Danjiang Chen
Danjiang Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Shaozhong Zhang
College of Information and Intelligence Engineering, Zhejiang Wanli University, China
2 shared publicationsYutian Liu
College of Information and Intelligence Engineering, Zhejiang Wanli University, China
2 shared publications- Hao Li
Xidian University
1 shared publication - Jianhua Zhou
School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, China
1 shared publication Keyu Dong
ZheJiang Sinobloom Controls Co., Ltd,RD Department,Ningbo,China
1 shared publication- Liyuan Zheng
College of Information and Intelligence Engineering, Zhejiang Wanli University, No. 8, South Qian Hu Road, Ningbo, Zhejiang, China 315100
1 shared publication
Latest Publications
- 17 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4356-4359
Research on Distributed Temperature Monitoring System for Gasifier Based on Optical Fiber Sensors
Monitoring the wall temperature of gasifiers in the chemical industry can not only timely detect hot spots and avoid accidents, but also predict the thinning degree of refractory bricks and optimize maintenance cycles. In order to achieve distributed temperature measurement, this paper studies a distributed temperature monitoring system for gasifiers based on optical fiber sensors. The system includes four parts: on-site high-temperature resistant temperature sensors, network transmission system, temperature monitoring host, and temperature monitoring analysis software platform. The experimental results indicate that this system can achieve real-time measurement of the temperature in different areas of the gasifier wall.
- 17 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4356-4359
Research on Distributed Temperature Monitoring System for Gasifier Based on Optical Fiber Sensors
Monitoring the wall temperature of gasifiers in the chemical industry can not only timely detect hot spots and avoid accidents, but also predict the thinning degree of refractory bricks and optimize maintenance cycles. In order to achieve distributed temperature measurement, this paper studies a distributed temperature monitoring system for gasifiers based on optical fiber sensors. The system includes four parts: on-site high-temperature resistant temperature sensors, network transmission system, temperature monitoring host, and temperature monitoring analysis software platform. The experimental results indicate that this system can achieve real-time measurement of the temperature in different areas of the gasifier wall.
- Open Access
- 15 November 2022
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 71 (4) , 931-948
Fault-tolerant control for three-phase three-level T-type inverters with a redundant leg
Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
- 15 November 2022
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 71 (4) , 931-948
Open AccessFault-tolerant control for three-phase three-level T-type inverters with a redundant leg
Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
- Open Access
- 25 March 2021
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 70 (1) , 73-87
Fault diagnosis of T-type three-level inverter based on bridge voltages
Multilevel inverters have been widely used in various occasions due to their advantages such as lowharmonic content of the outputwaveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, and a diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when an open-circuit fault of the device occurred, and the effect on the circuit switching states and the bridge voltages were analyzed. Then comprehensively considered the bridge voltages, and proposed a fault diagnosis method for a T-type three-level inverter based on specific fault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of the inverter device, and has the advantage of being easy to implement.
- 25 March 2021
- Published by Polish Academy of Sciences Chancellery in Archives of Electrical Engineering
- Vol. 70 (1) , 73-87
Open AccessFault diagnosis of T-type three-level inverter based on bridge voltages
Multilevel inverters have been widely used in various occasions due to their advantages such as lowharmonic content of the outputwaveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, and a diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when an open-circuit fault of the device occurred, and the effect on the circuit switching states and the bridge voltages were analyzed. Then comprehensively considered the bridge voltages, and proposed a fault diagnosis method for a T-type three-level inverter based on specific fault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of the inverter device, and has the advantage of being easy to implement.
- Open Access
- 1 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (2) , 295-302
Open‐circuit fault diagnosis method for the T‐type inverter based on analysis of the switched bridge voltage
Multilevel inverter topologies have been widely used in applications of wide‐power range. Therefore, fault diagnosis of such circuits is becoming more and more important. The T‐type topology, which is one of many multilevel topologies, has an advantage in terms of efficiency compared to the neutral‐point‐clamped type. This study proposes a new diagnosis method of an open‐circuit (OC) fault for a three‐level T‐type inverter (3LT 2 I). The proposed method is achieved by measuring the bridge voltage and its duration time. The bridge voltage includes information of switching states of 3LT 2 I but not affected by the load. First, according to polarity of the reference voltage and corresponding phase current, working period of the 3LT 2 I is divided into four working regions. Then, the bridge voltage is analysed in detail when an OC fault occurs in different working regions. At last, a fault diagnosis circuit is designed to achieve automatic diagnosis for the OC fault. Simulation and experimental results show that the proposed method can identify the faulty switch exactly and quickly.
- 1 February 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (2) , 295-302
Open AccessOpen‐circuit fault diagnosis method for the T‐type inverter based on analysis of the switched bridge voltage
Multilevel inverter topologies have been widely used in applications of wide‐power range. Therefore, fault diagnosis of such circuits is becoming more and more important. The T‐type topology, which is one of many multilevel topologies, has an advantage in terms of efficiency compared to the neutral‐point‐clamped type. This study proposes a new diagnosis method of an open‐circuit (OC) fault for a three‐level T‐type inverter (3LT 2 I). The proposed method is achieved by measuring the bridge voltage and its duration time. The bridge voltage includes information of switching states of 3LT 2 I but not affected by the load. First, according to polarity of the reference voltage and corresponding phase current, working period of the 3LT 2 I is divided into four working regions. Then, the bridge voltage is analysed in detail when an OC fault occurs in different working regions. At last, a fault diagnosis circuit is designed to achieve automatic diagnosis for the OC fault. Simulation and experimental results show that the proposed method can identify the faulty switch exactly and quickly.