Ziyi Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ziyi Bai has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Man-Chung Wong
University of Macau
7 shared publications - Da Xu
China University of Geosciences
4 shared publications - Ying Pang
Jilin University
4 shared publications - Zeng Xiang
State Key Laboratory of Internet of Things for Smart City, University of Macau, Macao, China
4 shared publications Chi-Kong Wong
State Key Laboratory of Internet of Things for Smart City, University of Macau, Macao, China
3 shared publications- Chi-Seng Lam
University of Macau
3 shared publications
Latest Publications
- Open Access
A PSO-BPNN-Based PI Parameter Tuning Strategy for the Inner Current Loop of a Vienna Rectifier with FPGA-Based Hardware-in-the-Loop Verification
To address the difficulty of conventional fixed-parameter PI controllers in the inner current loop of Vienna rectifiers in simultaneously achieving a fast dynamic response and overshoot suppression, this paper proposes a PSO-enhanced BPNN-based PI parameter-tuning strategy (PSO-BPNN-PI). The global search capability of particle swarm optimization (PSO) is exploited to optimize the initial weights of the back-propagation neural network (BPNN), mitigating the local-minima problem of random initialization and yielding a better-performing set of inner-loop PI parameters. On the equivalent current-loop model, the proposed strategy reduces the step-response overshoot to only 3.35%. On a full switching model of the Vienna rectifier, the proposed strategy is evaluated under steady-state operation, load disturbance, and filter-inductance variation and is further benchmarked against conventional PI, randomly initialized BPNN-PI, and LADRC controllers in dynamic disturbance tests. The proposed method achieves the lowest input-current THD and a balanced overall performance, while remaining competitive in tracking accuracy and maintaining its advantage over a wide inductance-mismatch range. Finally, a Hardware-in-the-Loop (HIL) platform with a heterogeneous CPU/FPGA architecture is established, on which the offline-optimized PI parameters are deployed; the results show stable tracking of the 750 V DC-bus voltage, rapid recovery from sudden load steps, and a well-balanced neutral-point voltage, confirming the engineering feasibility of the offline-optimized parameters.
Open AccessA PSO-BPNN-Based PI Parameter Tuning Strategy for the Inner Current Loop of a Vienna Rectifier with FPGA-Based Hardware-in-the-Loop Verification
To address the difficulty of conventional fixed-parameter PI controllers in the inner current loop of Vienna rectifiers in simultaneously achieving a fast dynamic response and overshoot suppression, this paper proposes a PSO-enhanced BPNN-based PI parameter-tuning strategy (PSO-BPNN-PI). The global search capability of particle swarm optimization (PSO) is exploited to optimize the initial weights of the back-propagation neural network (BPNN), mitigating the local-minima problem of random initialization and yielding a better-performing set of inner-loop PI parameters. On the equivalent current-loop model, the proposed strategy reduces the step-response overshoot to only 3.35%. On a full switching model of the Vienna rectifier, the proposed strategy is evaluated under steady-state operation, load disturbance, and filter-inductance variation and is further benchmarked against conventional PI, randomly initialized BPNN-PI, and LADRC controllers in dynamic disturbance tests. The proposed method achieves the lowest input-current THD and a balanced overall performance, while remaining competitive in tracking accuracy and maintaining its advantage over a wide inductance-mismatch range. Finally, a Hardware-in-the-Loop (HIL) platform with a heterogeneous CPU/FPGA architecture is established, on which the offline-optimized PI parameters are deployed; the results show stable tracking of the 750 V DC-bus voltage, rapid recovery from sudden load steps, and a well-balanced neutral-point voltage, confirming the engineering feasibility of the offline-optimized parameters.
- 7 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (2) , 5866-5875
Computing Optimal Resilience-Oriented Operation of Distribution Systems Considering Heterogenous Consumer-Side Microgrids
Mobile battery energy storage systems (MBESs), also called power-to-mobility, have been field-validated as backup generation resources. However, the role of multi-energy coordination towards resilient distribution systems (DSs) against large area disasters is still not yet involved. To cope with such challenges, this paper proposes a computing optimal resilient operation model for post-disaster microgrid-penetrated DS recovery based on the energy-to-mobility approach. In this model, mobile multi-energy storages (MMESs) are invested and routed based on their different transportation mobility, while DS with consumer-side biogas-solar-wind multi-energy microgrids are topologized by network reconfiguration. The coordinated resilient operation of different recovery actions of DS, MMESs, and consumer-side microgrids is a difficult optimization problem as results of its inherent nonconvexities, temporal-spatial mobility and strong multi-energy couplings. The original mixed-integer non-linear programming (MINLP) problem is thus equivalently linearized and reformulated into a mixed-integer linear programming (MILP) for computation performance improvement. The proposed methodology is benchmarked and performed on a modified radial DS with three consumer-side microgrids. Numerical studies demonstrate the effectiveness and superiority of the energy-to-mobility scheme over MBESs on system resilient level and economy.
- 7 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (2) , 5866-5875
Computing Optimal Resilience-Oriented Operation of Distribution Systems Considering Heterogenous Consumer-Side Microgrids
Mobile battery energy storage systems (MBESs), also called power-to-mobility, have been field-validated as backup generation resources. However, the role of multi-energy coordination towards resilient distribution systems (DSs) against large area disasters is still not yet involved. To cope with such challenges, this paper proposes a computing optimal resilient operation model for post-disaster microgrid-penetrated DS recovery based on the energy-to-mobility approach. In this model, mobile multi-energy storages (MMESs) are invested and routed based on their different transportation mobility, while DS with consumer-side biogas-solar-wind multi-energy microgrids are topologized by network reconfiguration. The coordinated resilient operation of different recovery actions of DS, MMESs, and consumer-side microgrids is a difficult optimization problem as results of its inherent nonconvexities, temporal-spatial mobility and strong multi-energy couplings. The original mixed-integer non-linear programming (MINLP) problem is thus equivalently linearized and reformulated into a mixed-integer linear programming (MILP) for computation performance improvement. The proposed methodology is benchmarked and performed on a modified radial DS with three consumer-side microgrids. Numerical studies demonstrate the effectiveness and superiority of the energy-to-mobility scheme over MBESs on system resilient level and economy.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1792-1805
A Multifunctional Inverter Integrated With Smart Substations for Grid-Connected and Island Operations
A power electronic-based smart substation should be developed to manipulate multifunctional operations, not only providing power supply and island operations but also manipulating power quality issues. This paper proposes a capacitive LC-coupling multifunctional inverter integrated with a primary tapped transformer (MFI-PTT) in a smart substation. The proposed MFI-PTT provides voltage support with island mode during a critical system disturbance or failed grid. In a normal condition, it ensures the active power transfer and current quality compensation. The operational mechanisms of multiple modes and power rating reduction analysis are mathematically revealed, further determining the required dc voltage, power rating, and power loss of converter. Furthermore, a comprehensive compensation control strategy based on multiple conditions is developed to perform different operational modes and their transitions with the consideration of the available capacity. Finally, the simulation and experimental results are presented to prove the effectiveness of the proposed MFIPTT on multifunctional operation performance and inverter rating reduction.
- 19 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1792-1805
A Multifunctional Inverter Integrated With Smart Substations for Grid-Connected and Island Operations
A power electronic-based smart substation should be developed to manipulate multifunctional operations, not only providing power supply and island operations but also manipulating power quality issues. This paper proposes a capacitive LC-coupling multifunctional inverter integrated with a primary tapped transformer (MFI-PTT) in a smart substation. The proposed MFI-PTT provides voltage support with island mode during a critical system disturbance or failed grid. In a normal condition, it ensures the active power transfer and current quality compensation. The operational mechanisms of multiple modes and power rating reduction analysis are mathematically revealed, further determining the required dc voltage, power rating, and power loss of converter. Furthermore, a comprehensive compensation control strategy based on multiple conditions is developed to perform different operational modes and their transitions with the consideration of the available capacity. Finally, the simulation and experimental results are presented to prove the effectiveness of the proposed MFIPTT on multifunctional operation performance and inverter rating reduction.
- 27 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Practical Impedance Matching Device and Parameter Design Method Under Nonlinear Current
Due to the requirement of country development, geological surveys must be developed from shallow to deep. Correspondingly, the output power of transient electromagnetic method (TEM) transmitter devices, the necessary power electronic equipment in the geological survey, has to be increased. However, in the process of improving output power, the reactive power of the load occupies a large portion of the output power. Then, this part of reactive power should be compensated by the impedance matching device. The biggest difference of impedance matching devices in the geological survey is the operating environment. The operating environment is under square nonlinear current. The square nonlinear current can be decomposed into a sum of several different frequency harmonics. Previously, almost all impedance matching devices are designed to compensate for the reactive power under a single frequency. There is seldom research to tell the users the method of how to match the several impedances under a sum of several different frequency harmonics. Thus, this paper proposed a topology to match impedance in nonlinear current environments first. Then, a design method is proposed to optimize the topology parameters for better performance. At last, a comparative simulation is given to tell the advantages of the proposed topology and its design method.
- 27 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Practical Impedance Matching Device and Parameter Design Method Under Nonlinear Current
Due to the requirement of country development, geological surveys must be developed from shallow to deep. Correspondingly, the output power of transient electromagnetic method (TEM) transmitter devices, the necessary power electronic equipment in the geological survey, has to be increased. However, in the process of improving output power, the reactive power of the load occupies a large portion of the output power. Then, this part of reactive power should be compensated by the impedance matching device. The biggest difference of impedance matching devices in the geological survey is the operating environment. The operating environment is under square nonlinear current. The square nonlinear current can be decomposed into a sum of several different frequency harmonics. Previously, almost all impedance matching devices are designed to compensate for the reactive power under a single frequency. There is seldom research to tell the users the method of how to match the several impedances under a sum of several different frequency harmonics. Thus, this paper proposed a topology to match impedance in nonlinear current environments first. Then, a design method is proposed to optimize the topology parameters for better performance. At last, a comparative simulation is given to tell the advantages of the proposed topology and its design method.
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (1) , 873-885
A Cascaded Multilevel Battery Energy Storage Based Parallel Dynamic Voltage Compensator for Medium Voltage Industrial Distribution Systems
This paper proposes a cascaded multilevel battery energy storage based parallel dynamic voltage compensator (DVC) for medium voltage industrial distribution systems. In this parallel DVC, fast switch is series-connected for voltage sag detection, and cascaded multilevel battery energy storage is parallel-connected for voltage support during the voltage sag period. According to the grid-side voltage sags or not, corresponding circuits and three-layer control strategies are developed. While the feedforward proportional–integral (PI) control method is adopted in the outer layer to track the ideal compensation voltage when the grid-side voltage sags, the ideal compensation current when the grid-side voltage does not sag is obtained through battery charging current as well as reactive power, harmonics, and negative sequence load current components. In order to cope with parameter differences in cascaded multilevel battery energy storage, the middle layer interphase and the inner layer intermodular state of charge (SOC) equalization control are adopted in two scenarios. Furthermore, the parallel DVC is quantitatively compared with series DVC in the aspect of required battery capacity, and their advantages and disadvantages are systematically analyzed. Case studies are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (1) , 873-885
A Cascaded Multilevel Battery Energy Storage Based Parallel Dynamic Voltage Compensator for Medium Voltage Industrial Distribution Systems
This paper proposes a cascaded multilevel battery energy storage based parallel dynamic voltage compensator (DVC) for medium voltage industrial distribution systems. In this parallel DVC, fast switch is series-connected for voltage sag detection, and cascaded multilevel battery energy storage is parallel-connected for voltage support during the voltage sag period. According to the grid-side voltage sags or not, corresponding circuits and three-layer control strategies are developed. While the feedforward proportional–integral (PI) control method is adopted in the outer layer to track the ideal compensation voltage when the grid-side voltage sags, the ideal compensation current when the grid-side voltage does not sag is obtained through battery charging current as well as reactive power, harmonics, and negative sequence load current components. In order to cope with parameter differences in cascaded multilevel battery energy storage, the middle layer interphase and the inner layer intermodular state of charge (SOC) equalization control are adopted in two scenarios. Furthermore, the parallel DVC is quantitatively compared with series DVC in the aspect of required battery capacity, and their advantages and disadvantages are systematically analyzed. Case studies are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.
- 17 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 11898-11910
A Centralized Battery Energy Storage-Based Medium-Voltage Multiwinding DVC for Balance and Unbalance Operations
In this article, we propose a centralized battery energy storage-based medium-voltage multiwinding dynamic voltage compensator (DVC) for balance and unbalance operations. In this topology, the compensation voltage is added to the grid side through the transformer, and the primary side of the transformer is shunted by multiple windings to support the voltage sag on the medium-voltage distribution systems. According to the symmetrical and asymmetrical grid-side voltage sags, the positive- and negative-sequence mathematical models of DVC as well as their voltage–current double closed-loop control strategies are developed. As for the dc bias caused by circulating current between the primary windings of each phase of the multiwinding transformer, circulating current suppression algorithm is added to the positive- and negative-sequence inner current loops. Simulation and experimental results are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.
- 17 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 11898-11910
A Centralized Battery Energy Storage-Based Medium-Voltage Multiwinding DVC for Balance and Unbalance Operations
In this article, we propose a centralized battery energy storage-based medium-voltage multiwinding dynamic voltage compensator (DVC) for balance and unbalance operations. In this topology, the compensation voltage is added to the grid side through the transformer, and the primary side of the transformer is shunted by multiple windings to support the voltage sag on the medium-voltage distribution systems. According to the symmetrical and asymmetrical grid-side voltage sags, the positive- and negative-sequence mathematical models of DVC as well as their voltage–current double closed-loop control strategies are developed. As for the dc bias caused by circulating current between the primary windings of each phase of the multiwinding transformer, circulating current suppression algorithm is added to the positive- and negative-sequence inner current loops. Simulation and experimental results are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 11853-11864
A Data-Driven Finite-State Machine-Based Control for Hybrid Parallel Multiconverters: Fusion Topology for High-Power Applications
In this article, the concept of fusion topology is proposed to tackle the development trend and control issue of hybrid parallel multiconverter applications and to achieve better performance in transient and steady-state operations. Compared to previously fixed frequency compensation strategies, data-driven finite-state machine (FSM) control can determine which voltage source converter (VSC) dominates the operation or whether two VSCs operate simultaneously rather than giving the specific target operation to each VSC alone. The results are verified by a real-time digital simulator (RTDS) with the hardware-in-the-loop (HIL) experiments. The 20 kVA RTDS experimental results show that the transient time is shorter by 53.8%–85.7%, and power loss is smaller by 28.6%–78.3%, respectively, compared with the previous methods.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (12) , 11853-11864
A Data-Driven Finite-State Machine-Based Control for Hybrid Parallel Multiconverters: Fusion Topology for High-Power Applications
In this article, the concept of fusion topology is proposed to tackle the development trend and control issue of hybrid parallel multiconverter applications and to achieve better performance in transient and steady-state operations. Compared to previously fixed frequency compensation strategies, data-driven finite-state machine (FSM) control can determine which voltage source converter (VSC) dominates the operation or whether two VSCs operate simultaneously rather than giving the specific target operation to each VSC alone. The results are verified by a real-time digital simulator (RTDS) with the hardware-in-the-loop (HIL) experiments. The 20 kVA RTDS experimental results show that the transient time is shorter by 53.8%–85.7%, and power loss is smaller by 28.6%–78.3%, respectively, compared with the previous methods.
- Open Access
- 5 January 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
A two-layer multi-energy management system for microgrids with solar, wind, and geothermal renewable energy
The inherent intermittency of high-penetrated renewable energy poses economic and reliable issues of microgrid energy management. This study proposes a two-layer predictive energy management system (PEMS) for high-renewable multi-energy microgrid (MEM). In this MEM, geothermal, solar, and wind energy is converted and conditioned for electricity, thermal, and gas supplies, in which multi-energy complementarities are fully exploited based on electrolytic thermos-electrochemical effects. The proposed microgrid multi-energy management is a complicated and cumbersome problem because of their increasingly tight energy couplings and uncertainties of renewable energy sources (RESs). This intractable problem is thus processed by means of a two-layer PEMS with different time scales, where the system operating costs are minimized in the upper layer and the renewable fluctuations are coped with in the lower layer. Simulation studies on a high-renewable MEM are provided to indicate its effectiveness and superiority over a single time scale scheme. Simulations results show that the operating cost can be reduced by 22.2% with high RESs accommodation.
- 5 January 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 10
Open AccessA two-layer multi-energy management system for microgrids with solar, wind, and geothermal renewable energy
The inherent intermittency of high-penetrated renewable energy poses economic and reliable issues of microgrid energy management. This study proposes a two-layer predictive energy management system (PEMS) for high-renewable multi-energy microgrid (MEM). In this MEM, geothermal, solar, and wind energy is converted and conditioned for electricity, thermal, and gas supplies, in which multi-energy complementarities are fully exploited based on electrolytic thermos-electrochemical effects. The proposed microgrid multi-energy management is a complicated and cumbersome problem because of their increasingly tight energy couplings and uncertainties of renewable energy sources (RESs). This intractable problem is thus processed by means of a two-layer PEMS with different time scales, where the system operating costs are minimized in the upper layer and the renewable fluctuations are coped with in the lower layer. Simulation studies on a high-renewable MEM are provided to indicate its effectiveness and superiority over a single time scale scheme. Simulations results show that the operating cost can be reduced by 22.2% with high RESs accommodation.
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (5) , 4320-4331
A Residential Miniboost Photovoltaic Inverter With Maximum Power Point Operation and Power Quality Compensation
Among the exiting multifunctional photovoltaic (PV) inverters (MPVIs), the main challenges are low efficiency, undesired harmonic emission, and weak compensation capability. In this article, a theoretical study via rotating phasor to the PV curves is first proposed to figure out the undesired harmonic emission puzzle in different PV inverters as well as to provide the foundation for PV inverters to achieve multifunction ability under varying load conditions. On the other hand, a single-phase time-sharing miniboost MPVI with different operation modes is proposed and operated under varying PV and load conditions in order to improve its efficiency and compensation capability without undesired harmonic emission. Corresponding control strategy and stability analysis are given. Finally, a 1.5-kW prototype is presented, benchmarked against harmonic emission issues, compensation capability, and efficiency. Experimental results clearly indicate that the proposed topology and control method can perform the active power injection and power quality compensation with better efficiency and avoiding harmonic emission into the grid dynamically.
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (5) , 4320-4331
A Residential Miniboost Photovoltaic Inverter With Maximum Power Point Operation and Power Quality Compensation
Among the exiting multifunctional photovoltaic (PV) inverters (MPVIs), the main challenges are low efficiency, undesired harmonic emission, and weak compensation capability. In this article, a theoretical study via rotating phasor to the PV curves is first proposed to figure out the undesired harmonic emission puzzle in different PV inverters as well as to provide the foundation for PV inverters to achieve multifunction ability under varying load conditions. On the other hand, a single-phase time-sharing miniboost MPVI with different operation modes is proposed and operated under varying PV and load conditions in order to improve its efficiency and compensation capability without undesired harmonic emission. Corresponding control strategy and stability analysis are given. Finally, a 1.5-kW prototype is presented, benchmarked against harmonic emission issues, compensation capability, and efficiency. Experimental results clearly indicate that the proposed topology and control method can perform the active power injection and power quality compensation with better efficiency and avoiding harmonic emission into the grid dynamically.