Abstract
In this article, the concept of fusion topology is proposed to tackle the development trend and control issue of hybrid parallel multiconverter applications and to achieve better performance in transient and steady-state operations. Compared to previously fixed frequency compensation strategies, data-driven finite-state machine (FSM) control can determine which voltage source converter (VSC) dominates the operation or whether two VSCs operate simultaneously rather than giving the specific target operation to each VSC alone. The results are verified by a real-time digital simulator (RTDS) with the hardware-in-the-loop (HIL) experiments. The 20 kVA RTDS experimental results show that the transient time is shorter by 53.8%–85.7%, and power loss is smaller by 28.6%–78.3%, respectively, compared with the previous methods.
Funding Information
  • State Key Laboratory of Internet of Things for Smart Cities of the University of Macau (SKL-IOTSC(UM)-2021-2023)
  • Macau Science and Technology Fund, Macau SAR (FDCT0017/2022/A1)
  • Guangdong-Hong Kong-Macau Joint Laboratory for Smart Cities (EF008/IOTSC-YKV/2021/GDSTC)
  • Research Committee of University of Macau (MYRG2022-00035-FST)
  • Natural Science Foundation of Jilin Province (20220101171JC)
  • Hunan Youth Science and Technology Innovation Talents Program (2021RC3059)
  • International Postdoctoral Exchange Fellowship Program (YJ20220403)

This publication has 22 references indexed in Scilit: