GRGernot Roessler

Gernot Roessler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gernot Roessler has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predictability of success and open conjunctival revision rates in the subsequent eye after XEN45 Gel Stent implantation according to lens status

    by D. Kiessling, C. Rennings, M. Hild, A. Lappas, T.S. Dietlein, G.F. Roessler, R.A. Widder

    Purpose: To determine the predictability of success and the risk of open conjunctival revision in the subsequent eye after XEN45 Gel Stent implantation according to lens status. Methods: This was a retrospective single-centre study involving 132 eyes of 66 participants who had undergone intraocular pressure (IOP)-lowering XEN45 Gel Stent implantation, either as a standalone procedure in phakic and pseudophakic eyes or in combination with phacoemulsification. Successful surgery was defined by three scores: IOP at follow-up < 21 mmHg (score A) or < 18 mmHg (score B) and an IOP reduction > 20% or IOP ≤ 15 mmHg and an IOP reduction ≥ 40% (score C). In all scores, one open conjunctival revision was allowed, and additional repeat surgery was considered a failure. The predictability of success and revision rate depending on the outcome of the first eye were calculated using Bayes’ theorem. Results: IOP-lowering did not differ significantly between the first and second eyes. Success rates of standalone surgery in the second eye after successful surgery in the first eye significantly exceed rates after prior failure. For the combined procedure, the rates did not differ significantly. For score A, we determined a 76.6% chance of success following a prior success and a 57.9% chance, if prior surgery failed. The corresponding probabilities were 75% and 59.1% for score B, while 66.7% and 15.7% for score C, respectively. We calculated a 60% risk for revision surgery in the standalone phakic group. If the first eye was not revised, the risk of revision in the subsequent eye was 20%. The corresponding risks were 72.7% and 5% for the standalone procedure in pseudophakic patients and 38.4% and 41.7% for the combined procedure, respectively. Conclusion: The results of our study offer a tool to predict the outcome of subsequent eye surgeries based on either the outcome in the initial eye and the type of surgery performed, owing to the high predictive potential.


  • Open Access

    Intraocular lens power calculation for plus and minus lenses in high myopia using partial coherence interferometry

    by Matthias Fuest, Niklas Plange, David Kuerten, Hannah Schellhase, Babac A. E. Mazinani, Peter Walter, Stephan Kohnen, Randolf A. Widder, Gernot Roessler

    Purpose: We assessed the accuracy of lens power calculation in highly myopic patients implanting plus and minus intraocular lenses (IOL). Methods: We included 58 consecutive, myopic eyes with an axial length (AL) > 26.0 mm, undergoing phacoemulsification and IOL implantation following biometry using the IOLMaster 500. For lens power calculation, the Haigis formula was used in all cases. For comparison, refraction was back-calculated using the Barrett Universal II (Barrett), Holladay I, Hill-RBF (RBF) and SRK/T formulae. Results: The mean axial length was 30.17 ± 2.67 mm. Barrett (80%), Haigis (87%) and RBF (82%) showed comparable numbers of IOLs within 1 diopter (D) of target refraction. Visual acuity (BSCVA) improved (p < 0.001) from 0.60 ± 0.35 to 0.29 ± 0.29 logMAR (> 28-days postsurgery). The median absolute error (MedAE) of Barrett 0.49 D, Haigis 0.38, RBF 0.44 and SRK/T 0.44 did not differ. The MedAE of Haigis was significantly smaller than Holladay (0.75 D; p = 0.01). All median postoperative refractive errors (MedRE) differed significantly with the exception of Haigis to SRK/T (p = 0.6): Barrett − 0.33 D, Haigis 0.25, Holladay 0.63, RBF 0.04 and SRK/T 0.13. Barrett, Haigis, Holladay and RBF showed a tendency for higher MedAEs in their minus compared to plus IOLs, which only reached significance for SRK/T (p = 0.001). Barrett (p < 0.001) and RBF (p = 0.04) showed myopic, SRK/T (p = 002) a hyperopic shift in their minus IOLs. Conclusions: In highly myopic patients, the accuracies of Barrett, Haigis and RBF were comparable with a tendency for higher MedAEs in minus IOLs. Barrett and RBF showed myopic, SRK/T a hyperopic shift in their minus IOLs.


  • Open Access

    Ocular side effects of levitra® (vardenafil) – results of a double-blind crossover study in healthy male subjects

    by Gernot Roessler, Michael Vobig, Peter Walter, Babac Ae Mazinani

    Purpose: To determine ocular side effects of vardenafil with special regard to color vision and retinal function. Methods: This was a single center, randomized, double-blind, placebo-controlled, twofold crossover study with an administration of a single oral dose of two 20 mg tablets of BAY 38–9456 (vardenafil hydrochloride) or corresponding placebo in 24 healthy male subjects. Ocular investigations included Farnsworth–Munsell D100 color vision test, electroretinogram, and basic ophthalmological examinations like visual acuity, visual field, and slit-lamp of anterior segment and fundus. Results: Compared to placebo, administration of vardenafil hydrochloride lead to a temporary significant increase of Farnsworth–Munsell D100 total error score after 1 and 6 hours as well as in error lines 3 and 4 after 1 hour. Twenty-four hours after administration there was no significant alteration of total error score or of any error line. While latency of electroretinogram b-wave remained unaffected, amplitudes showed a significant decrease compared to placebo 1 hour following administration. While other ocular examinations did not reveal any differences in general some mild to moderate but no serious adverse events have been reported. Conclusion: Despite temporary changes in retinal function our study reports good tolerability of vardenafil in regard to ocular side effects.


  • Goldmann Applanation Tonometry Versus Dynamic Contour Tonometry After Vitrectomy

    by Nikolaos Mamas, Matthias Fuest, Antonios Koutsonas, Gernot Roessler, Babac E. Mazinani, Peter Walter, Niklas Plange

    The aim of the study was to investigate the agreement of intraocular pressure (IOP) measurement using dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in eyes after vitrectomy with intraocular gas endotamponade, in eyes after vitrectomy with no tamponade, and in controls. In this prospective comparative study IOP was measured with GAT and DCT in 41 eyes with gas endotamponade (sulfur hexafluoride 20%) 1 to 3 days after vitrectomy, in 32 postvitrectomy eyes with intraocular water, and in 46 control eyes with no history of glaucoma or intraocular surgery. Corneal pachymetry and axial length measurements were additionally performed. The mean difference between GAT and DCT (GAT-DCT) in gas-filled eyes was 3.1 mm Hg [SD=6.2 mm Hg], that in eyes after vitrectomy with no tamponade was 0.4 mm Hg (SD=4.8 mm Hg), and in control eyes was 0.4 mm Hg (SD=3.8 mm Hg). No significant correlation was found between the differences of GAT and DCT (GAT-DCT) and the mean IOP of GAT and DCT in water-filled eyes (r=-0.25, P=0.18) and control eyes (r=0.23, P=0.13), but a significant correlation was found in the gas-filled eyes (r=0.71, P<0.0001). A significant correlation between central corneal thickness and the mean difference of both methods was seen only in the control group (r=0.36, P=0.03). IOP as determined by DCT underestimates IOP in gas-filled eyes compared with GAT, as GAT values were on average 3.1 mm Hg higher compared with those of DCT. The extent of IOP underestimation using DCT increases with higher IOP values. In the group of eyes after vitrectomy and in normal eyes we found a generally good agreement between the 2 methods, although high interindividual discrepancies were present. Our findings suggest that the 2 devices should not be used interchangeably in IOP evaluation after vitrectomy with gas endotamponade, which remains a difficult challenge.


  • Open Access

    Influence of the prediction error of the first eye undergoing cataract surgery on the refractive outcome of the fellow eye

    by Gernot Roessler, Ludmilla Gorodezky, Babac Ae Mazinani, Niklas Plange, Peter Walter, Martin Wenzel

    Introduction: In addition to measurement errors, individual anatomical conditions could be made responsible for unexpected prediction errors in the determination of the correct intraocular lens power for cataract surgery. Obviously, such anatomical conditions might be relevant for both eyes. The purpose of this study was to evaluate whether the postoperative refractive error of the first eye has to be taken in account for the biometry of the second. Methods: In this retrospective study, we included 670 eyes of 335 patients who underwent phacoemulsification and implantation of a foldable intraocular lens in both eyes. According to the SRK/T formula, the postoperative refractive error of each eye was determined and compared with its fellow eye. Results: Of 670 eyes, 622 showed a postoperative refractive error within ±1.0 D (93%), whereas the prediction error was 0.5 D or less in 491 eyes (73%). The postoperative difference between both eyes was within 0.5 D in 71% and within 1.0 D in 93% of the eyes. Comparing the prediction error of an eye and its fellow eye, the error of the fellow eye was about half the value of the other. Conclusion: Our results imply that substitution of half of the prediction error of the first eye into the calculation of the second eye may be useful to reduce the prediction error in the second eye. However, prospective studies should be initiated to demonstrate an improved accuracy for the second eye’s intraocular lens power calculation by partial adjustment.


  • Open Access

    Dose-Response-Relationship between Number of Laser Burns and IOP Reduction in Cyclophotocoagulation: An Animal Study

    by Lars Wagenfeld, Hendrik Schwarzer, Gernot Roessler, Maren Klemm, Christos Skevas, Gisbert Richard, Oliver Zeitz

    Purpose. The relationship between number of laser burns of cyclophotocoagulation (CPC) and intraocular pressure (IOP) reduction is unknown. This animal model was established to reveal a possible dose-response-relationship between the number of applied laser burns and the IOP lowering effect.Methods. 30 chinchilla bastard rabbits were divided into 5 groups and treated with either 1, 5, 10, 20, or 30 CPC burns, respectively. IOP was followed up for 1 week. IOP reduction of a single 30-burn treatment was compared with a fractionated treatment (three sessions; one week in between; 10 burns/session).Results. IOP reduction increases nonlinearly with the number of CPC burns (max.-6.1±1.4 mmHg). Fractionated treatment shows similar IOP reduction with less complications and more constant results compared to single session treatment.Conclusions. The study reveals a complex relationship between IOP reduction and the number of CPC burns. Fractionated CPC gives comparable IOP reduction at a higher degree of safety.


  • Open Access

    Clinical Observations and Occurrence of Complications following Heavy Silicone Oil Surgery

    by Hendrik Schwarzer, Babac Mazinani, Niklas Plange, Matthias Fuest, Peter Walter, Gernot Roessler

    Purpose.To demonstrate development and complications in heavy silicone oil (HSO) surgery in 100 eyes following primary vitreoretinal surgery.Methods.100 eyes were included in this retrospective study that underwent vitreoretinal surgery using HSO as endotamponade. Indication diagnoses were retinal detachments(n=76), complicated macular holes (MH)(n=20), and others(n=4). HSO removal was performed after a mean period of 20.2 ± 19.0 weeks. In 18 eyes with poor functional prognosis the silicone oil remained permanently for stabilisation. Overall follow-up time was 35.9 ± 51.8 weeks.Results.The mean IOP before HSO surgery was 13.3 ± 5.6 mmHg and raised to an average maximum of 23.3 ± 8.5 mmHg postoperatively and decreased to 13.7 ± 7.2 mmHg after removal. Secondary IOP raise due to emulsification of the silicone oil endotamponade was seen in 29 eyes after 7.8 ± 4.5 weeks. Other complications being observed with HSO installed were persistent corneal erosion(n=3)and prolonged anterior chamber inflammation(n=29). In 13 eyes recurrent retinal detachments occurred during followup.Conclusions.According to our analysis HSO surgery might deliver satisfying results in complicated cases of ophthalmological surgery. However, potential complications should always be taken into account when making the decision if to use and when to remove HSO in complicated retinal surgery.


    • 1 April 2014
      • Vol. 9  (2) , 169-173
    Open Access

    Partial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes

    by Gernot F. Roessler, Yassin Djalali Talab, Thomas S. Dietlein, Sven Dinslage, Niklas Plange, Peter Walter, Babac Ae Mazinani

    To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements and SNR were analyzed and compared among the two study groups. Axial length measurements were feasible in 46 of 52 (88.5%) highly myopic eyes and in 41 of 45 (91.1%) eyes with normal axial length. To achieve two reliable axial length values with SNR ≥2, a mean number of 2.06±0.25 measurements was necessary in myopic eyes and 2.10±0.37 in emmetropic counterparts. Mean SNR after two measurements was 4.98±2.44 in myopic eyes versus 5.56±2.32 in control eyes. Even though successful measurement was independent of preoperative visual acuity, patients with visual acuity better than 20/63 showed significantly higher SNR values. Partial coherence laser interferometry shows satisfying feasibility and good signal quality for axial length determination in highly myopic eyes with stable retinal condition and clear media.


  • Open Access

    Development of very large electrode arrays for epiretinal stimulation (VLARS)

    by Florian Waschkowski, Stephan Hesse, Anne Christine Rieck, Tibor Lohmann, Claudia Brockmann, Thomas Laube, Norbert Bornfeld, Gabriele Thumann, Peter Walter, Wilfried Mokwa, et al.

    Background: Retinal implants have been developed to treat blindness causing retinal degenerations such as Retinitis pigmentosa (RP). The retinal stimulators are covering only a small portion of the retina usually in its center. To restore not only central vision but also a useful visual field retinal stimulators need to cover a larger area of the retina. However, large area retinal stimulators are much more difficult to implant into an eye. Some basic questions concerning this challenge should be answered in a series of experiments. Methods: Large area retinal stimulators were fabricated as flexible multielectrode arrays (MEAs) using silicon technology with polyimide as the basic material for the substrate. Electrodes were made of gold covered with reactively sputtered iridium oxide. Several prototype designs were considered and implanted into enucleated porcine eyes. The prototype MEAs were also used as recording devices. Results: Large area retinal stimulator MEAs were fabricated with a diameter of 12 mm covering a visual angle of 37.6° in a normal sighted human eye. The structures were flexible enough to be implanted in a folded state through an insertion nozzle. The implants could be positioned onto the retinal surface and fixated here using a retinal tack. Recording of spontaneous activity of retinal neurons was possible in vitro using these devices. Conclusions: Large flexible MEAs covering a wider area of the retina as current devices could be fabricated using silicon technology with polyimide as a base material. Principal surgical techniques were established to insert such large devices into an eye and the devices could also be used for recording of retinal neural activity.


  • Angiographic findings following tack fixation of a wireless epiretinal retina implant device in blind RP patients

    by Gernot Roessler, The EPIRET Group, Thomas Laube, Claudia Brockmann, Thomas Kirschkamp, Babac Mazinani, Johannes Menzel-Severing, Norbert Bornfeld, Peter Walter