The radioprotective effect of the Cathpax® AIR cabin during interventional cardiology procedures
- 12 May 2021
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (4) , E523-E530
Abstract
Background The use of ionizing radiation during cardiac catheterization interventions adversely impacts the medical staff. Traditional radiation protection equipment is only partially effective. The Cathpax® radiation protection cabin (RPC) has proven to significantly reduce radiation exposure in electrophysiological and neuroradiology interventions. Our objective was to analyze whether the Cathpax® RPC reduces radiation dose in coronary and cardiac structural interventions in unselected real‐world procedures. Methods and Results In this nonrandomized all‐comers prospective study, 119 consecutive cardiac interventional procedures were alternatively divided into two groups: the RPC group (n = 59) and the non‐RPC group (n = 60). No significant changes in the characteristics of patients and procedures, average contrast volume, air kerma (AK), dose area‐product (DAP) and fluoroscopy time between both groups were apparent. In the RPC group, the first‐operator relative radiation exposure was reduced by 78% at the chest and by 70% at the wrist. This effect was consistent during different types of procedures including complex percutaneous interventions and structural procedures. Conclusions Our study demonstrates, for the first time, that the Cathpax® cabin significantly and efficiently reduces relative operator radiation exposure during different types of interventional procedures, confirming its feasibility in a real‐world setting.Keywords
This publication has 27 references indexed in Scilit:
- Usefulness of Pelvic Radiation Protection Shields During Transfemoral Procedures—Operator and Patient ConsiderationsThe American Journal of Cardiology, 2018
- Innovations in Radiation Safety During Cardiovascular CatheterizationCirculation, 2018
- Efficacy of the RADPAD Protection Drape in Reducing Operators’ Radiation Exposure in the Catheterization LaboratoryCirculation: Cardiovascular Interventions, 2017
- Risk of cataract among interventional cardiologists and catheterization lab staff: A systematic review and meta‐analysisCatheterization and Cardiovascular Interventions, 2017
- Optimizing Radiation Safety in the Cardiac Catheterization LaboratoryCatheterization and Cardiovascular Interventions, 2015
- Radiation Dose Reduction in the Cardiac Catheterization Laboratory Utilizing a Novel ProtocolJACC: Cardiovascular Interventions, 2014
- Significant reduction of radiation exposure using a protection cabin for electrophysiological proceduresMedical Imaging and Radiology, 2013
- Radiation effects in fluoroscopically guided cardiac interventions—keeping them under controlInternational Journal of Cardiology, 2006
- Radiation in the cardiac catheter laboratoryHeart, 2005
- ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular proceduresJACC, 2004