Open‐circuit fault diagnosis method for the T‐type inverter based on analysis of the switched bridge voltage
Authors:
Open Access
- 1 February 2019
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (2) , 295-302
Abstract
Multilevel inverter topologies have been widely used in applications of wide‐power range. Therefore, fault diagnosis of such circuits is becoming more and more important. The T‐type topology, which is one of many multilevel topologies, has an advantage in terms of efficiency compared to the neutral‐point‐clamped type. This study proposes a new diagnosis method of an open‐circuit (OC) fault for a three‐level T‐type inverter (3LT 2 I). The proposed method is achieved by measuring the bridge voltage and its duration time. The bridge voltage includes information of switching states of 3LT 2 I but not affected by the load. First, according to polarity of the reference voltage and corresponding phase current, working period of the 3LT 2 I is divided into four working regions. Then, the bridge voltage is analysed in detail when an OC fault occurs in different working regions. At last, a fault diagnosis circuit is designed to achieve automatic diagnosis for the OC fault. Simulation and experimental results show that the proposed method can identify the faulty switch exactly and quickly.Keywords
Funding Information
- Natural Science Foundation of Ningbo Municipality (2016A610222)
This publication has 22 references indexed in Scilit:
- Single‐phase cascaded H‐bridge multi‐level active power filter based on direct current control in AC electric railway applicationIET Power Electronics, 2017
- Method to diagnose open‐circuit faults in active power switches and clamp‐diodes of three‐level neutral‐point clamped invertersIET Electric Power Applications, 2016
- Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine SystemsIEEE Transactions on Industry Applications, 2014
- Fault diagnostic algorithm for three‐level neutral point clamped AC motor drives, based on the average current Park's vectorIET Power Electronics, 2014
- An Open-Switch Fault Detection Method and Tolerance Controls Based on SVM in a Grid-Connected T-Type Rectifier With Unity Power FactorIEEE Transactions on Industrial Electronics, 2014
- Survey of Fault-Tolerance Techniques for Three-Phase Voltage Source InvertersIEEE Transactions on Industrial Electronics, 2014
- Short-Circuit Fault Diagnosis for Three-Phase Inverters Based on Voltage-Space PatternsIEEE Transactions on Industrial Electronics, 2014
- Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter SystemsIEEE Transactions on Industry Applications, 2013
- Experimental verification of multilevel inverter-based standalone power supply for low-voltage and low-power applicationsIET Power Electronics, 2012
- A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power InvertersIEEE Transactions on Industry Applications, 2009