A method for calculating the dose length product from CT DICOM images
Authors:
- 1 March 2011
- journal article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84 (999) , 236-243
Abstract
The dosimetric calculations in CT examinations are currently based on two quantities: the volume weighted CT dose index (CTDI(vol)) and the dose-length product (DLP). The first quantity is dependent on the exposure factors, scan field of view, collimation and pitch factor selections, whereas the second is additionally dependent on the scan length. In this study a method for the calculation of these quantities from digital imaging and communication in medicine (DICOM) CT images is presented that allows an objective audit of patient doses. This method was based on software that has been developed to enable the automatic extraction of the DICOM header information of each image (relating to the parameters that affect the aforementioned quantities) into a spreadsheet with embedded functions for calculating the contribution of each image to the CTDI(vol) and DLP values. The applicability and accuracy of this method was investigated using data from actual examinations carried out in three different multislice CT scanners. These examinations have been performed with the automatic exposure control systems activated, and therefore the tube current and tube loading values varied during the scans. The calculated DLP values were in good agreement (±5%) with the displayed values. The calculated average CDTI(vol) values were in similar agreement with the displayed CTDI(vol) values but only for two of the three scanners. In the other scanner the displayed CTDI(vol) values were found to be overestimated by about 25%. As an additional application of this method the differences among the tube modulation techniques used by the three CT scanners were investigated. This method is a useful tool for radiation dose surveys.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of Measured and Calculated Skin Doses in CT-Guided Interventional ProceduresAmerican Journal of Roentgenology, 2008
- Patient dose evaluation by means of DICOM images for a direct radiography systemLa radiologia medica, 2008
- Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to PracticeRadioGraphics, 2008
- Results of a European dose survey for mammographyRadiation Protection Dosimetry, 2008
- CT-Guided Interventional Procedures without CT Fluoroscopy Assistance: Patient Effective Dose and Absorbed Dose ConsiderationsAmerican Journal of Roentgenology, 2007
- CT Dose Reduction and Dose Management Tools: Overview of Available OptionsRadioGraphics, 2006
- Patient dose reduction in CTBritish Journal of Radiology, 2005
- Patient dose in digital mammographyMedical Physics, 2004
- Primary radiation outside the imaged volume of a multislice helical CT scanBritish Journal of Radiology, 2002