Jovan G. Brankov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jovan G. Brankov has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth M. Tichauer
Lawson Research Institute, St. Joseph’s Health Care London, London, ON, Canada
4 shared publications - Cody C. Rounds
Department of Biomedical Engineering, Oregon Health and Science University (OHSU), Portland OR 97239, USA
3 shared publications Keivan Majidi
ECE Department, Illinois Institute of Technology, Chicago, Illinois 60616, USA
3 shared publicationsMiles N. Wernick
Illinois Institute of Technology, Medical Imaging Research Center, Department of Electrical and Computer Engineering, Chicago, Illinois 60616, United States
3 shared publicationsThibault Marin
Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
3 shared publicationsYongyi Yang
Illinois Institute of Technology (United States)
3 shared publications
Latest Publications
- Open Access
- 29 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (04) , 046001-16
Dual-channel pulse-dye densitometry can enable correction of fluorescent targeted and control agent plasma input function differences for quantitative paired-agent molecular imaging: a simulation study
In recent years, paired-agent imaging (PAI) strategies have been explored owing to their ability to yield quantitative in vivo imaging of cell-surface receptors.1 – 3 PAI requires the administration of at least two imaging agents of similar blood and tissue kinetics where one agent is targeted to a biomolecule of interest and one is untargeted (the “control” agent). By measuring the dynamics of the control agent, non-specific accumulation of the targeted agent and variable targeted agent delivery (attributable to the variability of blood flow and vascular permeability among tissues, particularly cancerous tissues) can potentially be accounted for, allowing for more quantitative estimates of the targeted agent’s specific binding through the approximation of a quantity termed the “binding potential” (BP). BP is directly proportional to the concentration of an agent’s biomolecular target,4 and as such, the measurement of this quantity can give critical insight into the disease state and phenotype of a biological tissue. In the context of surgical oncology, BP mapping (compared with targeted agent distribution mapping) may enable improved discrimination between malignant and non-malignant tissue types.5,6
- 29 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (04) , 046001-16
Open AccessDual-channel pulse-dye densitometry can enable correction of fluorescent targeted and control agent plasma input function differences for quantitative paired-agent molecular imaging: a simulation study
In recent years, paired-agent imaging (PAI) strategies have been explored owing to their ability to yield quantitative in vivo imaging of cell-surface receptors.1 – 3 PAI requires the administration of at least two imaging agents of similar blood and tissue kinetics where one agent is targeted to a biomolecule of interest and one is untargeted (the “control” agent). By measuring the dynamics of the control agent, non-specific accumulation of the targeted agent and variable targeted agent delivery (attributable to the variability of blood flow and vascular permeability among tissues, particularly cancerous tissues) can potentially be accounted for, allowing for more quantitative estimates of the targeted agent’s specific binding through the approximation of a quantity termed the “binding potential” (BP). BP is directly proportional to the concentration of an agent’s biomolecular target,4 and as such, the measurement of this quantity can give critical insight into the disease state and phenotype of a biological tissue. In the context of surgical oncology, BP mapping (compared with targeted agent distribution mapping) may enable improved discrimination between malignant and non-malignant tissue types.5,6
- Open Access
- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016003-10
Improved intraoperative identification of close margins in oral squamous cell carcinoma resections using a dual aperture fluorescence ratio approach: first in-human results
Over 370,000 new cases of oral squamous cell carcinomas (OSCC) were reported in 2020.1 The primary treatment for these tumors is surgical resection. 2 Yet, owing to the complex anatomy of the head and neck, complete resection of primary tumors is challenging and inadequate margins are observed in up to 40% of cases.3 – 5 These include both positive margins (tumor within 1 mm of the edge of the resected specimen) and close margins (tumor between 1 and 5 mm of the edge of the resected specimen).6,7 In cases where inadequate margins are found (any thick), patients often require intensive adjuvant therapy8 because a secondary surgery is typically not possible due to altered anatomy or the proximity of vital structures. In either scenario, patient outcomes are generally worse than if clear margins were obtained on the initial surgery.9- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016003-10
Open AccessImproved intraoperative identification of close margins in oral squamous cell carcinoma resections using a dual aperture fluorescence ratio approach: first in-human results
Over 370,000 new cases of oral squamous cell carcinomas (OSCC) were reported in 2020.1 The primary treatment for these tumors is surgical resection. 2 Yet, owing to the complex anatomy of the head and neck, complete resection of primary tumors is challenging and inadequate margins are observed in up to 40% of cases.3 – 5 These include both positive margins (tumor within 1 mm of the edge of the resected specimen) and close margins (tumor between 1 and 5 mm of the edge of the resected specimen).6,7 In cases where inadequate margins are found (any thick), patients often require intensive adjuvant therapy8 because a secondary surgery is typically not possible due to altered anatomy or the proximity of vital structures. In either scenario, patient outcomes are generally worse than if clear margins were obtained on the initial surgery.9 - Open Access
- 19 October 2023
- Published by Wiley in Animal Models and Experimental Medicine
- Vol. 6 (5) , 427-432
A cadaveric breast cancer tissue phantom for phase‐contrast X‐ray imaging applications
Background: As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues, a need has developed for reliable imaging phantoms for use in system design and component calibration. In advanced imaging modalities such as refraction-based methods, it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production. This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods: Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results: The resulting human-murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging. Digital breast tomosynthesis was also performed.Conclusion: Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.
- 19 October 2023
- Published by Wiley in Animal Models and Experimental Medicine
- Vol. 6 (5) , 427-432
Open AccessA cadaveric breast cancer tissue phantom for phase‐contrast X‐ray imaging applications
Background: As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues, a need has developed for reliable imaging phantoms for use in system design and component calibration. In advanced imaging modalities such as refraction-based methods, it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production. This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods: Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results: The resulting human-murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging. Digital breast tomosynthesis was also performed.Conclusion: Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.
- Open Access
- 30 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (03) , 031501-3
Special Section Guest Editorial: Hard X-Ray Tomography with Micrometer Resolution
JMI guest editors introduce articles collected in the JMI Special Section on Hard X-Ray Tomography with Micrometer Resolution, a snapshot of this important niche area.
- 30 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 9 (03) , 031501-3
Open AccessSpecial Section Guest Editorial: Hard X-Ray Tomography with Micrometer Resolution
JMI guest editors introduce articles collected in the JMI Special Section on Hard X-Ray Tomography with Micrometer Resolution, a snapshot of this important niche area.
- 21 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (6) , 1799-1810
Do CNNs Solve the CT Inverse Problem?
Objective: This work examines the claim made in the literature that the inverse problem associated with image reconstruction in sparse-view computed tomography (CT) can be solved with a convolutional neural network (CNN). Methods: Training, and testing image/data pairs are generated in a dedicated breast CT simulation for sparse-view sampling, using two different object models. The trained CNN is tested to see if images can be accurately recovered from their corresponding sparse-view data. For reference, the same sparse-view CT data is reconstructed by the use of constrained total-variation (TV) minimization (TVmin), which exploits sparsity in the gradient magnitude image (GMI). Results: There is a significant discrepancy between the image obtained with the CNN and the image that generated the data. TVmin is able to accurately reconstruct the test images. Conclusion: We find that the sparse-view CT inverse problem cannot be solved for the particular published CNN-based methodology that we chose, and the particular object model that we tested. Significance: The inability of the CNN to solve the inverse problem associated with sparse-view CT, for the specific conditions of the presented simulation, draws into question similar unsupported claims being made for the use of CNNs and deep-learning to solve inverse problems in medical imaging.
- 21 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (6) , 1799-1810
Do CNNs Solve the CT Inverse Problem?
Objective: This work examines the claim made in the literature that the inverse problem associated with image reconstruction in sparse-view computed tomography (CT) can be solved with a convolutional neural network (CNN). Methods: Training, and testing image/data pairs are generated in a dedicated breast CT simulation for sparse-view sampling, using two different object models. The trained CNN is tested to see if images can be accurately recovered from their corresponding sparse-view data. For reference, the same sparse-view CT data is reconstructed by the use of constrained total-variation (TV) minimization (TVmin), which exploits sparsity in the gradient magnitude image (GMI). Results: There is a significant discrepancy between the image obtained with the CNN and the image that generated the data. TVmin is able to accurately reconstruct the test images. Conclusion: We find that the sparse-view CT inverse problem cannot be solved for the particular published CNN-based methodology that we chose, and the particular object model that we tested. Significance: The inability of the CNN to solve the inverse problem associated with sparse-view CT, for the specific conditions of the presented simulation, draws into question similar unsupported claims being made for the use of CNNs and deep-learning to solve inverse problems in medical imaging.
- Open Access
Do CNNs solve the CT inverse problem?
Objective: This work examines the claim made in the literature that the inverse problem associated with image reconstruction in sparse-view computed tomography (CT) can be solved with a convolutional neural network (CNN). Methods: Training and testing image/data pairs are generated in a dedicated breast CT simulation for sparse-view sampling, using two different object models. The trained CNN is tested to see if images can be accurately recovered from their corresponding sparse-view data. For reference, the same sparse-view CT data is reconstructed by the use of constrained total-variation (TV) minimization (TVmin), which exploits sparsity in the gradient magnitude image (GMI). Results: Using sparse-view data from images either in the training or testing set, there is a significant discrepancy between the image obtained with the CNN and the image that generated the data. For the same simulated scanning conditions, TVmin is able to accurately reconstruct the test image. Conclusion: We find that the sparse-view CT inverse problem cannot be solved for the particular published CNN-based methodology that we chose and the particular object model that we tested. Furthermore, this negative result is obtained for conditions where TVmin is able to recover the test images. Significance: The inability of the CNN to solve the inverse problem associated with sparse-view CT, for the specific conditions of the presented simulation, draws into question similar unsupported claims being made for the use of CNNs to solve inverse problems in medical imaging.
Open AccessDo CNNs solve the CT inverse problem?
Objective: This work examines the claim made in the literature that the inverse problem associated with image reconstruction in sparse-view computed tomography (CT) can be solved with a convolutional neural network (CNN). Methods: Training and testing image/data pairs are generated in a dedicated breast CT simulation for sparse-view sampling, using two different object models. The trained CNN is tested to see if images can be accurately recovered from their corresponding sparse-view data. For reference, the same sparse-view CT data is reconstructed by the use of constrained total-variation (TV) minimization (TVmin), which exploits sparsity in the gradient magnitude image (GMI). Results: Using sparse-view data from images either in the training or testing set, there is a significant discrepancy between the image obtained with the CNN and the image that generated the data. For the same simulated scanning conditions, TVmin is able to accurately reconstruct the test image. Conclusion: We find that the sparse-view CT inverse problem cannot be solved for the particular published CNN-based methodology that we chose and the particular object model that we tested. Furthermore, this negative result is obtained for conditions where TVmin is able to recover the test images. Significance: The inability of the CNN to solve the inverse problem associated with sparse-view CT, for the specific conditions of the presented simulation, draws into question similar unsupported claims being made for the use of CNNs to solve inverse problems in medical imaging.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11312, 1131250-181
Comparison of the phase and absorption contrast tomographic reconstruction
Analyzer-based Imaging (ABI) belongs to a broader family of phase-contrast (PC) X-ray techniques. PC measures X-ray deflection phenomena when interacting with tissue, which is known to provide higher contrast images of soft tissue than other X-ray methods. This has a very important interest in the medical field, specially for mammogram applications. This paper presents a simulation study to compare the sensitivity of filtered back projection of absorption based imaging (implemented by FDK - a method usually used in the conventional X-ray computed tomography) and the phase contrast tomographic imaging. These results are based on previously proposed simulation tool for a table-top ABI systems using a conventional polychromatic X-ray source. In our experiments we evaluated images obtained under different errors in reconstruction parameters namely: the detector’s offset in position, the distance source to the detector (DSD) or source to the object (DSO).
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11312, 1131250-181
Comparison of the phase and absorption contrast tomographic reconstruction
Analyzer-based Imaging (ABI) belongs to a broader family of phase-contrast (PC) X-ray techniques. PC measures X-ray deflection phenomena when interacting with tissue, which is known to provide higher contrast images of soft tissue than other X-ray methods. This has a very important interest in the medical field, specially for mammogram applications. This paper presents a simulation study to compare the sensitivity of filtered back projection of absorption based imaging (implemented by FDK - a method usually used in the conventional X-ray computed tomography) and the phase contrast tomographic imaging. These results are based on previously proposed simulation tool for a table-top ABI systems using a conventional polychromatic X-ray source. In our experiments we evaluated images obtained under different errors in reconstruction parameters namely: the detector’s offset in position, the distance source to the detector (DSD) or source to the object (DSO).
- Open Access
- 8 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (11) , 110501-4
Angular restriction fluorescence optical projection tomography to localize micrometastases in lymph nodes
<!-- *** Custom HTML *** --> Lymph node biopsy is a primary means of staging breast cancer, yet standard pathological techniques are time-consuming and typically sample less than 1% of the total node volume. A low-cost fluorescence optical projection tomography (OPT) protocol is demonstrated for rapid imaging of whole lymph nodes in three dimensions. The relatively low scattering properties of lymph node tissue can be leveraged to significantly improve spatial resolution of lymph node OPT by employing angular restriction of photon detection. It is demonstrated through porcine lymph node metastases models that simple filtered-backprojection reconstruction is sufficient to detect and localize 200-μm-diameter metastases (the smallest clinically significant) in 1-cm-diameter lymph nodes. Timely and accurate diagnoses of metastatic cancer have proven to be the single greatest influencer of positive therapeutic outcomes, improving 5-year survival rates by more than 10%; thus, more sensitive methods for detecting cancer spread are of significant clinical interest.1,2 The current standard for identifying metastases in breast cancer (and a number of other cancers) is through pathological assessment of sentinel lymph node biopsy (SLNB) tissues. Typically, excised lymph nodes located during tumor resection surgery are cut to 2-mm-thick sections, processed, and stained with hemotoxylin and eosin for pathology reading (total process takes 24 h with pathologist read time of 1 to 2 min).3,4 While this yields an analysis of only 1% of the lymph node volume, there is evidence that only macrometastases (cancer cell clusters of greater than 2 mm in diameter) have clinical relevance.1,5,6 Yet, other works have indicated that micrometastases (0.2 to 2 mm in diameter) also have clinical relevance.7,8 For more rapid assessments, frozen section pathology has become widely adopted,4 yet sensitivity and specificity have been reported to be variable from institute to institute,4,6 and 2-mm node sectioning only ensures detection of macrometastases. Micrometastasis detection could be ensured by sectioning nodes at 0.2 mm; however, this would make pathologist reading time go from 1 to 2 min to 10 to 20 min. A more accurate and rapid method to detect both micro- and macrometastases could help overcome these challenges. Optical projection tomography (OPT) offers a potential solution for rapid, whole sample evaluation. As demonstrated by Kokolakis et al.,9 optical computed tomography was used to successfully distinguish between malignant and benign lesions in skin biopsies, as well as the extent of invasion, prior to histology through evaluation of reconstructed total attenuation coefficient maps. OPT along with fluorescence (emission-OPT) has been used extensively to provide three-dimensional (3-D) visualization of mesoscopic-sized samples with microscopic resolution. For instance, imaging of individual islets, microvasculature, and gene expression from whole rodent organs, embryos, and xenograft tumors were achieved;10 – 12 fluorescence lifetime imaging with OPT enabled functional imaging of biological samples;13,14 and to push the limits of resolution further, methods of light sheet microscopy, such as selective plane illumination microscopy, have been combined with OPT.15 – 17 Such techniques have even been used in ex vivo lymph node samples to visualize vascular networks and quantify cellularity.17,18 All of these works, however, require the sample to be optically cleared, a process which is both time and labor intensive.19 To combat this, methods of mesoscopic fluorescence tomography make use of mathematical models of photon propagation or other computational techniques to permit imaging of nontransparent samples.20 – 22 While these have demonstrated an ability to achieve necessary levels of spatial resolution, performance relies heavily on accurate modeling that can make image reconstruction computationally expensive. Alternatively, scatter rejection methods in the time 23,24 and angular domains25 yield lower photon budgets but have the potential to be effective with very low-cost instrumentation and simple filtered-backprojection (FBP) for image reconstruction. In time-domain rejection, only the earliest arriving photons, through optical or electronic gating, are measured. On the other hand, in angular-domain rejection, only the straightest traveling photons, by restricting the detector’s acceptance angle, are measured. Since there is a trade-off between the level of scatter rejection and measured number of photons, the amount of spatial resolution enhancement and manner in which it is achieved (time or angle restriction) depends on the application. Specifically, for objects with the size and optical properties of lymph nodes, it has been demonstrated, in absorption-based OPT simulation study, that angular restriction with a numerical aperture (NA) = 0.005 is sufficient to detect and localize 0.2-mm-diameter objects.26 While small NA is common in standard OPT to maximize depth of field, the level required for scatter rejection as demonstrated in the aforementioned study is an order of magnitude lower than what is typically used. Using the time-resolved lymph node transmittance optical property measurements and OPT system optimization (e.g., NA and associated optical components) with Monte Carlo simulation in the work done by Sinha et al.,26 a fluorescence-based simulation study was conducted where it was demonstrated that up to 100% detectability and 95% localization of 0.2-mm micrometastases in 10-mm-diameter nodes could be achieved with FBP reconstruction.27 These predictions were generated from a system configuration with expanded beam illumination, no time restriction, a detection , and clinically feasible levels of fluorescence contrast (100 nM); therefore, verifying the potential for implementation of a simple, low-cost, and relatively quick system with the ability to detect and localize the smallest clinically significant metastases. The work presented here capitalizes on this finding for the development of a lymph node imaging protocol using angular restriction fluorescence OPT. In conjunction with this, we have been developing paired-agent strategies for microscopic sensitivity to cancer cells in lymph nodes both in vivo28 and ex vivo; however, its details are outside the scope of this paper. To demonstrate the advantage of scatter rejection in the angular domain for lymph node applications, fluorescence imaging was done on various porcine tissues using no restriction () and strict angular restriction (). Approximately 0.2-mm-diameter fluorescent agarose inclusions composed of IRDye 800CW (LI-COR Biosciences) were embedded as accurately as possible in the center of similar sized ( thick) lymph node, muscle, and fat tissues. The samples were suspended in transparent 1% agarose gel and placed on a motorized rotation stage for imaging on the in-house made angular restricted OPT system [schematic shown in Fig. 1(a)]. A 780-nm laser (FPL-02RFF1 Calmar Laser, Medocino, Palo Alto, California) was passed through a 10-nm-bandpass excitation filter (Chroma Technology, Rockingham, Vermont) and expanded using a Keplerian lens system [25- and 300-mm focal length lens (all lenses from ThorLabs, Newton, New Jersey)] to a beam waist of 2.4 cm, to illuminate the whole surface of the tissue from one direction. Fluorescent light exiting the sample was collected directly opposite the illumination using a telecentric lens system (100- to 25-mm focal length lens) to focus down the light through an aperture before reaching the camera (sCMOS; Quantalux, ThorLabs). A continuously variable iris diaphragm (CP20S, ThorLabs) served as an aperture to restrict detection NA and was positioned between the lenses, at the focal length of each yielding an for no restriction or for strict restriction. Emission light was filtered using a 45-nm notch filter centered at 780 nm (Chroma Technology). Camera exposure time was set to 1 s for images with no restriction and 5 s when strict restriction was implemented. All raw fluorescence signals in each setup were scaled independently and thresholded for visualization purposes such that 90% of the fluorescence range above the background is shown. <!-- named anchor --> Fig. 1 (a) System schematic. (b) Experimental protocol. Results for each of the different tissue types using no angular restriction and strict angular restriction are presented in Fig. 2. It can be seen that with a completely open iris diaphragm, the fluorescent signal was more diffuse than when scatter rejection was employed with a closed iris. Figures 2(c), 2(f), and 2(i) compare fluorescence intensity line profile plots for each system configuration (no versus strict angular restrictions) in lymph node tissue, fat tissue, and muscle tissue, respectively. Profiles were calculated as the average of 100 rows at 0 deg, 45 deg, 90 deg, and 125 deg across each image, for a total of four measurements (only the 0-deg profiles are plotted in Fig. 2); mean values of full width at half maximum (FWHM) ± standard deviation are summarized in Table 1. Lymph node tissue presented the greatest decrease () in FWHM when going from to 0.005, muscle tissue was least impacted ( decrease), and fat fell between the two, with a improvement. The results were consistent with what was expected based on tissue optical properties, namely scattering; where compared to soft tissue-like muscle and fat, lymph nodes are much lower scattering in nature (, , at 780 nm26). Reported values for piglet muscle are , , and , , measured at 630 and 632.8 nm, respectively.29 Human subcutaneous adipose tissue, meanwhile, had reduced scattering coefficients between 11.3 and at 780 nm.29 The anisotropy factor was not provided; however, using the average value for biological tissue (), an estimated average of could be deduced. Overall, an inverse relationship was found between scattering properties and resolution improvement with angular restriction; that is, as scattering increased, the difference in FWHM with and without angular restriction decreased. Muscle tissue revealed relatively similar results with and without scatter rejection, which can be attributed to its high “scattering power”—a parameter used to characterize the reduced scattering coefficient, , in Jacques’ in-depth review of biological tissue optical properties.30 In fact, muscle had reported a 2.7 times greater scattering power than fatty tissue. Fat, which had intermediate scattering properties, therefore showed improvements between that of lymph nodes and muscle. These findings support the conclusions of the previous simulation study26 in that angle restriction is an appropriate scatter rejection method specifically for lymph node applications because of its mesoscopic size and low scattering optical properties. While the resolution is obviously not sufficient to localize the inclusions from these single projections, based on the aforementioned simulation,27 it is expected that, upon tomography and reconstruction, they would be detected and localized with ease. <!-- named anchor --> Fig. 2 Porcine tissues (top row, lymph node; middle row, fat; and bottom row, muscle) embedded with a fluorescent inclusion. Tissues are ordered to represent expected levels of optical scattering increasing from top to bottom. Columns display: false-colored fluorescence images from a single tomographic view using (a), (d), (g) no angular restriction (); (b), (e), (h) strict angular restriction (). (c), (f), (i) Corresponding line profiles of normalized signal intensity. Tissue structures are outlined in white and scale bars are all 2 mm. Dashed lines indicate the center of 100 averaged rows of the intensity profiles plotted for zero and strict constriction in blue and red, respectively. <!-- named anchor --> Table 1 Values of FWHM of fluorescence intensity profiles for tissues with a fluorescent inclusion. Tissue FHWM (mm) NA=0.133 NA=0.005 Lymph node Fat Muscle To test this, experiments were conducted with a porcine lymph node metastases model [Fig. 1(b)]. A human breast cancer cell line (MDA-MB-231) with known elevated expression of epidermal growth factor receptor (EGFR) was transfected with green fluorescent protein (GFP) and grown in 3-D cell culture so that cells could form spheroids to mimic the architecture of metastases. The spheroids were allowed to grow to a diameter of . They were then stained for 60 min with a 100-nM solution of targeted fluorescent dye [IRDye 800DX-labeled cetuximab (an anti-EGFR antibody)] and rinsed with phosphate-buffered saline for 5 min before being implanted in two spots of lymph nodes excised from fresh porcine neck tissue acquired from a local butcher (). Inclusions were placed more superficially for whole node wide-field fluorescence imaging (Pearl, LI-COR, Lincoln, Nebraska) to verify successful implantation. The same imaging procedure described above was carried out, except only strict restriction was applied () and tomography was employed by capturing images in 5-deg intervals over 360 deg for a total of 72 tomographic views. The same collection range was applied for absorption images (no fluorescence filter). Reconstruction was done on both (fluorescence and absorption) data sets using FBP to create 3-D fluorescence maps of the micromets and to recreate the node volume for structural context. Two-dimensional (2-D) slices at the height of detected cells were also reconstructed. Following imaging, the samples were frozen-sectioned in OCT at -thick slices and...- 8 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (11) , 110501-4
Open AccessAngular restriction fluorescence optical projection tomography to localize micrometastases in lymph nodes
<!-- *** Custom HTML *** --> Lymph node biopsy is a primary means of staging breast cancer, yet standard pathological techniques are time-consuming and typically sample less than 1% of the total node volume. A low-cost fluorescence optical projection tomography (OPT) protocol is demonstrated for rapid imaging of whole lymph nodes in three dimensions. The relatively low scattering properties of lymph node tissue can be leveraged to significantly improve spatial resolution of lymph node OPT by employing angular restriction of photon detection. It is demonstrated through porcine lymph node metastases models that simple filtered-backprojection reconstruction is sufficient to detect and localize 200-μm-diameter metastases (the smallest clinically significant) in 1-cm-diameter lymph nodes. Timely and accurate diagnoses of metastatic cancer have proven to be the single greatest influencer of positive therapeutic outcomes, improving 5-year survival rates by more than 10%; thus, more sensitive methods for detecting cancer spread are of significant clinical interest.1,2 The current standard for identifying metastases in breast cancer (and a number of other cancers) is through pathological assessment of sentinel lymph node biopsy (SLNB) tissues. Typically, excised lymph nodes located during tumor resection surgery are cut to 2-mm-thick sections, processed, and stained with hemotoxylin and eosin for pathology reading (total process takes 24 h with pathologist read time of 1 to 2 min).3,4 While this yields an analysis of only 1% of the lymph node volume, there is evidence that only macrometastases (cancer cell clusters of greater than 2 mm in diameter) have clinical relevance.1,5,6 Yet, other works have indicated that micrometastases (0.2 to 2 mm in diameter) also have clinical relevance.7,8 For more rapid assessments, frozen section pathology has become widely adopted,4 yet sensitivity and specificity have been reported to be variable from institute to institute,4,6 and 2-mm node sectioning only ensures detection of macrometastases. Micrometastasis detection could be ensured by sectioning nodes at 0.2 mm; however, this would make pathologist reading time go from 1 to 2 min to 10 to 20 min. A more accurate and rapid method to detect both micro- and macrometastases could help overcome these challenges. Optical projection tomography (OPT) offers a potential solution for rapid, whole sample evaluation. As demonstrated by Kokolakis et al.,9 optical computed tomography was used to successfully distinguish between malignant and benign lesions in skin biopsies, as well as the extent of invasion, prior to histology through evaluation of reconstructed total attenuation coefficient maps. OPT along with fluorescence (emission-OPT) has been used extensively to provide three-dimensional (3-D) visualization of mesoscopic-sized samples with microscopic resolution. For instance, imaging of individual islets, microvasculature, and gene expression from whole rodent organs, embryos, and xenograft tumors were achieved;10 – 12 fluorescence lifetime imaging with OPT enabled functional imaging of biological samples;13,14 and to push the limits of resolution further, methods of light sheet microscopy, such as selective plane illumination microscopy, have been combined with OPT.15 – 17 Such techniques have even been used in ex vivo lymph node samples to visualize vascular networks and quantify cellularity.17,18 All of these works, however, require the sample to be optically cleared, a process which is both time and labor intensive.19 To combat this, methods of mesoscopic fluorescence tomography make use of mathematical models of photon propagation or other computational techniques to permit imaging of nontransparent samples.20 – 22 While these have demonstrated an ability to achieve necessary levels of spatial resolution, performance relies heavily on accurate modeling that can make image reconstruction computationally expensive. Alternatively, scatter rejection methods in the time 23,24 and angular domains25 yield lower photon budgets but have the potential to be effective with very low-cost instrumentation and simple filtered-backprojection (FBP) for image reconstruction. In time-domain rejection, only the earliest arriving photons, through optical or electronic gating, are measured. On the other hand, in angular-domain rejection, only the straightest traveling photons, by restricting the detector’s acceptance angle, are measured. Since there is a trade-off between the level of scatter rejection and measured number of photons, the amount of spatial resolution enhancement and manner in which it is achieved (time or angle restriction) depends on the application. Specifically, for objects with the size and optical properties of lymph nodes, it has been demonstrated, in absorption-based OPT simulation study, that angular restriction with a numerical aperture (NA) = 0.005 is sufficient to detect and localize 0.2-mm-diameter objects.26 While small NA is common in standard OPT to maximize depth of field, the level required for scatter rejection as demonstrated in the aforementioned study is an order of magnitude lower than what is typically used. Using the time-resolved lymph node transmittance optical property measurements and OPT system optimization (e.g., NA and associated optical components) with Monte Carlo simulation in the work done by Sinha et al.,26 a fluorescence-based simulation study was conducted where it was demonstrated that up to 100% detectability and 95% localization of 0.2-mm micrometastases in 10-mm-diameter nodes could be achieved with FBP reconstruction.27 These predictions were generated from a system configuration with expanded beam illumination, no time restriction, a detection , and clinically feasible levels of fluorescence contrast (100 nM); therefore, verifying the potential for implementation of a simple, low-cost, and relatively quick system with the ability to detect and localize the smallest clinically significant metastases. The work presented here capitalizes on this finding for the development of a lymph node imaging protocol using angular restriction fluorescence OPT. In conjunction with this, we have been developing paired-agent strategies for microscopic sensitivity to cancer cells in lymph nodes both in vivo28 and ex vivo; however, its details are outside the scope of this paper. To demonstrate the advantage of scatter rejection in the angular domain for lymph node applications, fluorescence imaging was done on various porcine tissues using no restriction () and strict angular restriction (). Approximately 0.2-mm-diameter fluorescent agarose inclusions composed of IRDye 800CW (LI-COR Biosciences) were embedded as accurately as possible in the center of similar sized ( thick) lymph node, muscle, and fat tissues. The samples were suspended in transparent 1% agarose gel and placed on a motorized rotation stage for imaging on the in-house made angular restricted OPT system [schematic shown in Fig. 1(a)]. A 780-nm laser (FPL-02RFF1 Calmar Laser, Medocino, Palo Alto, California) was passed through a 10-nm-bandpass excitation filter (Chroma Technology, Rockingham, Vermont) and expanded using a Keplerian lens system [25- and 300-mm focal length lens (all lenses from ThorLabs, Newton, New Jersey)] to a beam waist of 2.4 cm, to illuminate the whole surface of the tissue from one direction. Fluorescent light exiting the sample was collected directly opposite the illumination using a telecentric lens system (100- to 25-mm focal length lens) to focus down the light through an aperture before reaching the camera (sCMOS; Quantalux, ThorLabs). A continuously variable iris diaphragm (CP20S, ThorLabs) served as an aperture to restrict detection NA and was positioned between the lenses, at the focal length of each yielding an for no restriction or for strict restriction. Emission light was filtered using a 45-nm notch filter centered at 780 nm (Chroma Technology). Camera exposure time was set to 1 s for images with no restriction and 5 s when strict restriction was implemented. All raw fluorescence signals in each setup were scaled independently and thresholded for visualization purposes such that 90% of the fluorescence range above the background is shown. <!-- named anchor --> Fig. 1 (a) System schematic. (b) Experimental protocol. Results for each of the different tissue types using no angular restriction and strict angular restriction are presented in Fig. 2. It can be seen that with a completely open iris diaphragm, the fluorescent signal was more diffuse than when scatter rejection was employed with a closed iris. Figures 2(c), 2(f), and 2(i) compare fluorescence intensity line profile plots for each system configuration (no versus strict angular restrictions) in lymph node tissue, fat tissue, and muscle tissue, respectively. Profiles were calculated as the average of 100 rows at 0 deg, 45 deg, 90 deg, and 125 deg across each image, for a total of four measurements (only the 0-deg profiles are plotted in Fig. 2); mean values of full width at half maximum (FWHM) ± standard deviation are summarized in Table 1. Lymph node tissue presented the greatest decrease () in FWHM when going from to 0.005, muscle tissue was least impacted ( decrease), and fat fell between the two, with a improvement. The results were consistent with what was expected based on tissue optical properties, namely scattering; where compared to soft tissue-like muscle and fat, lymph nodes are much lower scattering in nature (, , at 780 nm26). Reported values for piglet muscle are , , and , , measured at 630 and 632.8 nm, respectively.29 Human subcutaneous adipose tissue, meanwhile, had reduced scattering coefficients between 11.3 and at 780 nm.29 The anisotropy factor was not provided; however, using the average value for biological tissue (), an estimated average of could be deduced. Overall, an inverse relationship was found between scattering properties and resolution improvement with angular restriction; that is, as scattering increased, the difference in FWHM with and without angular restriction decreased. Muscle tissue revealed relatively similar results with and without scatter rejection, which can be attributed to its high “scattering power”—a parameter used to characterize the reduced scattering coefficient, , in Jacques’ in-depth review of biological tissue optical properties.30 In fact, muscle had reported a 2.7 times greater scattering power than fatty tissue. Fat, which had intermediate scattering properties, therefore showed improvements between that of lymph nodes and muscle. These findings support the conclusions of the previous simulation study26 in that angle restriction is an appropriate scatter rejection method specifically for lymph node applications because of its mesoscopic size and low scattering optical properties. While the resolution is obviously not sufficient to localize the inclusions from these single projections, based on the aforementioned simulation,27 it is expected that, upon tomography and reconstruction, they would be detected and localized with ease. <!-- named anchor --> Fig. 2 Porcine tissues (top row, lymph node; middle row, fat; and bottom row, muscle) embedded with a fluorescent inclusion. Tissues are ordered to represent expected levels of optical scattering increasing from top to bottom. Columns display: false-colored fluorescence images from a single tomographic view using (a), (d), (g) no angular restriction (); (b), (e), (h) strict angular restriction (). (c), (f), (i) Corresponding line profiles of normalized signal intensity. Tissue structures are outlined in white and scale bars are all 2 mm. Dashed lines indicate the center of 100 averaged rows of the intensity profiles plotted for zero and strict constriction in blue and red, respectively. <!-- named anchor --> Table 1 Values of FWHM of fluorescence intensity profiles for tissues with a fluorescent inclusion. Tissue FHWM (mm) NA=0.133 NA=0.005 Lymph node Fat Muscle To test this, experiments were conducted with a porcine lymph node metastases model [Fig. 1(b)]. A human breast cancer cell line (MDA-MB-231) with known elevated expression of epidermal growth factor receptor (EGFR) was transfected with green fluorescent protein (GFP) and grown in 3-D cell culture so that cells could form spheroids to mimic the architecture of metastases. The spheroids were allowed to grow to a diameter of . They were then stained for 60 min with a 100-nM solution of targeted fluorescent dye [IRDye 800DX-labeled cetuximab (an anti-EGFR antibody)] and rinsed with phosphate-buffered saline for 5 min before being implanted in two spots of lymph nodes excised from fresh porcine neck tissue acquired from a local butcher (). Inclusions were placed more superficially for whole node wide-field fluorescence imaging (Pearl, LI-COR, Lincoln, Nebraska) to verify successful implantation. The same imaging procedure described above was carried out, except only strict restriction was applied () and tomography was employed by capturing images in 5-deg intervals over 360 deg for a total of 72 tomographic views. The same collection range was applied for absorption images (no fluorescence filter). Reconstruction was done on both (fluorescence and absorption) data sets using FBP to create 3-D fluorescence maps of the micromets and to recreate the node volume for structural context. Two-dimensional (2-D) slices at the height of detected cells were also reconstructed. Following imaging, the samples were frozen-sectioned in OCT at -thick slices and... - 1 January 2016
- Published by Optica Publishing Group
- p. OW4D.6
Enhanced detection of early photons in time-domain optical tomography using dead-time characteristics of SPADs
A novel approach is presented for enhancing the detection of “early” photons in time-domain optical tomography utilizing the dead time effect of the detector to shift the dynamic range of it towards the first arrival photons.
- 1 January 2016
- Published by Optica Publishing Group
- p. OW4D.6
Enhanced detection of early photons in time-domain optical tomography using dead-time characteristics of SPADs
A novel approach is presented for enhancing the detection of “early” photons in time-domain optical tomography utilizing the dead time effect of the detector to shift the dynamic range of it towards the first arrival photons.
- 1 January 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 3 (1) , 011010
Full receiver operating characteristic curve estimation using two alternative forced choice studies
Task-based medical image quality is typically measured by the degree to which a human observer can perform a diagnostic task in a psychophysical human observer study. During a typical study, an observer is asked to provide a numerical score quantifying his confidence as to whether an image contains a diagnostic marker or not. Such scores are then used to measure the observers’ diagnostic accuracy, summarized by the receiver operating characteristic (ROC) curve and the area under ROC curve. These types of human studies are difficult to arrange, costly, and time consuming. In addition, human observers involved in this type of study should be experts on the image genre to avoid inconsistent scoring through the lengthy study. In two-alternative forced choice (2AFC) studies, known to be faster, two images are compared simultaneously and a single indicator is given. Unfortunately, the 2AFC approach cannot lead to a full ROC curve or a set of image scores. The aim of this work is to propose a methodology in which multiple rounds of the 2AFC studies are used to re-estimate an image confidence score (a.k.a. rating, ranking) and generate the full ROC curve. In the proposed approach, we treat image confidence score as an unknown rating that needs to be estimated and 2AFC as a two-player match game. To achieve this, we use the ELO rating system, which is used for calculating the relative skill levels of players in competitor-versus-competitor games such as chess. The proposed methodology is not limited to ELO, and other rating methods such as TrueSkill™, Chessmetrics, or Glicko can be also used. The presented results, using simulated data, indicate that a full ROC curve can be recovered using several rounds of 2AFC studies and that the best pairing strategy starts with the first round of pairing abnormal versus normal images (as in the classical 2AFC approach) followed by a number of rounds using random pairing. In addition, the proposed method was tested in a pilot human observer study. These pilot results indicate that three to five rounds of 2AFC studies require less human observer time than a full scoring study and that the re-estimated ROC curves and associated area under ROC curve values have high statistical agreement with the full scoring study.
- 1 January 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 3 (1) , 011010
Full receiver operating characteristic curve estimation using two alternative forced choice studies
Task-based medical image quality is typically measured by the degree to which a human observer can perform a diagnostic task in a psychophysical human observer study. During a typical study, an observer is asked to provide a numerical score quantifying his confidence as to whether an image contains a diagnostic marker or not. Such scores are then used to measure the observers’ diagnostic accuracy, summarized by the receiver operating characteristic (ROC) curve and the area under ROC curve. These types of human studies are difficult to arrange, costly, and time consuming. In addition, human observers involved in this type of study should be experts on the image genre to avoid inconsistent scoring through the lengthy study. In two-alternative forced choice (2AFC) studies, known to be faster, two images are compared simultaneously and a single indicator is given. Unfortunately, the 2AFC approach cannot lead to a full ROC curve or a set of image scores. The aim of this work is to propose a methodology in which multiple rounds of the 2AFC studies are used to re-estimate an image confidence score (a.k.a. rating, ranking) and generate the full ROC curve. In the proposed approach, we treat image confidence score as an unknown rating that needs to be estimated and 2AFC as a two-player match game. To achieve this, we use the ELO rating system, which is used for calculating the relative skill levels of players in competitor-versus-competitor games such as chess. The proposed methodology is not limited to ELO, and other rating methods such as TrueSkill™, Chessmetrics, or Glicko can be also used. The presented results, using simulated data, indicate that a full ROC curve can be recovered using several rounds of 2AFC studies and that the best pairing strategy starts with the first round of pairing abnormal versus normal images (as in the classical 2AFC approach) followed by a number of rounds using random pairing. In addition, the proposed method was tested in a pilot human observer study. These pilot results indicate that three to five rounds of 2AFC studies require less human observer time than a full scoring study and that the re-estimated ROC curves and associated area under ROC curve values have high statistical agreement with the full scoring study.