Long‐term impact of balloon postdilatation on neointimal formation: An experimental comparative study between second‐generation self‐expanding versus balloon‐expandable stent technologies
- 29 October 2013
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 83 (3) , 397-404
Abstract
Background Self‐expanding stents (SES) are reemerging as therapeutic alternatives to treat coronary artery disease. It has been proposed that SES can improve clinical outcomes by inducing less injury at implantation and achieving better vessel wall apposition. To date, little data exists comparing the vascular response to both methods of deployment in a controlled experimental setting. Objective To quantify differences in vascular injury and healing between second‐generation SES and balloon‐expandable stents (BES) and the effects of balloon postdilatation in a porcine coronary model. Methods Seventy‐five bare SES (AXXESS or vProtect) and 42 BES (Vision) were implanted in porcine coronaries. A subset of these received balloon postdilatation (SES + D = 22, BES + D = 20). Follow‐up was scheduled at 30 (BES = 10, BES + D = 6, SES = 19, SES + D = 8), 90 (BES = 6, BES + D = 8, SES = 19, SES + D = 8), and 180 days (BES = 6, BES + D = 6, SES = 15, SES + D = 6). Results In vivo imaging and histological analysis showed that neointimal formation peaks early (30 days) in BES. Conversely, for SES, the peak occurred later (90 days). However, the neointimal formation achieved in either group equalized at 180 days. For SES, postdilatation shortened the peak of neointimal formation to 30 days. Conversely, for BES, postdilatation delayed the peak of neointimal formation to 90 days. At 30 days, histology showed that SES had significantly less injury. However, at 90 days, injury scores tended to be higher for SES. By 180 days, injury scores were comparable between both groups. Conclusions The mechanism of stent expansion influences the degree of vascular injury and healing. The synergistic use of balloon postdilatation changes the dynamics of healing and may impact the potential beneficial effects inherent to SES technologies.Keywords
Funding Information
- Republic of Korea (A102065)
- Korea Healthcare Technology R&D Project
- Ministry of Health and Welfare
This publication has 19 references indexed in Scilit:
- Histopathologic evaluation of nitinol self-expanding stents in an animal model of advanced atherosclerotic lesionsEuroIntervention, 2010
- The use of self-expanding stents in coronary bifurcations and beyond: a paradigm revisitedEuroIntervention, 2009
- Novel self-expanding stent system for enhanced provisional bifurcation stenting: Examination by StentBoost and intravascular ultrasoundCatheterization and Cardiovascular Interventions, 2009
- Analysis of left main coronary artery bifurcation lesions treated with biolimus‐eluting DEVAX AXXESS plus nitinol self‐expanding stent: Intravascular ultrasound results of the AXXENT trialCatheterization and Cardiovascular Interventions, 2008
- Prospective randomized trial comparing a nitinol self-expanding coronary stent with low-pressure dilatation and a high-pressure balloon expandable bare metal stentHeart and Vessels, 2008
- Analysis of bifurcation lesions treated with novel drug‐eluting dedicated bifurcation stent system: Intravascular ultrasound results of the AXXESS PLUS trialCatheterization and Cardiovascular Interventions, 2007
- Coronary-Artery StentsNew England Journal of Medicine, 2006
- Self‐expanding stent deployment strategies may be the key to reducing in‐stent restenosisCatheterization and Cardiovascular Interventions, 2002
- Mechanical properties of metallic stents: How do these properties influence the choice of stent for specific lesions?CardioVascular and Interventional Radiology, 2000
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992