Influence of the prediction error of the first eye undergoing cataract surgery on the refractive outcome of the fellow eye
Open Access
- 1 October 2014
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 2177-2181
Abstract
Introduction: In addition to measurement errors, individual anatomical conditions could be made responsible for unexpected prediction errors in the determination of the correct intraocular lens power for cataract surgery. Obviously, such anatomical conditions might be relevant for both eyes. The purpose of this study was to evaluate whether the postoperative refractive error of the first eye has to be taken in account for the biometry of the second. Methods: In this retrospective study, we included 670 eyes of 335 patients who underwent phacoemulsification and implantation of a foldable intraocular lens in both eyes. According to the SRK/T formula, the postoperative refractive error of each eye was determined and compared with its fellow eye. Results: Of 670 eyes, 622 showed a postoperative refractive error within ±1.0 D (93%), whereas the prediction error was 0.5 D or less in 491 eyes (73%). The postoperative difference between both eyes was within 0.5 D in 71% and within 1.0 D in 93% of the eyes. Comparing the prediction error of an eye and its fellow eye, the error of the fellow eye was about half the value of the other. Conclusion: Our results imply that substitution of half of the prediction error of the first eye into the calculation of the second eye may be useful to reduce the prediction error in the second eye. However, prospective studies should be initiated to demonstrate an improved accuracy for the second eye’s intraocular lens power calculation by partial adjustment.Keywords
This publication has 20 references indexed in Scilit:
- Use of Fellow Eye Data in the Calculation of Intraocular Lens Power for the Second EyeOphthalmology, 2011
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Improved accuracy of intraocular lens power calculation with the Zeiss IOLMasterActa Ophthalmologica Scandinavica, 2006
- Partial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculationsEye, 2002
- Immersion A-scan compared with partial coherence interferometryJournal of Cataract & Refractive Surgery, 2002
- Improved prediction of intraocular lens power using partial coherence interferometryJournal of Cataract & Refractive Surgery, 2001
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Using the surgical result in the first eye to calculate intraocular lens power for the second eyeJournal of Cataract & Refractive Surgery, 1993
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 1992
- Errors in IOL Power Calculations for Axial High MyopiaOphthalmic Surgery, Lasers and Imaging Retina, 1991