Numerical Study of the Uniformity of Balloon-Expandable Stent Deployment
- 1 April 2008
- journal article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 130 (2) , 021018
Abstract
Stents are small tubelike structures, implanted in coronary and peripheral arteries to reopen narrowed vessel sections. This endovascular intervention remains suboptimal, as the success rate is limited by restenosis. This renarrowing of a stented vessel is related to the arterial injury caused by stent-artery and balloon-artery interactions, and a local subsequent inflammatory process. Therefore, efforts to optimize the stent deployment remain very meaningful. Several authors have studied with finite element modeling the mechanical behavior of balloon-expandable stents, but none of the proposed models incorporates the folding pattern of the balloon. We developed a numerical model in which the CYPHER™ stent is combined with a realistic trifolded balloon. In this paper, the impact of several parameters such as balloon length, folding pattern, and relative position of the stent with respect to the balloon catheter on the free stent expansion has been investigated. Quantitative validation of the modeling strategy shows excellent agreement with data provided by the manufacturer and, therefore, the model serves as a solid basis for further investigations. The parametric analyses showed that both the balloon length and the folding pattern have a considerable influence on the uniformity and symmetry of the transient stent expansion. Consequently, this approach can be used to select the most appropriate balloon length and folding pattern for a particular stent design in order to optimize the stent deployment. Furthermore, it was demonstrated that small positioning inaccuracies may change the expansion behavior of a stent. Therefore, the placement of the stent on the balloon catheter should be accurately carried out, again in order to decrease the endothelial damage.Keywords
This publication has 18 references indexed in Scilit:
- Review of Randomized Clinical Trials of Drug-Eluting Stents for the Prevention of In-Stent Restenosis††All study acronyms used in this review are defined in Table 1.The American Journal of Cardiology, 2006
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Coronary-Artery StentsNew England Journal of Medicine, 2006
- Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised Basel Stent Kosten Effektivitäts Trial (BASKET)The Lancet, 2005
- Randomized comparison of coronary stent implantation and balloon angioplasty in the treatment of de novo coronary artery lesions (START)JACC, 1999
- Balloon-Artery Interactions During Stent PlacementCirculation Research, 1999
- Pathology of Acute and Chronic Coronary Stenting in HumansCirculation, 1999
- Luminal loss and site of restenosis after Palmaz-Schatz coronary stent implantationThe American Journal of Cardiology, 1995
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994