PMPeter Mortier

Peter Mortier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Mortier has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • TCT-785 Low implantation depth during TAVR increases the pressure exerted on the atrioventricular conduction system: a biomechanical analysis

    by Giorgia Rocatello, Nahid El Faquir, Patrick Segers, Peter Mortier, Peter de Jaegere


  • Finite element analysis of side branch access during bifurcation stenting

    by Peter Mortier, Matthieu De Beule, Denis Van Loo, Benedict Verhegghe, Pascal Verdonck

    Stent implantation has become a widely accepted endovascular intervention for the treatment of stenosed arteries. This minimally invasive technique has shown excellent results in unbranched arteries. However, stenting bifurcation lesions remains a challenge in coronary intervention as it is associated with a lower success rate. Many different techniques have been proposed in medical practice but all the suggested methodologies have specific limitations. Numerical simulations may help to understand and eliminate the shortcomings of current clinical techniques and devices. In this study, one of the currently applied techniques is analysed which involves the implantation of a stent in the main branch, followed by subsequent inflation of a balloon through the side of the stent. This improves the side branch patency and provides access to the side branch for later stent implantations. The impact of using different balloon sizes and stent designs was investigated. The stent cell through which the balloon is inflated increases considerably and as intuitively expected, using a larger balloon results in a larger opening. Furthermore, it was observed that this procedure may compromise the downstream main branch lumen. These observations correspond well with previously reported results, which were based on in vitro studies. The added value of the proposed numerical model is the ability to study many different techniques/stents, without the need for various expensive stent samples.


  • Comparison of drug-eluting stent cell size using micro-CT: important data for bifurcation stent selection

    by Peter Mortier, Denis Van Loo, Matthieu De Beule, Patrick Segers, Yves Taeymans, Pascal Verdonck, Benedict Verhegghe

    The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)


  • Automated generation of a finite element stent model

    by Peter Mortier, Matthieu De Beule, Denis Van Loo, Bert Masschaele, Pascal Verdonck, Benedict Verhegghe

    Numerical simulations have proven to be a valuable tool to investigate the mechanical behavior of stents. These computer models require a considerable amount of preprocessing and computational effort and consequently there is a continuous need for accurate simplifications and automation. For example, it was recently shown that using beam elements instead of solid elements results in a significant speed up of stent simulations. However, the currently applied techniques to create a finite element mesh starting from stent samples remain time-consuming. We present a semi-automated strategy to obtain an accurate finite element beam mesh from a stent sample. The method consists of two steps: (1) A triangulated surface representation of the stent geometry is obtained from micro CT images. (2) Subsequently, a beam mesh is automatically generated by computing the centerline. The method is time-effective and results in an accurate 3D stent model as demonstrated for the MULTI-LINK Vision™ stent.


  • A MICROTOMOGRAPHY SETUP FOR THE VALIDATION OF NUMERICAL STENT EXPANSION IN MOCK ARTERIES

    by Denisv Van Loo, Matthieu De Beule, Peter Mortier, Bert Masschaele, Luc Van Hoorebeke, Benedict Verhegghe, Pascal Verdonck

  • MECHANICS OF NEW GENERATION BRAIDED WIRE STENTS

    by Matthieu De Beule, Peter Mortier, Denis Van Loo, Benedict Verhegghe, Rudy Van Impe, Pascal Verdonck

  • Numerical Study of the Uniformity of Balloon-Expandable Stent Deployment

    by P. Mortier, M. De Beule, S. G. Carlier, R. Van Impe, B. Verhegghe, P. Verdonck

    Stents are small tubelike structures, implanted in coronary and peripheral arteries to reopen narrowed vessel sections. This endovascular intervention remains suboptimal, as the success rate is limited by restenosis. This renarrowing of a stented vessel is related to the arterial injury caused by stent-artery and balloon-artery interactions, and a local subsequent inflammatory process. Therefore, efforts to optimize the stent deployment remain very meaningful. Several authors have studied with finite element modeling the mechanical behavior of balloon-expandable stents, but none of the proposed models incorporates the folding pattern of the balloon. We developed a numerical model in which the CYPHER™ stent is combined with a realistic trifolded balloon. In this paper, the impact of several parameters such as balloon length, folding pattern, and relative position of the stent with respect to the balloon catheter on the free stent expansion has been investigated. Quantitative validation of the modeling strategy shows excellent agreement with data provided by the manufacturer and, therefore, the model serves as a solid basis for further investigations. The parametric analyses showed that both the balloon length and the folding pattern have a considerable influence on the uniformity and symmetry of the transient stent expansion. Consequently, this approach can be used to select the most appropriate balloon length and folding pattern for a particular stent design in order to optimize the stent deployment. Furthermore, it was demonstrated that small positioning inaccuracies may change the expansion behavior of a stent. Therefore, the placement of the stent on the balloon catheter should be accurately carried out, again in order to decrease the endothelial damage.