The proposed methodology is not limited to ELO, and other rating methods such as TrueSkill™, Chessmetrics, or Glicko can be also used. The presented results, using simulated data, indicate that a full ROC curve can be recovered using several rounds of 2AFC studies and that the best pairing strategy starts with the first round of pairing abnormal versus normal images (as in the classical 2AFC approach) followed by a number of rounds using random pairing. In addition, the proposed method was tested in a pilot human observer study. These pilot results indicate that three to five rounds of 2AFC studies require less human observer time than a full scoring study and that the re-estimated ROC curves and associated area under ROC curve values have high statistical agreement with the full scoring study.Keywords
Funding Information
- National Institutes of Health (HL0654425)
- National Institutes of Health (HL 091017)
- National Institutes of Health (HL122484)
This publication has 14 references indexed in Scilit:
- Numerical Surrogates for Human Observers in Myocardial Motion Evaluation From SPECT ImagesIEEE Transactions on Medical Imaging, 2013
- Generalization Evaluation of Machine Learning Numerical Observers for Image Quality AssessmentIEEE Transactions on Nuclear Science, 2013
- Machine Learning in Medical ImagingIEEE Signal Processing Magazine, 2010
- Testing signal-detection models of yes/no and two-alternative forced-choice recognition memory.Journal of Experimental Psychology: General, 2009
- Learning a Channelized Observer for Image Quality AssessmentIEEE Transactions on Medical Imaging, 2009
- The partial area under the summary ROC curveStatistics in Medicine, 2005
- Efficiency of the human observer detecting random signals in random backgroundsJournal of the Optical Society of America A, 2005
- Comparison of receiver operating characteristic and forced choice observer performance measurement methodsMedical Physics, 1995
- Practical Issues of Experimental ROC Analysis Selection of ControlsInvestigative Radiology, 1990
- The meaning and use of the area under a receiver operating characteristic (ROC) curve.Radiology, 1982